• No results found

excitation coil

Analysis of high torque and power densities outer rotor PMFSM with DC excitation coil for in wheel direct drive

Analysis of high torque and power densities outer rotor PMFSM with DC excitation coil for in wheel direct drive

... field excitation coil (DC FEC), and armature coil located on the stator, the machine in which only a single piece of rotor iron is used becomes extremely ...hybrid excitation (HE) FSMs, and ...

8

Performances analysis of 6Slot 14Pole e core hybrid excitation flux switching machine for hybrid electric vehicle

Performances analysis of 6Slot 14Pole e core hybrid excitation flux switching machine for hybrid electric vehicle

... field excitation flux switching motor (FEFSM) and hybrid excitation flux switching motor ...field excitation coil (FEC), respectively as their main flux sources, while HEFSM combines both PM ...

8

FEA based design and parameter optimization study of 6 slot 5 pole PMFSM with field excitation for hybrid electric vehicle

FEA based design and parameter optimization study of 6 slot 5 pole PMFSM with field excitation for hybrid electric vehicle

... additional excitation has been proposed by the author as illustrated in ...additional excitation coils are also located at the stator side which gives extra advantage to the machine as a secondary flux ...

6

Performance comparison of 24S 10P and 24S 14P field excitation flux switching machine with single DC Coil polarity

Performance comparison of 24S 10P and 24S 14P field excitation flux switching machine with single DC Coil polarity

... field excitation (FE) FSMs, and hybrid excitation (HE) ...field excitation coil (FEC), respectively as their main flux sources, while HEFSMs combines both PM and FECs in the stator ...

6

Design investigation of three phase HEFSM with outer rotor configuration

Design investigation of three phase HEFSM with outer rotor configuration

... hybrid excitation (HE) FSMs, and field excitation (FE) ...DC excitation coil as their main flux sources, whereas for the HEFSMs, it combines both PM and DC excitation coil on the ...

6

Study on 10kV Quick Vacuum Circuit Breaker of Double Opening and Closing Coil

Study on 10kV Quick Vacuum Circuit Breaker of Double Opening and Closing Coil

... and excitation coil pulse discharge current is used in the mechanism, which makes the repulsion copper disk under the influence of the eddy current effect induced a large repulsion force, thus promoting the ...

5

Skin Effect in Eddy Current Testing with Bobbin Coil and Encircling Coil

Skin Effect in Eddy Current Testing with Bobbin Coil and Encircling Coil

... Eddy current testing (ECT) is widely used in industry for detecting defects in metallic components and ensuring structural safety [1–5]. The technology has many advantages such as single-side testing, being noncontact, ...

14

Performance comparison of 24slot 10pole and 12slot 8pole wound field three phase switched flux machine

Performance comparison of 24slot 10pole and 12slot 8pole wound field three phase switched flux machine

... field excitation SFM and hybrid excitation ...field excitation coil (FEC) in field excitation SFM while both permanent magnet and field excitation coil in hybrid ...

5

Design improvement of outer rotor hybrid excitation flux switching motor for in wheel drive electric vehicle

Design improvement of outer rotor hybrid excitation flux switching motor for in wheel drive electric vehicle

... field excitation flux switching machine (FEFSM), and hybrid excitation flux switching machine (HEFSM) as shown in Figure ...field excitation coil (FEC) as their main flux ...

38

Development of Microfabrication Process for Micro Inductive Sensors

Development of Microfabrication Process for Micro Inductive Sensors

... the excitation coil and the coupler coil for a newly designed micro inductive ...the excitation coil to reduce the driving ...the coil wire can be significantly reduced and more ...

138

Design refinement and performance analysis of 12slot 8pole wound field salient rotor switched flux machine for hybrid electric vehicles

Design refinement and performance analysis of 12slot 8pole wound field salient rotor switched flux machine for hybrid electric vehicles

... field excitation coil (FEC) slots and 8 rotor ...armature coil and FEC coil are located on the stator while the rotor part consists of only single piece ...

