• No results found

pullout load

Bond behavior of fiber reinforced polymer bars under direct pullout conditions

Bond behavior of fiber reinforced polymer bars under direct pullout conditions

... > 30 MPa), it is believed that the recorded residual bond stress, shown in Fig. 4, does not necessarily represent the real value of frictional stress developed at the failure interface. This is due to the fact that ...

46

Pullout Capacity of Piles in Collapsible Soil

Pullout Capacity of Piles in Collapsible Soil

... to pullout load and embedded in gypseous soils considering the dry and soaked soil case for 24 hour by using laboratory model fabricated for that ...

6

Pullout behaviour of GFRP bars with anchor head in geopolymer concrete

Pullout behaviour of GFRP bars with anchor head in geopolymer concrete

... the pullout load increased proportionally with the ...maximum load that indicated the weakening of the sand coating’s bond resistance due to wider ...

20

Headed Anchor/Engineered Cementitious Composites (ECC) Pullout Behavior

Headed Anchor/Engineered Cementitious Composites (ECC) Pullout Behavior

... tensile load was examined experimentally and ...anchor pullout performance were used to verify the numerical ...anchor pullout behavior was clarified ...of load and displacement ...the ...

13

Pullout Capacity of Plate Anchors with Coaxial Geotextile Reinforcement

Pullout Capacity of Plate Anchors with Coaxial Geotextile Reinforcement

... the pullout load horizontal plate anchors are commonly used. Pullout capacities of shallow plate anchors are limited and to resist higher applied pulling load, capacity of anchor needs to be ...

11

Pull-Out Behaviour of Hooked End Steel Fibres Embedded in Ultra-high Performance Mortar with Various W/B Ratios

Pull-Out Behaviour of Hooked End Steel Fibres Embedded in Ultra-high Performance Mortar with Various W/B Ratios

... to pullout behaviour, a quantitative account for hook mechanisms has been ...of pullout load due to complete deformation and straightening of the end ...total pullout work is found to be lower ...

13

Statistical-Numerical Analysis for Pullout Tests of Ground Anchors

Statistical-Numerical Analysis for Pullout Tests of Ground Anchors

... anchor pullout load tests (ULS) have been per- formed for three high-pressure grouted anchors in the ex- perimental site in Czech Republic ...mum pullout forces magnitudes ...

9

Pullout Capacity and Bond Behaviour of Headed Reinforcement in concrete

Pullout Capacity and Bond Behaviour of Headed Reinforcement in concrete

... The load at which the cylindrical specimens break in different modes is taken as maximum Pullout Load (P n ) and bond stress is calculated by the formula ...

6

PULLOUT CAPACITY OF HORIZONTAL AND INCLINED PLATE ANCHORS IN CLAYEY SOILS

PULLOUT CAPACITY OF HORIZONTAL AND INCLINED PLATE ANCHORS IN CLAYEY SOILS

... the pullout capacity of horizontal anchors in undrained ...ultimate pullout load were obtained by using a newly developed three-dimensional numerical procedure based on a finite-element formulation ...

8

Pullout Behaviour of Different Types of Steel Fibres Embedded in Magnesium Phosphate Cementitious Matrix

Pullout Behaviour of Different Types of Steel Fibres Embedded in Magnesium Phosphate Cementitious Matrix

... the pullout load dropped significantly after the end hook straightened up, the crimped fibres (C-A) maintained a high pullout load resistance up to very high ...The pullout load ...

17

Experimental and FDM Study on Geogrid-Soil Interaction by Reformed Direct Shear Test Apparatus

Experimental and FDM Study on Geogrid-Soil Interaction by Reformed Direct Shear Test Apparatus

... resistance and the geogrid-soil interaction. In the other normal stresses, the strength mobilization increases as the geogrids strength increase. This phenomenon may be for the reason that the soil grains in the geogrid ...

16

Pullout resistance of granular anchors in clay for undrained condition

Pullout resistance of granular anchors in clay for undrained condition

... However, for GA5 and GA8 L D ≥ 8.7, Figure 10g, h, significant bulging of the columns was predicted over a length of ~ 2–3 Do from the column base, with  r values of ~ 35% predicted fo[r] ...

31

Individual and Intra-Individual Differences in Interest during Instrumental Music Classes in Suburban High Schools

Individual and Intra-Individual Differences in Interest during Instrumental Music Classes in Suburban High Schools

... intervention to increase the reading skills (decoding, linguistic comprehension, and reading.. comprehension) of secondary students who are served in a pullout special education model, a[r] ...

200

Pullout strength of reinserted pedicle screws using the previous entry point and trajectory

Pullout strength of reinserted pedicle screws using the previous entry point and trajectory

... strength of reinserted screws was 2.5% less than that of control screws. But in group C, the reinserted screws were superior in average pullout strength. Stiffness was also an important outcome. In the 3 groups, ...

6

Study on Ultimate Pullout Force of  Grouting Anchors of the  Anchor Pull Retaining Wall

Study on Ultimate Pullout Force of Grouting Anchors of the Anchor Pull Retaining Wall

... The result of numerical simulation at upper Loading was shown in Figure 7 and Figure 8. The top load on the retaining wall is absolutely uniform, so the regularity of the axial force was better than the measured ...

6

Anchorage Mechanism for Ocean Compressed Air Energy Storage Including Gravity-based and Suction Caissons Approaches.

Anchorage Mechanism for Ocean Compressed Air Energy Storage Including Gravity-based and Suction Caissons Approaches.

... and pullout capacity considering the vacuum occurrence are smaller than that without considering vacuum occurrence; when h tran   h h cr , the predictions of suction pressure and pullout capacity ...

190

A Review  Shear and Pullout behaviours of steel Fiber Reinforced Concrete on Elevated Temperature

A Review Shear and Pullout behaviours of steel Fiber Reinforced Concrete on Elevated Temperature

... and pullout behaviours of steel fiber reinforced concrete (SFRC) with partial replacements of fine aggregate with copper slag subjected to elevated ...and pullout behaviours in the elevated temperatures on ...

6

Surface Friction on Pullout Capacity of Pile in Sandy Soil

Surface Friction on Pullout Capacity of Pile in Sandy Soil

... Pile-soil interaction problem is very complicated. The phenomenon is a function of pile material, its surface characteristics, length, diameter, soil-pile friction angle, geometry of group, methods of installation and ...

5

Influence of welded depth and CuCl2 pretreated dowels on wood dowel welding

Influence of welded depth and CuCl2 pretreated dowels on wood dowel welding

... According to this Eq. 21, the differences between cal- culated values and test values are shown in Table 7. All the data of five depths were fit accurately with the errors less than 0.44%. In the future study, the depth ...

10

Experimental study on z-pin bridging law by pullout test

Experimental study on z-pin bridging law by pullout test

... This paper presents an experimental study on the evaluation of bridging law for a z-pin. The relationship between the z-pin bridging force and its displacement was measured by z-pin pullout tests. The tests were ...

28

Show all 10000 documents...