• No results found

Kirschner wire

Kirschner Wire Fixation of Neglected Lateral Condylar Fracture of the Humerus in Children

Kirschner Wire Fixation of Neglected Lateral Condylar Fracture of the Humerus in Children

... The current study demonstrates significant biomechanical advantages of screw fixation as compared with Kirschner wire fixation of lateral condyle frac- tures using a synthetic bone model. Displaced ...

20

Comparative analysis of functional outcome of multiple metatarsal fractures treated with plate osteosynthesis and kirschner wire fixation

Comparative analysis of functional outcome of multiple metatarsal fractures treated with plate osteosynthesis and kirschner wire fixation

... I, Dr.C.CHANDRU, solemnly declare that the dissertation titled“COMPARATIVE ANALYSIS OF FUNCTIONAL OUTCOME OF MULTIPLE METATARSAL FRACTURES TREATED WITH PLATE OSTEOSYNTHESIS AND KIRSCHNER WIRE FIXATION”has ...

99

Comparative Study of Functional Outcome in Colles’ Fracture Treated Conservatively by Closed Reduction and Cast and Closed Reduction, Kirschner Wire and Cast

Comparative Study of Functional Outcome in Colles’ Fracture Treated Conservatively by Closed Reduction and Cast and Closed Reduction, Kirschner Wire and Cast

... Aim To study comparative evaluation of functional outcome in Colles’ fracture treated conservatively by closed reduction and cast and closed reduction, Kirschner wire and cast. Materials and Methods Thirty ...

5

RETRACTED ARTICLE: Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures in Chinese Han population: a meta-analysis

RETRACTED ARTICLE: Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures in Chinese Han population: a meta-analysis

... CRIF has been widely used to treat the majority of unstable closed simple hand fractures [2] and has been a mainstay of treatment for most phalangeal fractures [3] since the percutaneous screws and Kirschner ...

7

Original Article Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis

Original Article Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis

... ficiency of surgeons and different types of dis- tal radius fractures. Since the sample size of some RCTs was small, patient age was con- sidered as another source of heterogeneity. Previous study indicated that in ...

10

Biomechanical effects of osteoplasty with or without Kirschner wire augmentation on long bone diaphyses undergoing bending stress: implications for percutaneous imaging-guided consolidation in cancer patients

Biomechanical effects of osteoplasty with or without Kirschner wire augmentation on long bone diaphyses undergoing bending stress: implications for percutaneous imaging-guided consolidation in cancer patients

... The purpose of this study was to evaluate the bio- mechanical properties of osteoplasty alone and in com- bination with Kirschner wires (K-wires) in a cadaveric human diaphyseal model su[r] ...

9

A novel method for internal fixation of basal fifth metatarsal fracture in athletes: a cadaveric study of the F.E.R.I. technique (Fifth metatarsal, Extra-portal, Rigid, Innovative)

A novel method for internal fixation of basal fifth metatarsal fracture in athletes: a cadaveric study of the F.E.R.I. technique (Fifth metatarsal, Extra-portal, Rigid, Innovative)

... of Kirschner wire fixation of fifth metatarsal base fractures (in combination with a tension band wiring technique) seems to be hardware intolerance and several studies in athletes also report failure after ...

7

FUNCTIONAL RESULTS OF COLLES' FRACTURE MANAGED BY PERCUTANEOUS CROSSED KIRSCHNER WIRES.Niaz Hussain*, Imran Javed, Muhammad Ali DOWNLOAD/VIEW

FUNCTIONAL RESULTS OF COLLES' FRACTURE MANAGED BY PERCUTANEOUS CROSSED KIRSCHNER WIRES.Niaz Hussain*, Imran Javed, Muhammad Ali DOWNLOAD/VIEW

... percutaneous Kirschner wire fixation combined with plaster cast versus conventional plaster cast immobilization in the treatment of Colles’ fracture – a prospective randomized comparative ...Krischner ...

