• No results found

dc fault ride-through capability

DC fault ride through capability and STATCOM operation of a HVDC hybrid voltage source converter

DC fault ride through capability and STATCOM operation of a HVDC hybrid voltage source converter

... the DC fault ride through capability and new STATCOM modes of operation for the recently published Alternate Arm Converter (AAC), intended for the HVDC ...and fault ride ...

16

Hybrid cascaded modular multilevel converter with DC fault ride-through capability for HVDC transmission system

Hybrid cascaded modular multilevel converter with DC fault ride-through capability for HVDC transmission system

... block dc faults with reduced semiconductor losses compared to [13]; however, the direct switches composed of series connected IGBTs are still ...ac fault ride-through capability and can ...

10

Pre-charging and DC fault ride-through of hybrid MMC based HVDC systems

Pre-charging and DC fault ride-through of hybrid MMC based HVDC systems

... pole-to-pole dc fault is applied (stage V). The dc voltage quickly drops to zero, the hybrid MMC reduces the active power to zero accordingly and meanwhile, it supplies ...the dc fault, ...

9

Fault ride-through enhancement of PMSG wind turbines with DC microgrids using resistive-type SFCL

Fault ride-through enhancement of PMSG wind turbines with DC microgrids using resistive-type SFCL

... the DC-link. On the other hand, superconducting fault current limiter (SFCL) was used in [10] to improve FRT capability of PMSG connected to AC grids through minimizing the mismatch between ...

5

The impact of MVDC upon conventional distance protection schemes in hybrid ac-dc distribution networks

The impact of MVDC upon conventional distance protection schemes in hybrid ac-dc distribution networks

... Two main studies are presented in this paper. The first determines whether the reach of a distance protection relay is changed should an embedded dc link with fault ride through ...

6

Ride-through-fault capabilities of DFIG wind farm connected to a VSC station during a DC fault

Ride-through-fault capabilities of DFIG wind farm connected to a VSC station during a DC fault

... RTF capability [ ...a fault on the AC network, while carrying out a successful RTF of the DFIG wind farm, thus proving the efficiency of the VSC based power transmission for grid-code compliance ...RTF ...

5

Low Voltage Ride through Control Capability of a Large Grid Connected PV System Combining DC Chopper and Current Limiting Techniques

Low Voltage Ride through Control Capability of a Large Grid Connected PV System Combining DC Chopper and Current Limiting Techniques

... the dc-link capacitor during normal operation in order to extract the maximum power from the PV ...a fault occurs, an imbalance occurs between the incoming power from the PV side and the power delivered to ...

18

Non controlled Fault Current Limiter to Improve Fault Ride through Capability of DFIG Based Wind Turbine

Non controlled Fault Current Limiter to Improve Fault Ride through Capability of DFIG Based Wind Turbine

... FRT capability improvement in the DFIG-based wind turbine. The fault happens at t=3s, and continues for ...the DC chopper operates when the DC link voltage reaches to threshold value of ...the ...

5

Low voltage ride through enhancement of DFIG based wind turbine using {DC} link switchable resistive type fault current limiter

Low voltage ride through enhancement of DFIG based wind turbine using {DC} link switchable resistive type fault current limiter

... The performance of the three types of bridge types FCL (BTFCL) is evaluated in [23] to enhance the LVRT capability of the DFIG. The first type of the BTFCL is introduced a basic topology. However, when the diode ...

26

Fault Ride-Through Capability Improve for Fixed Speed Wind Turbine by using Bridge- type Fault Current Limiter

Fault Ride-Through Capability Improve for Fixed Speed Wind Turbine by using Bridge- type Fault Current Limiter

... the fault ride-through of induction generators (IGs) by ...after fault happening ...bridge-type fault current limiter (FCL) with discharge resistor is used for solving trouble of the ...

