• No results found

nuclear power-plant safety model

Model of an Accident-Induced Fire around a Nuclear Power Plant

Model of an Accident-Induced Fire around a Nuclear Power Plant

... the safety of the surrounding ...Dynamic) model using the LES (Large Eddie Simulation) is used to calculate the fire’s development and the spread of the combustion products in the ...hazardous plant, ...

12

Study on numerical method for estimation of surface fault displacement

Study on numerical method for estimation of surface fault displacement

... A reliable estimation of surface fault displacements is a crucial issue to the safety of nuclear power plant facilities. It is necessary to develop a numerical method for the estimation. In ...

10

A proposal for a unified model on Nuclear Power Plant Life Management including Maintenance Optimisation

A proposal for a unified model on Nuclear Power Plant Life Management including Maintenance Optimisation

... The European Commission, especially in the framework of the EURATOM programme, identified specific R&D priorities to be mainly addressed by “direct actions” managed by the Joint Research Centre (JRC) in the field of ...

8

Does nuclear power plants affect house prices? : a hedonic price model of Forsmark nuclear power plant

Does nuclear power plants affect house prices? : a hedonic price model of Forsmark nuclear power plant

... Nuclear power plants existences have been well debated since the 70s (Swedish radiation safety authority, ...to nuclear power plants have been part of many studies around the ...of ...

40

The   Reevaluation of Seismic Safety of Existing Nuclear Power Plant (K598)

The Reevaluation of Seismic Safety of Existing Nuclear Power Plant (K598)

... The details of the model are determined based on the so-called “the amendment recipe” in ref. [2] also proposed by Irikura recently to have conservative input ground motion. The time histories obtained are shown ...

8

Safety   Analysis of Ulchin Nuclear Power Plant against Tsunami

Safety Analysis of Ulchin Nuclear Power Plant against Tsunami

... The numerical model simulating the run-up process of tsunami is used to calculate the maximum run-up heights at Ulchin nuclear power plant located at the Eastern coast[r] ...

7

Idealization of aircraft engine model in structural safety assessment of nuclear power plant against large civil aircraft crash

Idealization of aircraft engine model in structural safety assessment of nuclear power plant against large civil aircraft crash

... element model by solving explicit nonlinear ...FE model of Boeing 767 aircraft and its popular engine PW4000-94, shown in figure 1, manufactured by Pratt & Whitney ...spent nuclear fuel storage ...

7

Passive Safety in the Engineering of Nuclear Power Plant Buildings

Passive Safety in the Engineering of Nuclear Power Plant Buildings

... Horizontal loads due to accidental impacts such as airplane crash, explosion pressure waves and earthquakes should be transmitted by clearly defined horizontal and vertical stiffening members. This principle is ...

9

Safety Analysis against Tsunami Attacks at Ulchin Nuclear Power Plant Site

Safety Analysis against Tsunami Attacks at Ulchin Nuclear Power Plant Site

... numerical model based on the shallow-water theory is employed to analyze the safety of the Ulchin Nuclear Power Plant site against three historical and eleven virtual tsunami ...

6

Efficient Reliability Modelling & Analysis of Complex Systems with Application to Nuclear Power Plant Safety

Efficient Reliability Modelling & Analysis of Complex Systems with Application to Nuclear Power Plant Safety

... However, most Monte Carlo simulation algorithms [61, 81, 161] require state enu- meration and prior knowledge of the system's structure function, path sets, or cut sets when solicited for multi-state system reliability ...

222

Probabilistic   Safety Assessment of the Steam Generator Cover (M449)

Probabilistic Safety Assessment of the Steam Generator Cover (M449)

... If statistical data are available for all the variables, the statistical characteristics can be estimated, and a theoretical model of probability distribution function can be assigned by well-known procedures of ...

10

Risk-informed SSC Classification at the Design Stage via  Reliability Allocation Approach

Risk-informed SSC Classification at the Design Stage via Reliability Allocation Approach

... With the developed model, an optimization is performed to minimize the number of SSCs which belong to the SRSS group. The fitness of an the individual is measured by using an objective function. We defined the ...

8

Case Study of Reactor Containment Building Construction in Nuclear Power Plant

Case Study of Reactor Containment Building Construction in Nuclear Power Plant

... Wolseong Nuclear Power Plant 1, as indicated in Table ...the nuclear power plant construction, Korea entered an agreement on the first step operation of and the support of ...

11

Electricity From Nuclear Power: Is It A Solution To Greenhouse Gas Emissions In India

Electricity From Nuclear Power: Is It A Solution To Greenhouse Gas Emissions In India

... the Power plant. [3]Being a better source of power generation, installed capacity of Nuclear based power plant must be increased because coal based power plant can ...

6

Principles governing the Seismic Design of Nuclear Power Plants with regard to the revised German Safety Standard Series KTA 2201

Principles governing the Seismic Design of Nuclear Power Plants with regard to the revised German Safety Standard Series KTA 2201

... each nuclear power plant regarding the inspection ...the plant corresponds to ...the plant and register the earthquake time histories for a further comparison with design ...

8

Seismic analysis for a boron meter detector used in nuclear power plant

Seismic analysis for a boron meter detector used in nuclear power plant

... in nuclear power plant need to meet the requirements of corresponding nuclear safety ...all nuclear class equipment under seismic loads should be carried out during their design ...

6

Assessment and Management of Aging of Nuclear  Power Plant Safety-Related Structures (D457)

Assessment and Management of Aging of Nuclear Power Plant Safety-Related Structures (D457)

... Whenever damage is detected, corrective actions are taken to identify and eliminate the source of the problem and thereby halt the degradation process. When significant containment metallic pressure boundary wall ...

8

Impact of a Disaster on Land Price: Evidence from Fukushima Nuclear Power Plant Accident

Impact of a Disaster on Land Price: Evidence from Fukushima Nuclear Power Plant Accident

... The Great East Japan Earthquake, which occurred on March 11, 2011, triggered the Fukushima nuclear power plant accident. This study estimates the economic damage caused by the radioactive ...

33

A Study of Risk Analysis Methodology Selection for the External Hazards

A Study of Risk Analysis Methodology Selection for the External Hazards

... to nuclear power plants ( “plants” ) and specifies the procedures for selecting proper risk assessment methods concerning such external hazards in terms of their scenario, frequency and effects on ...

10

Fukushima Nuclear Power Plant Accident and Nuclear Physicists

Fukushima Nuclear Power Plant Accident and Nuclear Physicists

... The Fukushima Dai-ichi Nuclear Power Plant has six reactors, No. 1-6. Tsunami came to the plant around 16:00, which is about an hour after the first impact of the earthquake. The height of ...

10

Show all 10000 documents...