• No results found

transmission line parameters modelling

Saturable and dispersive parity time symmetric directional coupler: a transmission line modelling study

Saturable and dispersive parity time symmetric directional coupler: a transmission line modelling study

... following parameters: the core refractive index is n ' g  3 ...gain/loss parameters are  0   2116 ...following parameters: the spatially mesh has  x   y  7 ...

7

Modelling the response of transformer winding for deformation analysis

Modelling the response of transformer winding for deformation analysis

... electrical parameters, which are capacitance, C, conductance, G resistance, R, self- inductance, L and mutual inductance, ...electrical parameters, there are several methods to model the transformer ...

6

FUZZY BASED MODELLING OF S-IPFC WITHOUT DC LINK FOR POWER FLOW CONTROL IN THREE PHASE TRANSMISSION LINE

FUZZY BASED MODELLING OF S-IPFC WITHOUT DC LINK FOR POWER FLOW CONTROL IN THREE PHASE TRANSMISSION LINE

... the transmission network and these demands continue to increase because of the increasing number of non utility generators and intensified competition among ...existing transmission networks through ...

7

Coupled parity time symmetric cavities: results from transmission line modelling simulations

Coupled parity time symmetric cavities: results from transmission line modelling simulations

... between the PT resonators with dispersive and ideal gain/loss material model both before and after the threshold, with only minor discrepancies around the threshold point. The imaginary parts of the eigenfrequenices for ...

5

Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)

Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)

... Based on existing models and previous studies, the writing will focus on a comparison of data between the modelling used. Only a few studies have been made detailing a model as a general study gives a clear ...

37

Modelling and Simulation of Fuzzy Controlled SVC for Long Transmission Line

Modelling and Simulation of Fuzzy Controlled SVC for Long Transmission Line

... two parameters, delay angle α and conduction angle σ are equivalent and therefore TCR can be characterized by either of them; their use is simply a matter of ...

7

Dynamic Modelling and Obstacle Avoidance for Cable Maneuvering Robot - In application to Transmission line Inspection robots

Dynamic Modelling and Obstacle Avoidance for Cable Maneuvering Robot - In application to Transmission line Inspection robots

... The design framework involved with these kind of robot must enable them, by adapting to different geometrical environments to avoid obstacles, slope traversing and inertial compensation. Which is achieved by intelligent ...

5

Modelling antennas in outer space using the boundary element unstructured transmission line (BEUT) method

Modelling antennas in outer space using the boundary element unstructured transmission line (BEUT) method

... material parameters modelled using triangles, with each triangle representing the material parameter of its dis- cretized region as stipulated in the UTLM method de- scribed by Sewell et ...electrical ...

5

Modelling of Ultra High Voltage Transmission Line Faults Detection and Identification by Using Matlab Simulation

Modelling of Ultra High Voltage Transmission Line Faults Detection and Identification by Using Matlab Simulation

... UHV transmission lines there are different types of fault occurs in electrical power system then in the process of transmission line fault analysis and detection, determination of bus voltage and the ...

11

A Modelling of 440 KV EHV Transmission Line Faults identified and Analysis by Using MATLAB Simulation

A Modelling of 440 KV EHV Transmission Line Faults identified and Analysis by Using MATLAB Simulation

... EHV transmission lines there are different types of fault occurs in electrical power system then in the process of transmission line fault analysis and detection, determination of bus voltage and the ...

8

Preferred Economic Dispatch of Thermal Power Units

Preferred Economic Dispatch of Thermal Power Units

... cost parameters of the generating units. Generally, the parameters are subjected to transform due to aging process and other external ...the parameters associated with the transmission ...

23

Transmission line modelling for multi-gigabit serial interfaces

Transmission line modelling for multi-gigabit serial interfaces

... the transmission speeds increase it is becoming increasingly more difficult in terms of time and money, to measure the integrity of the received signals and engineers are reliant on simulation to ensure low bit ...

13

Develop A 5.8ghz Antenna Using Microstrip Technologies

Develop A 5.8ghz Antenna Using Microstrip Technologies

... Literature review is one of the processes for developing a 5.8GHz Microstrip Antenna. As for this project, the literature review is explaining on the antenna and the basic antenna operation, microstrip antenna, ...

24

Various Analytical Methods on Transmission Price Allocation in a Restructured Environment of Power Systems

Various Analytical Methods on Transmission Price Allocation in a Restructured Environment of Power Systems

... the transmission provision gets a good deal of ...the transmission network ...towards transmission planning [2]. Open access demands sound transmission corridor availability for a transaction ...

6

Development of a Fuzzy Controller with UPFC’s For Damping of Oscillation in Multi-machine Integrated Power System

Development of a Fuzzy Controller with UPFC’s For Damping of Oscillation in Multi-machine Integrated Power System

... In this paper the fuzzy logic controller is used to coordinate between the various parameters of the multi- machine based FACTS power system along with the POD- UPFC as shown in the block diagram in the Fig. 4. ...

6

Power Cable Joint Model: Based on Lumped Components and Cascaded Transmission Line Approach

Power Cable Joint Model: Based on Lumped Components and Cascaded Transmission Line Approach

... cascaded transmission line model are proposed based on scattering parameters (S -parameters) measurement on a 10 kV oil-filled PILC-PILC straight cable joint in the frequency range of 300 ...

17

4. Power Flow Control By using D-FACTS Concept Through DPFC

4. Power Flow Control By using D-FACTS Concept Through DPFC

... a transmission line to deliver power depends on its ...the transmission-line impedance is inductive and proportional to the frequency, high-transmission frequencies will cause high ...

8

A Review Paper on Power Quality Improvement and Mitigation Case Study Using Distributed Power Flow Controller

A Review Paper on Power Quality Improvement and Mitigation Case Study Using Distributed Power Flow Controller

... urgent transmission and consumption of electric power effect on the performance system (FACTS) and custom power devices, affects power quality improvement [3], ...

5

Transmission Line for Broadcast Applications

Transmission Line for Broadcast Applications

... To account for this effect on the conductor, a conductivity rating of 95% should be used, resulting in an additional 1-2% increase in attenuation. When comparing manufacturer data, these issues should be reviewed for ...

5

Transmission Line Protection Principles

Transmission Line Protection Principles

... In the L90, synchronization is accomplished by synchronizing the clocks to each other rather than to a master clock. Each relay compares the phase of its clock to the phase of the other clocks and compares the frequency ...

10

Show all 10000 documents...