• No results found

liquid–liquid interface

Energy dispersive-EXAFS of Pd nucleation at a liquid/liquid interface

Energy dispersive-EXAFS of Pd nucleation at a liquid/liquid interface

... galvanic liquid/liquid cell revealed a regime of spatial instability compatible with the density fluctuations expected when growth and dissolution of sub-critical Pd nuclei take place in a supersaturated ...

5

In situ XAFS Study of Palladium Electrodeposition at the Liquid/Liquid Interface

In situ XAFS Study of Palladium Electrodeposition at the Liquid/Liquid Interface

... control appears to eliminate the formation of long-lived pre-nucleation clusters involved in the oscillatory growth observed when the potential is not constrained. Applied potentials above or below (0.30 V or 0.40 V) the ...

39

Filament and Droplets Formed Behind a Solid Sphere Rising Across a Liquid Liquid Interface

Filament and Droplets Formed Behind a Solid Sphere Rising Across a Liquid Liquid Interface

... an interface between molten metal and ...a liquid drop resting at a liquid-liquid interface, 3,4) a bubble rising through the ...

7

On The Rupture of a Liquid Film Formed on a Droplet Crossing a Horizontal Liquid Liquid Interface

On The Rupture of a Liquid Film Formed on a Droplet Crossing a Horizontal Liquid Liquid Interface

... The shape of a droplet exposed to gravity and interacting with a liquid-liquid interface is approximated by ellipsoid generated by revolution of an ellipse around its minor (vertical) axis. The ...

6

Ion Transfer Study on a New Designed Nanocomposite Carbon Paste Electrode

Ion Transfer Study on a New Designed Nanocomposite Carbon Paste Electrode

... the liquidliquid interface dominates only when more hydrophobic redox probes such as decamethylferrocene (DMFc) and t-butylferrocene (tBuFc) were used, because the stability of voltammograms ...

10

Investigation of the Consecutive Electron Transfer of Metalloporphyrin Species on the Simulative Cell Membrane by Thin Layer Cyclic Voltammetry

Investigation of the Consecutive Electron Transfer of Metalloporphyrin Species on the Simulative Cell Membrane by Thin Layer Cyclic Voltammetry

... the liquid/liquid interface of biological ...the liquid/liquid interface in biomembranes has been suggested as a simplified model for understanding the mechanism of electron ...

11

Investigation of Microchannel Based Fuel Cell

Investigation of Microchannel Based Fuel Cell

... using liquid fuels which have higher energy densities as opposed to the gaseous fuels used in typical PEMFCs ...the liquid-liquid interface in the middle of the channel where the solution ...

6

Electrochemical control of organic reactions involving phase transfer

Electrochemical control of organic reactions involving phase transfer

... a liquid/liquid interface could involve the use o f electrodes to carry out the two-phase synthesis on a normal reaction ...the interface using the two ...the interface between ...the ...

144

Real Space Imaging of Nanoparticle Assembly at Liquid-Liquid Interfaces with Nanoscale Resolution.

Real Space Imaging of Nanoparticle Assembly at Liquid-Liquid Interfaces with Nanoscale Resolution.

... the liquid/liquid interface case, such a rupture event occurs however at large indentation depths of several hundreds of nanometers, since the whole interface is deformed under the pressure of ...

17

Simultaneous Tracking of Pseudomonas aeruginosa Motility in Liquid and at the Solid-Liquid Interface Reveals Differential Roles for the Flagellar Stators

Simultaneous Tracking of Pseudomonas aeruginosa Motility in Liquid and at the Solid-Liquid Interface Reveals Differential Roles for the Flagellar Stators

... To gain novel insights into the differences in cell behavior within the bulk and at the surface, it is necessary to image both environments concurrently. To achieve this, we developed a novel multimode 2/3D microscope ...

18

The behaviour of ions in the presence of the liquid vapour interface in helium

The behaviour of ions in the presence of the liquid vapour interface in helium

... little space charge will he huilt up helow the free surface. If the impedance to earth is greater, for example hy the substrate heing so rough that the film current is very small, then surface charge will establish ...

193

Communication: long range corrections in liquid vapor interface simulations

Communication: long range corrections in liquid vapor interface simulations

... +1.6 % with recent MD results obtained by Werth, Lishchuk, Horsch, and Hasse 10 which we believe to be presently the most reliable simulation results for the LJ liquid-vapor interface. It should still be ...

14

Disorder trapping by rapidly moving phase interface in an undercooled liquid

Disorder trapping by rapidly moving phase interface in an undercooled liquid

... phase interface propagation is sluggish at small ...the liquid to the phase interface needs short-range atomic diffusion, since atoms have to move to the proper lattice site in the super- lattice ...

10

Evaluation of secondhand smoke effects on CFTR function in vivo

Evaluation of secondhand smoke effects on CFTR function in vivo

... Use of Primary human bronchial epithelial (HBE) cells from non-CF CFTR+/+ subjects was approved by the In- stitutional Review Boards at the University of Alabama Birmingham. HBE cells were generated from lung ex- plants ...

14

Expansion Characteristics of a Plasma Jet in the Stepped Wall Chamber Filled with Water

Expansion Characteristics of a Plasma Jet in the Stepped Wall Chamber Filled with Water

... the liquid chamber was in- troduced as a potential mean of controlling the combustion of bulk-loaded liq- uid propellant [7], and this approach was further developed and tested by expe- rimental and numerical ...

9

Liquid: Designing a Universal Sensor Interface for Ubiquitous Computing

Liquid: Designing a Universal Sensor Interface for Ubiquitous Computing

... Once all the necessary sensors are selected, the toolkit loads the respective device drivers and waits on the designated port for a communiqué from the users application which signals when it is ready to receive command ...

9

Moses Effect (Deformation of Diamagnetic Liquid/Vapor Interface

Moses Effect (Deformation of Diamagnetic Liquid/Vapor Interface

... diamagnetic liquid/vapor interface by magnetic field, called also as the “Moses Effect” [16-17, ...creates liquid bulges, and it is called the “inverse Moses Effect” [16, ...diamagnetic ...

17

Communication: long range corrections in liquid vapor interface simulations

Communication: long range corrections in liquid vapor interface simulations

... Long range corrections (lrc) for the potential energy and for the force in planar liquid-vapor inter- face simulations are considered for spherically symmetric interactions. First, it is stated that for the ...

6

Spectroscopic considerations on molecular adsorption at the solid/liquid interface

Spectroscopic considerations on molecular adsorption at the solid/liquid interface

... the three main features. These values mean that ~ 45% of the simulation is derived from Au(110)/ethanol + DCNT after 15 minutes adsorption while ~ 55% originates from Au(110)/ethanol + DCNT at saturation coverage. Figure ...

229

Show all 10000 documents...

Related subjects