5

Design and optimization of hybrid excitation flux switching machine with FEC in radial direction

Design and optimization of hybrid excitation flux switching machine with FEC in radial direction

... In effort to increase the torque and power performance, design optimization approach is conducted to several design free parameter mark as D1 to D8 defined in rotor and stator part as shown in Fig. 2. The design ...

5

Endovascular Treatment of Experimental Aneurysms by Use of Biologically Modified Embolic Devices: Coil mediated Intraaneurysmal Delivery of Fibroblast Tissue Allografts

Endovascular Treatment of Experimental Aneurysms by Use of Biologically Modified Embolic Devices: Coil mediated Intraaneurysmal Delivery of Fibroblast Tissue Allografts

... Coil Embolization Procedure.—Right common femoral ar- tery access in the rabbits was achieved as described previously herein. A 4F catheter was advanced into the ascending aorta. Using coaxial technique, with a ...

11

Design optimization of a new
superconducting magnet system for a LAr
Neutrino Detector   A technical design report performed within the framework of a bachelor assignment as part of the
Advanced Technology bachelor programme at the ATLAS magnet group at C

Design optimization of a new superconducting magnet system for a LAr Neutrino Detector A technical design report performed within the framework of a bachelor assignment as part of the Advanced Technology bachelor programme at the ATLAS magnet group at CERN

... horizontal coil width (dcoil) had to take up values in the range of ...the coil reduces, resulting in lower peak ...horizontal coil width and still meet the magnetic field requirements, the single ...

69

Performance Investigation of Various Flux-Switching Machines for Hybrid Electric Vehicles: A Review

Performance Investigation of Various Flux-Switching Machines for Hybrid Electric Vehicles: A Review

... ABSTRACT: A demand for vehicles using electrical propulsion drives is getting higher and higher from the stand points of preventing global warming and saving fossil fuel recently. Hybrid electric vehicles (HEV) using ...

11

Simulink modelling and simulation for self excited doubly salient retarder system

Simulink modelling and simulation for self excited doubly salient retarder system

... the excitation current of the excitation winding of retarder power device), and also can determine the self-excitation retarder`s excitation ...retarder excitation current, rotor speed ...

6

Improving the Detection of Cholangiocarcinoma: In vitro MRI-Based Study Using Local Coils and T2 Mapping

<p>Improving the Detection of Cholangiocarcinoma: In vitro MRI-Based Study Using Local Coils and T2 Mapping</p>

... endoscope coil based on a thin- fi lm magneto-inductive waveguide and designed ultimately for internal ...torso coil was demonstrated using the endoscope coil, and improved tissue differentiation was ...

11

Hyperloop Transportation System using Electromagnetism

Hyperloop Transportation System using Electromagnetism

... consists of four unique types and that are rail, road, water, and air. These modes of transport tend to be either slow, expensive or a combination of both. Hyperloop is a new mode of transport that seeks to change this ...

5

Needleless electrospinning of uniform nanofibers using spiral coil spinnerets

Needleless electrospinning of uniform nanofibers using spiral coil spinnerets

... For coil electro- spinning, the minimum applied voltage for inducing the fiber generation was around 40 ...of coil electrospinning reduced with the increased collecting distance (Figure 6(b)), because a ...

10

RESIDUE APPROACH TO MATHEMATICAL ANALYSIS OF THE MOVING COIL GALVANOMETER

RESIDUE APPROACH TO MATHEMATICAL ANALYSIS OF THE MOVING COIL GALVANOMETER

...  Restoring couple ( Ʈ r ) arises due to twist in the suspension fibre and depends directly upon the deflection of the coil from mean position i.e. Ʈ s = −C ϴ(t), where 𝐶 is torsional rigidity of suspension fibre, ...

5

Show all 2427 documents...

Related subjects