8

Comparison and analysis of fault ride through capability for grid integrated Photovoltaic system with Continuous mixed P-Norm, Fuzzy and Proportional-Resonant Controllers

Comparison and analysis of fault ride through capability for grid integrated Photovoltaic system with Continuous mixed P-Norm, Fuzzy and Proportional-Resonant Controllers

... grid through double circuit transmission lines and three- phase step up ...the DC-DC Boost Converter and Grid side inverter are used to integrate the PV system with the electrical ...

10

Review of different Fault Ride through (FRT) Control Strategies for a DFIG Wind Turbine

Review of different Fault Ride through (FRT) Control Strategies for a DFIG Wind Turbine

... LVRT capability improvement of WTs based on fixed-speed wind turbines, which is relatively a new concept in maintaining voltage profile of the wind power ...Voltage Ride Through is an important ...

17

Distributed PLL-based control of offshore wind turbines connected with diode-rectifier based HVDC systems

Distributed PLL-based control of offshore wind turbines connected with diode-rectifier based HVDC systems

... plug-and-play capability when offline WTs are synchronized to the offshore ...To ride-through an onshore fault, an active dc voltage control method is proposed for the onshore HVDC MMC ...

9

Improving fault ride through of three phase voltage source inverter during symmetrical fault using DC link fault current limiter

Improving fault ride through of three phase voltage source inverter during symmetrical fault using DC link fault current limiter

... have fault ride- through (FRT) ...a DC link fault current limiter (DLFCL) based VSI FRT scheme to improve its FRT ...the DC side of the VSI to limit the output current during ...

5

A Review on Fault Current Limiting Devices to Enhance Fault Ride-through Capability of Doubly Fed Induction Generator Based Wind turbine

A Review on Fault Current Limiting Devices to Enhance Fault Ride-through Capability of Doubly Fed Induction Generator Based Wind turbine

... pre- fault active power of the hybrid generation units and fault location have been taken into ...the DC link voltage deviation of the PV generator, and the load angle deviation of the ...the ...

23

Fault Ride Through Capability Enhancement of PV System with Voltage Support Control Strategy

Fault Ride Through Capability Enhancement of PV System with Voltage Support Control Strategy

... , the magnitude of PCC voltage be- comes maximum. However, when the output current of the inverter reaches the maximum, as the control system output reactive power prior to active power and the ac- tive power generated ...

5

Vol 2, No 12 (2014)

Vol 2, No 12 (2014)

... to ride-through dc side ...acting dc circuit breaker, with considerably high let-through current to tolerate the high dc fault discharge current that may flow in the ...

7

Active Power Tracking Control Strategy to Suppress DC-Link Voltage Rising with Enhanced Fault Ride-Through Capability using Superconducting Fault Current Limiter

Active Power Tracking Control Strategy to Suppress DC-Link Voltage Rising with Enhanced Fault Ride-Through Capability using Superconducting Fault Current Limiter

... Active Power Tracking Control (APTC) for Suppression of DC-link Voltage Rising 180. As discussed in the introduction above, according to the FRT, when an abnormal voltage in the[r] ...

14

Optimum resistive type fault current limiter: An efficient solution to achieve maximum fault ride through capability of fixed speed wind turbines during symmetrical and asymmetrical grid faults

Optimum resistive type fault current limiter: An efficient solution to achieve maximum fault ride through capability of fixed speed wind turbines during symmetrical and asymmetrical grid faults

... Out of all the research mentioned above, in [8], [13], and [19], the authors used a STATCOM and distributed CPLs to achieve the maximum FRT capability of the FSWT. They have effective operation, especially in the ...

10

A Proposed Control Strategy to Improve the Low Voltage Ride through Capability of Pv System

A Proposed Control Strategy to Improve the Low Voltage Ride through Capability of Pv System

... rid through (LVRT) in distribution power systems, this paper proposes a control method to keep the dc-link voltage of PV system constant during low voltage rid through ...different fault ...

7

Show all 10000 documents...