Push-out tests

Push Out Tests of Cold Formed Steel and Concrete Slab

Push Out Tests of Cold Formed Steel and Concrete Slab

... the push out tests which were carried out to examine shear transfer between the concrete slab and the cold formed beam section ...Four push out tests were carried ...

10

Push-Out Tests for a Novel Prefabricated Steel-Concrete Composite Shallow Flooring System

Push-Out Tests for a Novel Prefabricated Steel-Concrete Composite Shallow Flooring System

... Push-out tests were carried out in the Heavy Structures Laboratory of the University of Leeds. The test rig and set up are shown in Figure 4. One identical hydraulic jack was used to apply a ...

6

Push-out tests and analytical study of shear transfer mechanisms in composite shallow cellular floor beams

Push-out tests and analytical study of shear transfer mechanisms in composite shallow cellular floor beams

... carried out on the results of push-out tests with the aim of establishing a calculation method for the shear resistance of the shear connection used in the composite shallow cellular floor ...

43

Push-out tests and analytical study of shear transfer mechanisms in composite shallow cellular floor beams

Push-out tests and analytical study of shear transfer mechanisms in composite shallow cellular floor beams

... Permanent repository link: http://openaccess.city.ac.uk/14018/ Link to published version: http://dx.doi.org/10.1016/j.jcsr.2013.05.007 Copyright and reuse: City Research Online aims to m[r] ...

6

Effect of various factors on the push out bond strength of mta based root canal sealers - a systematic review

Effect of various factors on the push out bond strength of mta based root canal sealers - a systematic review

... Various tests are employed for the same which include shear bond strength, microtensile, pull-out and push-out ...and push-out ...contrary, push-out bond strength ...

6

Experimental Investigation on Bond Strength in Coventional Concrete Filled Steel Tube - A Review

Experimental Investigation on Bond Strength in Coventional Concrete Filled Steel Tube - A Review

... of push-out tests on circular CFST specimens going to be conducted, and the main parameters considered in the test program were: (a) cross-sectional dimension; (b) steel type (galvanized steel); (c) ...

7

Evaluation of the Shear Strength of  Perfobond Rib Connectors in Ultra High  Performance Concrete

Evaluation of the Shear Strength of Perfobond Rib Connectors in Ultra High Performance Concrete

... On the behavior of stud connector in high strength concrete, An and Cederwall [8] conducted push-out tests to understand the strength of a stud depends on the concrete property with compressive ...

12

Effect of Layering Technique on Push-Out Bond Strength of Composite Resin to Intracanal Dentin of Primary Anterior Teeth

Effect of Layering Technique on Push-Out Bond Strength of Composite Resin to Intracanal Dentin of Primary Anterior Teeth

... 12- Soares CJ, Santana FR, Castro CG, Santos-Filho PC, Soares PV, Qian F, et al. Finite element analysis and bond strength of a glass post to intraradicular dentin: comparison between microtensile and push- ...

9

Testing and Numerical Modelling of Steel-Concrete-Steel with Stud Bolts Connectors Subject to Push-Out Loading

Testing and Numerical Modelling of Steel-Concrete-Steel with Stud Bolts Connectors Subject to Push-Out Loading

... ABAQUS/Standard Software was the first option for model analysis that is mainly suitable for static analysis. Notwithstanding , concrete material model using this software makes the analysis divergent in a small part of ...

20

The resistances of stud shear connectors with profiled sheeting

The resistances of stud shear connectors with profiled sheeting

... As push-out tests are the major method to study the behaviour of stud connectors in composite beams, the number of studs per specimen should reflect the minimum possible number per shear[r] ...

230

Experimental study and analytical study of push-out shear tests in Ultra Shallow Floor Beams

Experimental study and analytical study of push-out shear tests in Ultra Shallow Floor Beams

... As the floors are being cast, the in-situ concrete passes through the web openings, which may or may not include a tie-bar or duct. This concrete plug and tie bar forms a unique mechanism for transferring longitudinal ...

9

Comparative evaluation of push-out bond strength of two different root end repair material

Comparative evaluation of push-out bond strength of two different root end repair material

... Melek Akman et al., in 2015 evaluated the effect of intra-canal medicaments on push-out bond strength of Biodentine and DiaRoot Bioaggregate when used as apical plug. Combination of Metronidazole- ...

105

The Investigation of the Chronical Effects of Static Flexibility Exercises on Some Biomotoric and Physiological Parameters

The Investigation of the Chronical Effects of Static Flexibility Exercises on Some Biomotoric and Physiological Parameters

... The content of the study was explained to the participant students in detail before the pre-test measurements. Besides, all the participants were warned not to do exercise heavily on the day before the measurement. ...

8

Analysis of failure behavior of shear connection in push-out specimen by three-dimensional stress analysis

Analysis of failure behavior of shear connection in push-out specimen by three-dimensional stress analysis

... the push-out ...the push- out specimen has diameter of 19 mm and tensile strength of 550 MPa, and the concrete member develops compressive strength of 110 MPa ...

9

The Effect of Different Irrigation Regiments on the Push out Bond Strength of MTA Fillapex Sealer to Dentin

The Effect of Different Irrigation Regiments on the Push out Bond Strength of MTA Fillapex Sealer to Dentin

... The adhesive properties of endodontic sealers are important as gutta-percha does not bond to root dentin and is used in conjunction with a root canal sealer. The risk of filling detachment from dentin during restorative ...

8

A queueing model of a bufferless synchronous Clos ATM switch with head-of-line priority and push-out

A queueing model of a bufferless synchronous Clos ATM switch with head-of-line priority and push-out

... We also obtain the mean waiting time of a low priority cell given that it entered the queue and it got served.. The main vehicle for obtaining these results is the one dimensional random[r] ...

31

Anti-Gay Legislation in Russia: Western Perspectives

Anti-Gay Legislation in Russia: Western Perspectives

... law allows police officers to take people into custody and detain them for 14 days if they are suspected of being gay or pro-gay. The final law Fierstein calls out classifies “homosexual propaganda” as illegal. ...

10

State of Art Review of Experimental Pull Out Tests

State of Art Review of Experimental Pull Out Tests

... pull out tests require careful attention with respect to embedment ...carry out experiments; on pull out specimen, manufactured from locally available construction material, sourced at site ...

5

Effect of Etching Time and Preparation on Push-Out Bond Strength of Composite to Intracanal Dentin of Primary Anterior Teeth

Effect of Etching Time and Preparation on Push-Out Bond Strength of Composite to Intracanal Dentin of Primary Anterior Teeth

... distance of 2mm from the tooth surface. Next, all samples were immersed in distilled water and stored in an incubator at 37°C (MalekKhosravi, Tehran, Iran) for 24 hours. Samples were then mounted in clear acrylic resin ...

8

Influence of muscle fitness test performance on metabolic risk factors among adolescent girls

Influence of muscle fitness test performance on metabolic risk factors among adolescent girls

... A total of 229 girls (aged 12-15 years old) comprised the sample of this study. As exclusion criteria girls were asked if they have some physical constraint or medical conditions that do not allow them to participate on ...

7