• No results found

Multiple sample analysis with electrokinetic injection

Novel Fusion Electrokinetic Technology with Gas Re-Injection (GREK) for Soil Remediation and Stabilization

Novel Fusion Electrokinetic Technology with Gas Re-Injection (GREK) for Soil Remediation and Stabilization

... each sample calculated were ...the injection type treatment ...type electrokinetic remediation treatment showed more efficient performance compared to the case of non-injection type treatment ...

5

Portable monitors for flow injection analysis with potentiometric multiple ion sensors

Portable monitors for flow injection analysis with potentiometric multiple ion sensors

... Individual photo-cured bisphenol A epoxydiacrylate membrane based CWEs for ammonium, calcium, hydrogen, nitrate and potassium were developed and evaluated using silver wire electrodes [r] ...

175

Design And Analysis Of Plastic Injection Mould Using Multiple Cavity Mould

Design And Analysis Of Plastic Injection Mould Using Multiple Cavity Mould

... mould. Multiple Cavity Moulding may cause the material used to be melted partially that disrupts the flow into the runner which cause the runner to be stuck with ...

24

Principles of Micellar Electrokinetic Capillary Chromatography Applied in Pharmaceutical Analysis

Principles of Micellar Electrokinetic Capillary Chromatography Applied in Pharmaceutical Analysis

... MEKC is a branch of CE, which has become during the years one of the most popular techniques in CE due to its high resolving power and capability of separating both ionic and neutral analytes. MEKC is the most flexible ...

8

PREFAIL: A Programmable Tool for Multiple-Failure Injection

PREFAIL: A Programmable Tool for Multiple-Failure Injection

... der failures”. That is, we note that many program analy- ses (related to data races, deadlocks, security, etc.) are of- ten done when the target system faces no failure. However, we did find data races and deadlocks ...

17

Methods to adjust for multiple comparisons in the analysis and sample size calculation of randomised controlled trials with multiple primary outcomes

Methods to adjust for multiple comparisons in the analysis and sample size calculation of randomised controlled trials with multiple primary outcomes

... The sample size can vary greatly depending on if the marginal power or overall disjunctive power is used highlighting the importance of calculating the sample size based on the trial ...the sample ...

13

Methods to adjust for multiple comparisons in the analysis and sample size calculation of randomised controlled trials with multiple primary outcomes

Methods to adjust for multiple comparisons in the analysis and sample size calculation of randomised controlled trials with multiple primary outcomes

... increases for all approaches. We do not consider the power obtained when using the D/AP approach due to its poor performance in controlling the FWER. When there is no missing data, the Stepdown minP and Hom- mel ...

13

Visualized Classification of Multiple Sample Types

Visualized Classification of Multiple Sample Types

... The goal of the knowledge discovery and data mining is to extract the useful knowledge from the given data. Visu- alization enables us to find structures, features, patterns, and relationships in a dataset by presenting ...

8

Flow Injection Analysis

Flow Injection Analysis

... A) Sample injection is designed to meter an exact volume of analyte solution into a flowing stream of ...the sample zone (red) moves downstream, the dispersion process mixes sample with ...

6

Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries

Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries

... indirect analysis method has been successfully applied for the specia- tion of arsenic compounds by using an SMIL-coated ...hanced sample injection on-line precon- centration technique can be applied ...

5

Determination of artemether and lumefantrine in anti malarial fixed dose combination tablets by microemulsion electrokinetic chromatography with short end injection procedure

Determination of artemether and lumefantrine in anti malarial fixed dose combination tablets by microemulsion electrokinetic chromatography with short end injection procedure

... Satisfactory results were obtained for method validation with respect to selectivity, linearity of the response func- tion, recovery experiments and precision. In comparison with the HPLC methods reported in the ...

8

Sample-level enrichment analysis unravels shared stress phenotypes among multiple cancer types

Sample-level enrichment analysis unravels shared stress phenotypes among multiple cancer types

... alternative approach for the analysis of tumor genomics data to detect clinically relevant patient subgroups. Instead of finding genes differentially expressed between two groups, we identify differentially ...

15

Semiquantitative RT-PCR analysis to assess the expression levels of multiple transcripts from the same sample

Semiquantitative RT-PCR analysis to assess the expression levels of multiple transcripts from the same sample

... per sample and moreover, requires intensive initial work when different RNAs have to be analyzed and hence different mimic competitors need to be ...same sample, we preferred to work on the same cDNA ...

7

The Effect of Silver Nanoparticles on Selenium Speciation Analysis in Water Sample by Flow Injection-Hydride Generation Atomic Absorption Spectrometry

The Effect of Silver Nanoparticles on Selenium Speciation Analysis in Water Sample by Flow Injection-Hydride Generation Atomic Absorption Spectrometry

... Effect of analytical matrix on Se determination Although the suitable reducing agents can be applied for Se analysis in real samples, the matrix effect at ultra-trace level of selenium species still appears from ...

11

Analysis of dioxin and furan related compounds and organophosphorous pesticdes using micellar electrokinetic chromatography

Analysis of dioxin and furan related compounds and organophosphorous pesticdes using micellar electrokinetic chromatography

... offering sample enrichment. SPDE is also able to do sample clean-up by removing interference in the matrix that would interfere with the ...real sample analysis of spiked deionised water and ...

33

Electrokinetic analysis of PES/PVP membranes aged by sodium hypochlorite solutions at different pH

Electrokinetic analysis of PES/PVP membranes aged by sodium hypochlorite solutions at different pH

... The most significant change, in terms of both permeability and PEG rejection, was undergone by the membrane aged at pH 8.0. A slight increase in permeability accompanied with a significant decrease in PEG rejections were ...

35

cFinder: definition and quantification of multiple haplotypes in a mixed sample

cFinder: definition and quantification of multiple haplotypes in a mixed sample

... Overall, all clones and their frequencies are designated with a minimum of user interaction. The tool can be used for data analysis for research as published in [8]. Both alignment types (AVA and CLC) showed a ...

6

Effect Of Compression Ratio And Injection Pressure On The Performance And Emission Of C.I. Engine With Multiple Injection Techniques -A Review Study

Effect Of Compression Ratio And Injection Pressure On The Performance And Emission Of C.I. Engine With Multiple Injection Techniques -A Review Study

... experimental analysis was conducted for the better under- standing of combustion stabil- ity and reduction of exhaust emission in low compression ratio (CR) ...

7

Reproducing system-level bulk current injection test in direct power injection setup for multiple-port DUTs

Reproducing system-level bulk current injection test in direct power injection setup for multiple-port DUTs

... The system level test setups usually contain of one or more electronic control units (ECU, here called EUT), connected to each other or to the support circuitry with a cable har- ness. A sample system discussed in ...

6

Flow injection: A new approach in analysis

Flow injection: A new approach in analysis

... flow injection analysis (FIA), which is computer compatible and allows automated handling of sample and reagent solutions with a strict control of reaction ...flow injection analysis ...

8

Show all 10000 documents...

Related subjects