5

Original Article A modified internal suture technique for treatment of the tendinous mallet finger

Original Article A modified internal suture technique for treatment of the tendinous mallet finger

... transarticular Kirschner wire fixation technique provided an accurate anatomical fixa- tion and acceptable treatment modality for the treatment of tendinous mallet finger ...

6

Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children

Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children

... percutaneous Kirschner wire ...and Kirschner wire fixation for treatment of neglected, displaced supracondylar and distal humeral fractures in ...

12

The application of the Risdon approach for mandibular condyle fractures

The application of the Risdon approach for mandibular condyle fractures

... For cases where open reduction is necessary, the sur- geon can make a choice between intraoral and extraoral approaches. Although intraoral reduction is generally accepted for symphyseal and parasymphyseal fractures, ...

7

Foot Deformities in Hajdu-Cheney Syndrome: A Rare Case Report and Review of the Literature

Foot Deformities in Hajdu-Cheney Syndrome: A Rare Case Report and Review of the Literature

... Case Report: We report a case of a 50-year-old female with bilateral foot deformities as a manifestation of the rare genetic disorder HCS. Surgical management of the left foot consisted of Morton’s neuroma excision and ...

5

Original Article Solitary juvenile xanthogranuloma with tibial involvement: a case report

Original Article Solitary juvenile xanthogranuloma with tibial involvement: a case report

... fibula, lesion curettage and bone grafting (right fibula and artificial bone) on the left tibia, Kirschner wire internal fixation, plaster external fixation on the both lower limbs (Figure 4). A yel- lowish ...

7

In Situ Fabrication of Ribbed Wire Electrodes for Wire Electrochemical Micromachining

In Situ Fabrication of Ribbed Wire Electrodes for Wire Electrochemical Micromachining

... ribbed wire electrode with large L/D ratio, which makes full use of the existing equipment and avoids the machining errors generated by holding the parts by fixture ...ribbed wire electrode was ...

10

Percutaneous elastic intramedullary nailing of metacarpal fractures: Surgical technique and clinical results study

Percutaneous elastic intramedullary nailing of metacarpal fractures: Surgical technique and clinical results study

... drill wire by hand. A T- piece mounted K-wire is then inserted blunt end first in an ante grade manner into the medullary canal after fracture ...the wire in the form of a hockey club can be used to ...

5

WIRE STEERING

WIRE STEERING

... The SBW system I build can be improved a lot, but the main problem seems to be with thechoice of controllers and motors. For a future project, given better equipment, this system couldbe implemented in a small model car ...

11

Transient Analysis of a Rectangular Cavity Containing an Interior Scatterer Using TD-EFIE with Weighted Laguerre Polynomials as Temporal Basis Functions

Transient Analysis of a Rectangular Cavity Containing an Interior Scatterer Using TD-EFIE with Weighted Laguerre Polynomials as Temporal Basis Functions

... the wire are perfectly conducting and very thin; 2) the wire is oriented parallel to the slot; and 3) The wire ends may not be in electrical contact with the cavity ...

14

Ligation of the wire: clinical update

Ligation of the wire: clinical update

... sectional wire with a right angle bend in the initial stages of bracket engagement for uprighting, leveling, and rotating involves the risk of having the wire rotate on itself in the ...ligature wire ...

8

Gaps and Opportunities in Various Aspects and Treatment/Management of Distal Radius Fractures

Gaps and Opportunities in Various Aspects and Treatment/Management of Distal Radius Fractures

... The true economic burden of DRFs is unclear because of three reasons. First, only few studies have been published on this aspect [73,78-83]. Thus, 1) in 1997, it was estimated that the mean cost for treating a patient ...

10

FRICTIONAL EFFECT IN PACEMAKER LEAD CABLE DUE TO COUPLED CONTACT MODE

FRICTIONAL EFFECT IN PACEMAKER LEAD CABLE DUE TO COUPLED CONTACT MODE

... A Pacemaker is a device which conducts electrical impulses from pulse generator to heart muscle when the heart beat is abnormal. This electrical impulse are conducted to heart muscle by means of lead cables which numbers ...

5

Show all 1703 documents...

Related subjects