• No results found

viscous dampers

Assessment of capacity design of columns in steel moment resisting frames with viscous dampers

Assessment of capacity design of columns in steel moment resisting frames with viscous dampers

... Nonlinear models for the steel MRFs with and without viscous dampers are developed in OpenSees [25]. The columns are modeled as nonlinear force-based beam-column fiber elements with bilinear elastoplastic ...

21

Seismic design procedure for steel moment resisting frames with viscous dampers

Seismic design procedure for steel moment resisting frames with viscous dampers

... with viscous and viscoelastic dampers (Kasai and Fu 1998) describes the mathematical models of these systems and expressions are derived for seismic response ...with viscous and viscoelastic ...

187

Seismic design and assessment of resilient post tensioned steel frames with viscous dampers

Seismic design and assessment of resilient post tensioned steel frames with viscous dampers

... MRFs. Viscous dampers could be combined with SC-MRFs to control peak story drifts but an integrated design approach for SC-MRFs with viscous dampers has not been ...

286

Optimization of Viscous Dampers with the Influence of Soil Structure Interaction on Response of Two Adjacent 3-D Buildings under seismic load

Optimization of Viscous Dampers with the Influence of Soil Structure Interaction on Response of Two Adjacent 3-D Buildings under seismic load

... 12 viscous dampers at the floor levels with fixed base cases(no) , then by using three types of soil (stiff, medium, and soft) represented by 3D Winkler model with raft foundation system, the two adjacent ...

10

Seismic Analysis of Four Legged Telecommunication Towers using Fluid Viscous Dampers

Seismic Analysis of Four Legged Telecommunication Towers using Fluid Viscous Dampers

... Fluid viscous dampers operate on the principle of fluid flow through orifices. A stainless steel piston travels through chambers that are filled with silicone oil. The silicone oil is inert, non-flammable, ...

7

Performance of Fluid Viscous Dampers on Seismic Response of RCC Structures

Performance of Fluid Viscous Dampers on Seismic Response of RCC Structures

... predicted that due to inoculation of Fluid Viscous Dampers (FVD) in the structures the displacements have been reduced by 89.91% for corner damping, 86.50% for alternate damping, 88.34% for central damping ...

7

Seismic   Response of Primary Circuit with Viscous Dampers (K328)

Seismic Response of Primary Circuit with Viscous Dampers (K328)

... GERB viscous damper ...of viscous dampers are frequency-dependent, new approach for calculation of eigenfrequencies and seismic response was ...

8

Application of Fluid Viscous Dampers In Multi-Story Buildings

Application of Fluid Viscous Dampers In Multi-Story Buildings

... 1. Viscous Dampers will work and induce damping only if the two points it connects have significant relative ...movement. Viscous damper can be installed in structures in different configuration to ...

6

Seismic Study of Multi Storey Structure with Fluid Viscous Dampers using Etabs

Seismic Study of Multi Storey Structure with Fluid Viscous Dampers using Etabs

... This Paper concentrates on the seismic performance of the RC structure furnished using and deprived of Fluid Viscous dampers. This Paper is prepared to find declination in responses of earthquake in the ...

6

Effect of Viscous Dampers on Response Reduction Factor for RCC Frame using Response Spectrum Analysis

Effect of Viscous Dampers on Response Reduction Factor for RCC Frame using Response Spectrum Analysis

... as viscous dampers. Viscous dampers functions on the principle of passive energy dissipation by adding damping of seismic forces in the ...with viscous damper shows that it can reduce ...

6

Reliability-based optimal design of nonlinear viscous dampers for the seismic protection of structural systems

Reliability-based optimal design of nonlinear viscous dampers for the seismic protection of structural systems

... nonlinear viscous dampers by developing response hazard curves for values between ...with dampers, or the costs associated to it (Taflanidis and Beck 2009; Gidaris and Taflanidis ...

20

MID Column Pounding Effects on Adjacent Tall Buildings and its Mitigation using Viscous Dampers

MID Column Pounding Effects on Adjacent Tall Buildings and its Mitigation using Viscous Dampers

... [19] V. Sadeghi Balkanloua et.al (2013), “ Evaluating Effects of Viscous Dampers on optimizing Seismic Behavior of Structures “ , International Journal of Current Engineering and Technology, Vol.3, No.4 ...

6

Effect of the damper property variability on the seismic reliability of linear systems equipped with viscous dampers

Effect of the damper property variability on the seismic reliability of linear systems equipped with viscous dampers

... particular, viscous dampers have proved to be very efficient devices for dissipating the seismic input energy into heat, by reducing the displacement and inter-storey drift demand in structures (Lavan an ...

25

Assessment of optimal design methods of viscous dampers

Assessment of optimal design methods of viscous dampers

... The results obtained by considering the design method employing linear fitting for the response assessment are reported in the figure 4 for the cases corresponding to α = 0.3,0.6 and 1. In this case it can be seen that ...

6

Seismic Response Study of Multistoried Reinforced Concrete Building with Fluid Viscous Dampers

Seismic Response Study of Multistoried Reinforced Concrete Building with Fluid Viscous Dampers

... of Dampers for Vibration Control of Structures: An overview” has briefly explained that Viscous dampers works based on fluid flow through ...orifices. Viscous damper is as shown in ...

5

Assessment of optimal design methods of viscous dampers

Assessment of optimal design methods of viscous dampers

... Two approximate methodologies for the optimal design of viscous dampers have been presented in this study. The approaches allow controlling the maximum inter-storey drift by reducing at the same time the ...

6

Adaptation of High Viscous Dampers (HVD) for Essential Decreasing of In-Structure Floor Response Spectra

Adaptation of High Viscous Dampers (HVD) for Essential Decreasing of In-Structure Floor Response Spectra

... VD dampers installation to connect the buildings is shown in ...where dampers are attached to the ...the dampers attachment to the walls of the building. Indeed the dampers connection has to ...

12

3-D Base Control Systems for the Seismic Protection of Power Plant Equipment and Buildings

3-D Base Control Systems for the Seismic Protection of Power Plant Equipment and Buildings

... Reactor buildings, nuclear islands and similar seismic category 1 equipment-structures in nuclear facilities can be protected utilizing carefully applied principles. This offering presents some earthquake control ...

8

A Review on Seismic Analysis of Buildings using Passive Energy Dissipating Devices

A Review on Seismic Analysis of Buildings using Passive Energy Dissipating Devices

... generally RC frames with masonry infill. These structures have very little resistance for lateral masses caused by earthquake and wind. Even for adequately designed structures conjointly, because of permissible ...

7

Supporting brace sizing in structures with added linear viscous fluid dampers: A filter design solution

Supporting brace sizing in structures with added linear viscous fluid dampers: A filter design solution

... multiple dampers are ...the viscous dampers are sized in the normal way – using an optimal design methodology that ignores the dynamic effects of supporting brace ...

16

Show all 1250 documents...

Related subjects