• No results found

time-of-flight experiments

A NANOSECOND TIME CODER WITH GREAT ANALYSIS RANGE FOR TIME Of FLIGHT EXPERIMENTS  EUR 491 e

A NANOSECOND TIME CODER WITH GREAT ANALYSIS RANGE FOR TIME Of FLIGHT EXPERIMENTS EUR 491 e

... A NANOSECOND TIME CODER WITH GREAT ANALYSIS RANGE FOR TIME-OF-FLIGHT EXPERIMENTS SUMMARY A first version of a nanosecond time coder for "on line" and "off-line" time-of-flight analysis w[r] ...

26

Thermo-Mechanical Design of a Photoneutron Source for Time-of-Flight Experiments

Thermo-Mechanical Design of a Photoneutron Source for Time-of-Flight Experiments

... A sketch of the photoneutron source driven by the ps-pulsed electron beam of ELBE is shown in Fig. 1. The electron beam will be directed to a liquid lead radiator where bremsstrahlung photons are produced, which in turn ...

11

A Timecoder for Neutron Time of Flight Experiments  EUR 4835

A Timecoder for Neutron Time of Flight Experiments EUR 4835

... In regions where no events have to be stored, address counting is inhibited which results in optimal use of the 4096 output channels 12 bits.. The deadtime of the coder together with a b[r] ...

26

Neutron induced fission of 237Np – status, challenges and opportunities

Neutron induced fission of 237Np – status, challenges and opportunities

... uncertainties appropriate for nuclear reactor applications. This is true for all of the available incident neutron energy regions. The data from the sole experiment on the fluctuation of fission γ-ray yields from ...

6

Experiments on aircraft flight parameter detection by on skin sensors

Experiments on aircraft flight parameter detection by on skin sensors

... Having discussed the usage of function F for the estimation of Φ , it is worth considering the determination of F itself. Obvi- ously, F depends on the particular shape of the aerodynamic surfaces on which the sensors ...

11

Timing of elevator muscle activity during climbing in free locust flight

Timing of elevator muscle activity during climbing in free locust flight

... All experiments were carried out using adult female Schistocerca gregaria Forskål (15–21 days ...Individual flight sequences were investigated in a room measuring 10 ...the flight experiments. ...

12

Silicon Revisited: Understanding Pure Phonon Anharmonicity and the Effects on Thermophysical Properties

Silicon Revisited: Understanding Pure Phonon Anharmonicity and the Effects on Thermophysical Properties

... The experiments used a high-purity single crystal of silicon (mass ≈ ...geometry time-of-flight inelastic neutron scattering spectrometer (ARCS) [25] at the Spallation Neutron Source at Oak Ridge ...

116

Morphological specialization influences nectar extraction efficiency of sympatric nectar feeding bats

Morphological specialization influences nectar extraction efficiency of sympatric nectar feeding bats

... In flight cage experiments with artificial flowers, at deeper nectar levels all species showed a distinct decrease in the amount of nectar extracted per visit and an increase in the time spent ...

8

The Respiratory Exchange of the Desert Locust (Schistocerca Gregaria) before, During and After Flight

The Respiratory Exchange of the Desert Locust (Schistocerca Gregaria) before, During and After Flight

... In order to obtain a general expression of the increase in metabolic rate after flight, the oxygen consumption was plotted against time in the experiments in which the same animals were [r] ...

14

Multi gap Resistive Plate Chambers for Time of Flight applications

Multi gap Resistive Plate Chambers for Time of Flight applications

... of Flight (ToF) system is an essential part for particle identification (PID) [1] in particle and high energy physics ...the time required to travel from the interaction point to the time of ...

18

Pulsed Neutrons and Their Utilization  EUR 5046

Pulsed Neutrons and Their Utilization EUR 5046

... The design criteria for high resolution time of flight spectrometers for coherent and incoherent elastic and inelastic scattering experiments are enumerated.. KEYWORDS MEETINGS RESOLUTIO[r] ...

80

A new time-of-flight mass spectrometer.

A new time-of-flight mass spectrometer.

... ments. A wealth of other time of flight instruments (Duckworth, 1958 ) have been developed which make use of retarding poten­ tials, r.f. voltages applied to grids and various arrange­ ments of these grids. ...

67

Recent developments in time-of-flight PET

Recent developments in time-of-flight PET

... The most natural format for TOF-PET is to store the data as a list of events, with the necessary details of each event (called listmode data). This allows to use 3D listmode TOF MLEM. Normalization, dead time, and ...

30

Low computational SLAM for an autonomous indoor aerial inspection vehicle

Low computational SLAM for an autonomous indoor aerial inspection vehicle

... Error handling is an important aspect in all software, especially mission critical soft- ware such as the software on-board the Hexakopter. The error detection capabilities of the Hexakopter can be split into two ...

254

Time of flight diffraction and imaging (TOFDI)

Time of flight diffraction and imaging (TOFDI)

... the time differential of the magnetostrictive force, as it is the absolute value of the magnetic field that determines the magnetostriction, not the ...a time varying field changing the overall magnetic ...

197

Anatomical variations and dimensions of arteries in the anterior part of the circle of Willis

Anatomical variations and dimensions of arteries in the anterior part of the circle of Willis

... The morphological variations and diameter differ- ences demonstrated in our study providing an impor- tant reference value for the 3D time-of-flight MRA. Our findings show that the configuration of the CW ...

8

Preparing the leg for ground contact in running: the contribution of feed forward and visual feedback

Preparing the leg for ground contact in running: the contribution of feed forward and visual feedback

... While running on uneven ground, humans are able to negotiate visible but also camouflaged changes in ground level. Previous studies have shown that the leg kinematics before touch down change with ground level. The ...

7

Normal Variants of Circle of Willis in MR Angiography among Puducherry Population

Normal Variants of Circle of Willis in MR Angiography among Puducherry Population

... dimensional time of flight Magnetic resonance ...dimensional time of flight transaxial acquisition which was used for examination of all patients with the following parameters (TR /TE /FA (25 ...

6

Focus on Advances in Shape from Focus

Focus on Advances in Shape from Focus

... Seong-O Shim, Tae-Sun Choi [4] proposed algorithm tries to find the combination of pixel frames which produce s maxi mum focus measure computed over pixels lying on those frames. To reduce the high computational ...

8

A Study of T = 1, T = 3/2, and T = 2 States in Some Light Nuclei Using (He^3,n) Reactions

A Study of T = 1, T = 3/2, and T = 2 States in Some Light Nuclei Using (He^3,n) Reactions

... Among the factors which contribute to the resolution are beam energy resolution, beam burst length, electronic resolution, the total neutron flight time, the flight time of neutrons thro[r] ...

213

Show all 10000 documents...