• No results found

Knee prosthesis

Adaptive Probabilistic Approach for Selecting Tumour Knee Prosthesis

Adaptive Probabilistic Approach for Selecting Tumour Knee Prosthesis

... Tumour knee prostheses reconstruct bone gaps, left after resecting the tumour affected tissues, in limb salvage surgeries of bone cancer ...tumour knee prosthesis components, driven by geometric ...

22

Dynamic Stresses and Deformations Investigation of the Below Knee Prosthesis using CT-Scan Modeling

Dynamic Stresses and Deformations Investigation of the Below Knee Prosthesis using CT-Scan Modeling

... below knee prosthesis and socket part investigated from many researchers at previous ...below knee, in addition to, investigated the creep and fatigue characterizations for materials used to ...

9

Design quasi passive exoskeleton for below 
		knee prosthesis

Design quasi passive exoskeleton for below knee prosthesis

... In ankle angle, plantar flexion takes place when the tiptoe falls down, while dorsal flexion happens as the tiptoe is raised up. People who suffer from amputation may be get of balanced from the center of gravity [1, 2 ...

8

Value of digital telethermography for the diagnosis of septic knee prosthesis: a prospective cohort study

Value of digital telethermography for the diagnosis of septic knee prosthesis: a prospective cohort study

... – The value of telethermography has only been investigated at a minimum of one year after surgery. Previous analysis showed a reproducible pattern in the course of temperature at the surgical site, with a peak of ...

7

THE IMPACT OF UNDER KNEE PROSTHESIS ON VARIOUS DIMENSIONS OF LIFE QUALITY OF DISABLED INDIVIDUALS REFERRING TO REHABILITATION CENTER OF SHIRAZ RED CRESCENT IN 2017

THE IMPACT OF UNDER KNEE PROSTHESIS ON VARIOUS DIMENSIONS OF LIFE QUALITY OF DISABLED INDIVIDUALS REFERRING TO REHABILITATION CENTER OF SHIRAZ RED CRESCENT IN 2017

... under knee prosthesis impacts subscale of TAPES life quality questionnaire which is consistent with the results of a previous study 19 ...that prosthesis plays a considerable role on people mobility ...

6

Finite Element Analysis of A Retrieved Custom-Made Knee Prosthesis

Finite Element Analysis of A Retrieved Custom-Made Knee Prosthesis

... Custom-made knee prostheses have been widely used to reconstruct the function of the lower limb in bone tumor ...tumor knee prosthesis was retrieved on account of prosthesis loosening ...the ...

16

The simultaneous diagnosis of malalignment and liner wear in problematic primary total knee prosthesis with low field MRI

The simultaneous diagnosis of malalignment and liner wear in problematic primary total knee prosthesis with low field MRI

... The results from the malalignment measurements provide varying results with respect to the com- parison of pathological total knee prosthesis and healthy controls. When comparing the results with the ...

85

A New Knee Prosthesis Design Based on Human Lower Limb Cinematic Analysis

A New Knee Prosthesis Design Based on Human Lower Limb Cinematic Analysis

... the prosthesis resistance structure, which enables some axial adjustments with a view to establishing the prosthesis ...new knee prosthesis ...this prosthesis in accordance with an ...

6

Modeling and Finite Element Analysis of Knee Prosthesis with and without Implant

Modeling and Finite Element Analysis of Knee Prosthesis with and without Implant

... forces. Knee joint is the complex structure of the human body acquires the critical loads in various moving ...of knee prosthesis and evaluate the results in the form of stresses by applying the ...

11

A Comparison of Patient Outcomes Following Prosthetic Knee Replacement Using a Variety of Knee Prosthesis: A Ten Year Study

A Comparison of Patient Outcomes Following Prosthetic Knee Replacement Using a Variety of Knee Prosthesis: A Ten Year Study

... of knee prosthesis in use in the United ...of prosthesis options, in combination with the variety in patient factors, makes the choice of an optimum prosthesis for a replacement a not ...

9

Long-term results of a total knee prosthesis utilising an all polyethylene tibial component

Long-term results of a total knee prosthesis utilising an all polyethylene tibial component

... prosthesis interface of the tibial component using the Knee Society Total Knee Arthroplasty.. radiographic evaluation system.[r] ...

12

Material Characterization and Stress Analysis of a Through Knee Prosthesis Sockets

Material Characterization and Stress Analysis of a Through Knee Prosthesis Sockets

... the vertical component. Due to the fact that the effective, conical angle of the prosthetic socket shell, is very little, the chief component, of the normal force acts in horizontal, direction and presses the skin ...

8

The effect of a biphasic injectable bone substitute on the interface strength in a rabbit knee prosthesis model

The effect of a biphasic injectable bone substitute on the interface strength in a rabbit knee prosthesis model

... A rabbit tibia prosthesis has been designed for this model [10]. It is manufactured in one size and identical for left and right knees (manufactured by the Dept. of Medical Technique in Lund University Hospital, ...

7

Patellofemoral contact patterns before and after total knee arthroplasty: an in vitro measurement

Patellofemoral contact patterns before and after total knee arthroplasty: an in vitro measurement

... different knee positions be- tween 45°and 120° ...different knee positions with a constant quadriceps load of 280 N and only with a pressure sensitive ...of knee flexion without subdividing the ...

13

PubMedCentral-PMC5670174.pdf

PubMedCentral-PMC5670174.pdf

... It is important to understand our results represent the behavior of our small sample size, and may not represent the behavior of the entire amputee population. Rather, our pilot study explores a novel type of ...

12

Design of An Expert System to Automatically Tune the Impedance Control for Powered Knee Prostheses.

Design of An Expert System to Automatically Tune the Impedance Control for Powered Knee Prostheses.

... the knee joint angular ...powered prosthesis was tethered and controlled by a desktop ...powered knee prosthesis was based on finite-state impedance ...GRF, knee joint angle, and ...

77

Amputee perception of prosthetic ankle stiffness during locomotion

Amputee perception of prosthetic ankle stiffness during locomotion

... below-knee prosthesis users to changes in pros- thetic ankle stiffness during walking by measuring the repeatability of user-selected preferred stiffness and dif- ference threshold for ...

10

Preoperative Clinical Correctability and Prediction of the Prosthesis Type in Total Knee Arthroplasty for ‌Severe Osteoarthritic Varus Deformity

Preoperative Clinical Correctability and Prediction of the Prosthesis Type in Total Knee Arthroplasty for ‌Severe Osteoarthritic Varus Deformity

... CCK prosthesis was mainly based on the preoperative level of ligamentous stability, intraop- erative evaluation of competency of the collateral liga- ments, and on-table evaluation of coronal plane stability ...

6

Original Article The influence of knee position on blood loss and range of motion following total knee arthroplasty: a meta-analysis

Original Article The influence of knee position on blood loss and range of motion following total knee arthroplasty: a meta-analysis

... To assemble all of the relevant published stud- ies, PRISMA compliant searches of MEDLINE, EMBASE, Science Direct, OVID, the Cochrane CENTRAL database and Google scholar were performed for all peer-reviewed studies pub- ...

8

Debridement, antibiotics, and implant retention for periprosthetic knee infections: a pooling analysis of 1266 cases

Debridement, antibiotics, and implant retention for periprosthetic knee infections: a pooling analysis of 1266 cases

... The present analysis conferred a low success pro- portion of 57.11% for PKI treated with DAIR, which is similar to what was reported in previous meta- analyses. Romano et al. [48] reported a low success rate of 45.9% ...

8

Show all 4328 documents...

Related subjects