• No results found

track detector

Calibration of UV-Radiation Dose with Irradiation Time for CR-39 Track Detector by Using UV-visible Spectrophotometer

Calibration of UV-Radiation Dose with Irradiation Time for CR-39 Track Detector by Using UV-visible Spectrophotometer

... nuclear track detector in the form of sheets with thickness 1200 µm , obtained from TASTRAK ( Pershore Moulding , Track Analysis System Ltd ...CR-39 detector was irradiated by two ultraviolet ...

5

Measurement of Indoor Radon Concentration in Bahraich and Barabanki District of Eastern U P  using LR 115 Type II Plastic Track Detector (SSNTDS)

Measurement of Indoor Radon Concentration in Bahraich and Barabanki District of Eastern U P using LR 115 Type II Plastic Track Detector (SSNTDS)

... cane etc cultivation and very fertile. The Dumat or loam is also fertile soil, ideal for cultivation of various types of crops. This is the reason for high crop yields in the district. The soil cover is generally shallow ...

10

A Novel Detection Technique for Nuclear Radiations: Solid State Nuclear Track Detector, CR 39: A Review

A Novel Detection Technique for Nuclear Radiations: Solid State Nuclear Track Detector, CR 39: A Review

... Nuclear Track Detectors have been aligned for identification of alpha-particles and protons in a high neutron transition ...plastic detector has a place with natural indicators; it is a sort of multi-carbon ...

5

A Review Article on the Study of Radon and Thoron Concentration using Solid State Nuclear Track Detector

A Review Article on the Study of Radon and Thoron Concentration using Solid State Nuclear Track Detector

... Sandeep Kansal et al., [2011], examined the indoor radon fixation in the dwelling of Haryana, India. Concentration of radon considers were completed in 100 dwellings of 20 towns in Haryana areas on west side, utilizing ...

5

Determination of Alpha Rates Emitted from Animal Bones Using CN-85 Nuclear Track Detector

Determination of Alpha Rates Emitted from Animal Bones Using CN-85 Nuclear Track Detector

... nuclear track detector is based on the fact that a heavy charged particle will cause extensive ionization of the material when it passes through a medium ...nuclear track detectors until now, there ...

5

Microstructural Investigation of PM 355 Nuclear Track Detector Subjected to Low Dose Gamma Irradiation: A Positron Annihilation Lifetime Study

Microstructural Investigation of PM 355 Nuclear Track Detector Subjected to Low Dose Gamma Irradiation: A Positron Annihilation Lifetime Study

... Samples of the PM-355 polymeric solid state nuclear track detector were exposed to low gamma absorbed doses from 1 kGy (0.1 Mrad) up to 9 kGy (0.9 Mrad). Positron annihilation lifetime (PAL) in conjunction ...

8

Determination of Alpha Particles Concentration in Toothpaste Using CR 39 Track Detector

Determination of Alpha Particles Concentration in Toothpaste Using CR 39 Track Detector

... nuclear track detector (CR-39) of thickness 250 μm and area of about (1 × 1 cm 2 ...nuclear track detector (CR-39) (see Figure 1) at distance of 5 cm from the neutron source (Am-Be), with ...

5

Studying Different Etching Methods Using CR 39 Nuclear Track Detector

Studying Different Etching Methods Using CR 39 Nuclear Track Detector

... The track density when etching with water bath is increased between the etching times (60 - 150 ...the track density would appears at etching time range (20 - 30 ...the track density would appears at ...

9

Radon Concentration Measurements in  Gattar Uranium Prospect, Northern  Eastern Desert, Egypt

Radon Concentration Measurements in Gattar Uranium Prospect, Northern Eastern Desert, Egypt

... The concentration of Radon in mines varies tremendously according to the country rock, type of mineralization and area. Ventilation is also an impor- tant factor. The absence of ventilation in mines tends to allow a ...

