• No results found

reaction force

The Effect of Rocker Shoe on the Ground Reaction Force Parameters in Patients with Rheumatoid Arthritis

The Effect of Rocker Shoe on the Ground Reaction Force Parameters in Patients with Rheumatoid Arthritis

... Objectives: Foot and ankle problems are common complications in rheumatoid arthritis disease. Gait pattern such as normal foot and ankle rocker is impaired in patients with rheumatoid arthritis. Rocker sole as an ...

7

Gait Ground Reaction Force Sensors Selection Based on ROC Curve Evaluation

Gait Ground Reaction Force Sensors Selection Based on ROC Curve Evaluation

... nals from all sensors as the most important, however, its clearly shown that sensor 5 is the most important sensor (AUC = 0.9) to consider in building acquisition system to acquire data for analyses. Figure 4 shows the ...

7

Measuring ground reaction force and quantifying variability in jumping and bobbing actions

Measuring ground reaction force and quantifying variability in jumping and bobbing actions

... a force plate were employed to characterize the peak ground reaction force, frequency of the activity, range of body movement, and dynamic loading factors for at least first three ...ground ...

15

Comparison of ground reaction force during different angle of squatting

Comparison of ground reaction force during different angle of squatting

... ground reaction force is one of the major issues that is ...ground reaction force (GRF) is a force of equal magnitude exerted on the opposite direction from the ground up to the foot ...

10

The Influence of Additional Surface on Force Platform’s Ground Reaction Force Data During Walking and Running

The Influence of Additional Surface on Force Platform’s Ground Reaction Force Data During Walking and Running

... ground reaction force during walking and running in two conditions were ...the force plate ...a force plate surface that was covered with a futsal court ...the force platform, in this ...

5

Relationships of the expertise level of taekwondo athletes with electromyographic, kinematic and ground reaction force performance indicators during the dollyo chagui kick

Relationships of the expertise level of taekwondo athletes with electromyographic, kinematic and ground reaction force performance indicators during the dollyo chagui kick

... opposite force generation related to the other plotted EMG profiles (for example, GL is negative because its muscle function is the plantar flexion, with negative ...

11

Quadriceps force and anterior tibial force occur obviously later than vertical ground reaction force: a simulation study

Quadriceps force and anterior tibial force occur obviously later than vertical ground reaction force: a simulation study

... quadriceps force, and that depended on the knee flexion ...tibial force, altering the vector of the compressive load anteriorly on the tibial ...ground reaction force on the anterior tibial ...

8

Segmental contributions to the ground reaction force in the single support phase of gait

Segmental contributions to the ground reaction force in the single support phase of gait

... Abstract. An inverse dynamics model for the single support (SS) phase of gait is developed to study segmental contributions to the ground reaction force (GRF). With segmental orientations as the generalized ...

16

Modelling the effect of the radiation reaction force on the acceleration of ultra-thin foils

Modelling the effect of the radiation reaction force on the acceleration of ultra-thin foils

... radiation reaction force on radiation pressure acceleration is ...radiation reaction causes a decrease in the target velocity during the interaction of an ultra-intense laser pulse with a solid ...

10

Mechanical stimulation of the foot sole in a supine position for ground reaction force simulation

Mechanical stimulation of the foot sole in a supine position for ground reaction force simulation

... ground reaction force within the stance phase, ...simplified force pattern in Figure 4(b) was adopted to simulate the ground reaction forces that occur during ...

13

Evaluation of vertical ground reaction force during walking in patients with multiple sclerosis

Evaluation of vertical ground reaction force during walking in patients with multiple sclerosis

... ground reaction force was measured in all the participants throughout the times of weight transfer in the three components of heel contact, mid stance, and terminal stance of stance phase while they were ...

6

Mechanical stimulation of the foot sole in a supine position for ground reaction force simulation

Mechanical stimulation of the foot sole in a supine position for ground reaction force simulation

... The force rising time was found to be an important issue to consider during simulation of the ground reaction ...stimulation force with a rising time of ...ground force, which serves as a ...

37

Influence of radiation reaction force on ultraintense laser-driven ion acceleration

Influence of radiation reaction force on ultraintense laser-driven ion acceleration

... RR force and the synchrotron radiation [10,20], is ...RR force increases or decreases the ion ...RR force on ion acceleration may be reduced in simulations at higher ...

8

System of gait analysis based on ground reaction force assessment

System of gait analysis based on ground reaction force assessment

... a force plate has three components acting in directions: Fx – mediolat- eral (ML), Fy – anteroposterior (AP), and Fz – verti- cal, see Figure ...recorded force-time ...of force-time curve ...

7

Motor control of locomotor hindlimb posture in the American alligator
(Alligator mississippiensis)

Motor control of locomotor hindlimb posture in the American alligator (Alligator mississippiensis)

... ground reaction force during upright steps in alligators (Blob and Biewener, 2001), an increase in GAST burst intensity is clearly explained as a mechanism for maintaining the equilibrium of ankle joint ...

14

Preliminary in vivo evaluation of a needle insertion manipulator for central venous catheterization

Preliminary in vivo evaluation of a needle insertion manipulator for central venous catheterization

... In an in vivo experiment conducted on a porcine, we evaluated the needle insertion manipulator developed in our previous research. The experimental results confirmed a high venous placement rate of 80% for puncture under ...

7

Dynamics of gecko locomotion: a force measuring array to measure 3D reaction forces

Dynamics of gecko locomotion: a force measuring array to measure 3D reaction forces

... 3D reaction force measured by the force platform ...the reaction force measured by a force platform with the corresponding locomotion ...fore–aft reaction forces were ...

6

Online Full Text

Online Full Text

... The reaction force and reaction torque on the distal phalange at the joint of the pin (connecting link 3 and distal phalange) and the distal phalange can be ...The reaction force and ...

7

A stochastic biomechanical model for risk and risk foctors of sustaining non-contact ACL injuries

A stochastic biomechanical model for risk and risk foctors of sustaining non-contact ACL injuries

... shear force, knee extension moment, and valgus moment, and smaller knee flexion angle at the peak proximal tibial anterior shear force during the landing phase of the stop-jump task than men ...ground ...

227

Trabecular bone in the bird knee responds with high sensitivity to changes in load orientation

Trabecular bone in the bird knee responds with high sensitivity to changes in load orientation

... unimodal force traces (N=10 strides) and one of the peaks in bimodal force traces (N=6 strides), foot-off, defined as the first kinematic frame in which the TPj rises from its lowest point ...joint ...

9

Show all 10000 documents...

Related subjects