• No results found

IEC-61850

Functional Testing of IEC 61850

Functional Testing of IEC 61850

... During the testing procedure, bugs and errors in device param- eters but sometimes also in the device’s firmware are detected and fixed. But every update of firmware version and as well as any change of device settings ...

6

Fault Location, Isolation, and Service Restoration (FLISR) Technique using IEC 61850 GOOSE

Fault Location, Isolation, and Service Restoration (FLISR) Technique using IEC 61850 GOOSE

... System is an important part of the electrical energy system to provide reliable, efficient and safe power to consumers. Implementation of performance rules in the high penetration and distribution system of distributed ...

8

Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2

Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2

... Abstract— Ethernet communication has been the back bone of high speed communication in digital substations from protection relaying, control and automation perspective. Major substation manufacturers have been constantly ...

5

Analysis of end-to-end delay characteristics for various packets in IEC 61850 substation communications system

Analysis of end-to-end delay characteristics for various packets in IEC 61850 substation communications system

... communication network architecture solutions are based on the IEC 61850 standard have been analyzed. The feasibility of the Ethernet substation communication networks are also been analyzed. (ii) Substation ...

5

Improving IEC 61850 interoperability and simplifying IED configuration through the standardisation of protection settings

Improving IEC 61850 interoperability and simplifying IED configuration through the standardisation of protection settings

... There are on-going activities to suggest extensions to the IEC 61850 data model for protection settings [9, 11]. The IEEE Power System Relaying Committee Working Group H5 (PSRC WG H5) published a report ...

8

DEMVE a Multi-Vendor Laboratory Environment for Research and Education Related to IEC 61850

DEMVE a Multi-Vendor Laboratory Environment for Research and Education Related to IEC 61850

... Research Issues Related to IEC 61850 Multi- Vendor Environment in Technobothnia. 21.3.2012 10[r] ...

12

Dynamic Testing of an IEC 61850 Based  110 kV Smart Substation Solution

Dynamic Testing of an IEC 61850 Based 110 kV Smart Substation Solution

... An IEC 61850 based aotomation design, transitioning the conventional substation into a smart substation, where existing current/voltage transformers remain in service, and smart Field Apparatus Interface ...

10

IEC 61850-based islanding detection and load shedding in substation automation systems

IEC 61850-based islanding detection and load shedding in substation automation systems

... an IEC 61850 GOOSE messaging-based fast LS scheme, where a fast load shedding controller (LSC) makes the final LS decisions in ...an IEC 61850-based load shedding (LS) ...

16

Monitoring and Controlling Services for Electrical Distribution Systems Based on the IEC 61850 Standard

Monitoring and Controlling Services for Electrical Distribution Systems Based on the IEC 61850 Standard

... In order to simplify the problem, only MAIN substation is considered, since the same analysis can be extended to the other substations. The purpose of the Laboratory is to build the schematic diagram derived from the ...

11

Standardization of power system protection settings using IEC 61850 for improved interoperability

Standardization of power system protection settings using IEC 61850 for improved interoperability

... the IEC 61850 Java objects are created, which not only allows the settings to be represented by IEC 61850 data models but also allows the settings in the IEC 61850 data model to ...

5

Architecture for automatically generating an efficient IEC 61850-based communications platform for rapid-prototyping of protection schemes

Architecture for automatically generating an efficient IEC 61850-based communications platform for rapid-prototyping of protection schemes

... The platform is designed to be lightweight; only GSE and SV messages – crucial for protection – are implemented. The communications infrastructure will ensure that the required GSE and SV data are available to the ...

6

Analysis of end-to-end delay characteristics among various packet sizes in modern substation communication systems based on IEC 61850

Analysis of end-to-end delay characteristics among various packet sizes in modern substation communication systems based on IEC 61850

... The main objective of this paper is to model, simulate and compare the end-to-end delay characteristics among different data packet sizes as well as different types of network topologies using IEC 61850. ...

5

Adapting LTE M 2 M Protocol Standard to Fulfil Latency Requirements for IEC 61850 GOOSE Messages

Adapting LTE M 2 M Protocol Standard to Fulfil Latency Requirements for IEC 61850 GOOSE Messages

... IEC 61850 GOOSE message over WAN presented in [2], Because of the new requirements that tends to transfer GOOSE messages within the WAN, to enhance the communication between substations, new tech- niques ...

7

A Novel IEC 61850 Based Protection Scheme to Maintain the Generator
Synchronous Operation During Power System Disturbances

A Novel IEC 61850 Based Protection Scheme to Maintain the Generator Synchronous Operation During Power System Disturbances

... between IEC 61850 based IEDs either for protection or for ...utilize IEC 61850-8-1 communication service for event and status delivery within real-time protection and control ...

14

Translating proprietary protection setting data into standardized IEC 61850 format for protection setting validation

Translating proprietary protection setting data into standardized IEC 61850 format for protection setting validation

... Relay Object Class is the Java representation of the relay and is initialised using the data extracted from the data acquisition process. The IEC 61850 Translator Class contains the mappings between the ...

6

A Study on Unified Testing Method for IEC 61850 Based Server with Focus on Setting Group Function

A Study on Unified Testing Method for IEC 61850 Based Server with Focus on Setting Group Function

... operation. IEC 61850 communication standard has been defined for information exchange between heterogeneous digital devices in such ...the IEC 61850 Setting Group function, and propose a ...

13

An open platform for rapid-prototyping protection and control schemes with IEC 61850

An open platform for rapid-prototyping protection and control schemes with IEC 61850

... particularly IEC 61850, in the course of the research and development of novel schemes can be ...the IEC 61850 standard, by providing a framework for validating SCD files and by automating ...

8

An Investigation into the testing and commissioning requirements of IEC 61850 Station Bus Substations

An Investigation into the testing and commissioning requirements of IEC 61850 Station Bus Substations

... 57 of the subscribing IEDs. This task could also potentially create a mismatch with the virtual input mapping within the system configuration tool and the mapping of the virtual inputs within the IED’s internal address ...

119

Demonstration and analysis of IP/MPLS communications for delivering power system protection solutions using IEEE C37.94, IEC 61850 Sampled Values, and IEC 61850 GOOSE protocols

Demonstration and analysis of IP/MPLS communications for delivering power system protection solutions using IEEE C37.94, IEC 61850 Sampled Values, and IEC 61850 GOOSE protocols

... the IEC 61850 standard offers many compelling advantages for these schemes, including high- speed Ethernet communications, a standardised data model, a standardised configuration methodology, and vendor ...

9

SysGRID: IEC 61850 and IEC 61499 Standard Based Engineering Tool for Smart Grid Automation Design

SysGRID: IEC 61850 and IEC 61499 Standard Based Engineering Tool for Smart Grid Automation Design

... The logical nodes function blocks that are automatically generated are iLN [6], which are composite function block made up of a database FB and an intelligence FB as shown in Figure 10. The database FB contains the data ...

8

Show all 177 documents...