11

Analysis of Nuclear Track Parameters of CN 85 Detector Irradiated to Thermal Neutrons by Using MATLAB Program

Analysis of Nuclear Track Parameters of CN 85 Detector Irradiated to Thermal Neutrons by Using MATLAB Program

... for track recognition and track parameters measurements from images of the solid state nuclear track detectors type ...nuclear track detector-SSNTD type ...

8

Levels of natural radioactivity in environment in residential area of Moradabad District, Western Uttar Pradesh

Levels of natural radioactivity in environment in residential area of Moradabad District, Western Uttar Pradesh

... of detector film ...mode detector keeps track of radon and thoron gases along with their progeny concentrations, while the filter mode focuses on the radon and thoron gases and the membrane mode, the ...

7

Nuclear Track Detectors for Relativistic Nuclear  Fragmentation Studies: Comparison with Other  Competitive Techniques

Nuclear Track Detectors for Relativistic Nuclear Fragmentation Studies: Comparison with Other Competitive Techniques

... ABSTRACT The potential of the high resolution nuclear track detector NTD CR-39 is examined carefully for the measurement of relativistic nuclear projectile fragmentation cross sections a[r] ...

11

Improvement of charge resolution for trans-iron nuclei (Z ≥ 30) in CR-39 plastic nuclear track detectors using trajectory tracing technique

Improvement of charge resolution for trans-iron nuclei (Z ≥ 30) in CR-39 plastic nuclear track detectors using trajectory tracing technique

... nuclear track detector (PNTD) is essential as a part of an effort to our future mea- surements of the projectile charge changing cross sections for galactic cosmic ray nuclei, but extremely ...nuclear ...

6

Diagnose and investigation of angular distribution of copper plasma ions

Diagnose and investigation of angular distribution of copper plasma ions

... velocity, energy, flux and angular distribution of ions from laser induced plasma are including of Micro channel plate (MCP), Solid state nuclear track detector ([r] ...

8

Measuring Uranium Concentrations in Soil Samples of Midland Refineries Company - Doura - Baghdad – Iraq

Measuring Uranium Concentrations in Soil Samples of Midland Refineries Company - Doura - Baghdad – Iraq

... CR-39 detector technique was used, to estimate the uranium concentration from the soil in midland refineries Company (Doura refine ( , Baghdad, ...nuclear track detector type ...

6

Development of Detector Vibrating Watch Model for 100-Meter Dash Race for Visually-impaired Athletes

Development of Detector Vibrating Watch Model for 100-Meter Dash Race for Visually-impaired Athletes

... the track without an assistant is needed. The use of detector vibrating watch could help visually-impaired athletes to directly determine their position and when would they arrive to finish ...of ...

14

Compressed baryonic matter experiment at FAIR

Compressed baryonic matter experiment at FAIR

... CBM detector will record both proton-nucleus and nucleus-nucleus collisions at beam energies up to 45 ...novel detector systems, trigger and data acquisition concepts as well as in- novative real-time ...

7

ABSTRACT: This paper proposes designing of railway crack detector (RCD) using IR sensors for the railway track

ABSTRACT: This paper proposes designing of railway crack detector (RCD) using IR sensors for the railway track

... The proposed system will automatically detects the cracks without any man power. In the proposed system we used IR sensors to detect the cracks in the tracks. We used the micro controller (ATmega328) to control the ...

6

Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector

Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector

... 1.4, predicted by SRIM [53] for events of 500 to 6000 NIPs. It can be seen that each of the axial range component parameters shown in table 1 returned a larger value where the MND is oriented in a direction parallel to ...

18

The performance of AGATA: From the LNL demonstrator to the GANIL setup

The performance of AGATA: From the LNL demonstrator to the GANIL setup

... Figure 1: Response of the core preamplifier of an AGATA HPGe detector to an average 30 kHz count rate, during an in–beam experiment (in red). The ampli- tudes extracted from the signals when using a trapezoidal ...

8

Show all 5420 documents...