• No results found

chilled water

An adaptive neural network controller for chilled water temperature in HVAC systems

An adaptive neural network controller for chilled water temperature in HVAC systems

... a chilled water loop. Both the compressor and chilled water pump are equipped with variable speed drivers so that the flow rate variables in either loop can be adjusted continuously to satisfy ...

5

Study on turbine inlet air cooling by 
		chilled water from steam absorption chiller

Study on turbine inlet air cooling by chilled water from steam absorption chiller

... produce chilled water in double effect lithium bromide absorption ...The chilled water is passed through a heat exchanger to cool the ambient air ...

5

Performance And Energy Analysis For Hybrid Evaporative Chiller System Controlled By Chilled Water Temperature By Heater

Performance And Energy Analysis For Hybrid Evaporative Chiller System Controlled By Chilled Water Temperature By Heater

... and water cooled chiller ...The chilled water temperature is one of the factor that affected the coefficient of performance and the power consumption of the conventional chiller ...in chilled ...

24

Chilled Water Pump trouble shooting by A  
		I : A case study

Chilled Water Pump trouble shooting by A I : A case study

... HVAC chilled water pump (Various Global Chilled Water Pump Manufacturers: Grundfos, KSB, Armstrong, Kirloskar ...the Chilled Water Pump trouble ...(ANN)in chilled ...

7

Study on the Elman Neural Network Operation Control Strategy of the Central Air Conditioning Chilled Water System*

Study on the Elman Neural Network Operation Control Strategy of the Central Air Conditioning Chilled Water System*

... of chilled water piping system, resulting in the chilled water system flow changes in the system under a certain load, the inevitable change of chilled water supply and return ...

10

Experimental and Numerical Study of Heat Transfer Process of Chilled Water Storage Tank

Experimental and Numerical Study of Heat Transfer Process of Chilled Water Storage Tank

... rectangular chilled water tank equipped with several different inlet diffusers during charging cycle, diffuser parameters including pipe size, hole size, number of opening, hole shape, spacing and inlet ...

13

Design, Manufacturing of Chilled Water System for Process Cooling Application

Design, Manufacturing of Chilled Water System for Process Cooling Application

... A chiller is a machine that removes heat from a liquid via a vapour-compression or absorption refrigeration cycle. This liquid can then be circulated through a heat exchanger to cool air or equipment as required. Vapour ...

7

Experimental study of a gas engine driven heat pump system for space heating and cooling

Experimental study of a gas engine driven heat pump system for space heating and cooling

... the chilled water flow rate on the performance of the GEHP ...the chilled water flow rate increases, the cooling capacity increases remarkably while the gas energy does not show a significant ...

14

Effect of irreversibility on COP of double effect steam absorption 
		chillers

Effect of irreversibility on COP of double effect steam absorption chillers

... Studies on absorption chillers performances have been published by many authors. Gamri [3] investigated the potential of single effect, double effect and multiple effect absorption cycles for chilled water ...

5

Options for cost-effective and efficient use of piggery biogas energy Project 4C-116

Options for cost-effective and efficient use of piggery biogas energy Project 4C-116

... into chilled water for use in mechanical air cooling and producing chilled drinking water; however, pricing and technical information was difficult to obtain for micro absorption chillers in ...

141

INTERNATIONALJ OURNAL OF ENGINEERINGS CIENCES & MANAGEMENT DESIGN OF HVAC SYSTEM FOR A COMMERCIAL BUILDING BY USING RADIANT COOLING Mohammed Yaseen Ahmed 1Asst Prof, Siripragada Bharghavi2 Asst Prof, Md Javeed Ali Khan 3 Asst Prof & Shaik Azmath 4Asst Pro

INTERNATIONALJ OURNAL OF ENGINEERINGS CIENCES & MANAGEMENT DESIGN OF HVAC SYSTEM FOR A COMMERCIAL BUILDING BY USING RADIANT COOLING Mohammed Yaseen Ahmed 1Asst Prof, Siripragada Bharghavi2 Asst Prof, Md Javeed Ali Khan 3 Asst Prof & Shaik Azmath 4Asst Prof, Mechanical Dept

... our designing will make sure in this we are using a temperature controlled surface that cool cools indoor temperature by removing sensible heat and where the half of the heat transfer occur through thermal radiation i . ...

23

Thermal Energy Storage:Analysis and Application

Thermal Energy Storage:Analysis and Application

... A chilled water system is a better alternative to a direct expansion system when cooling capacity needed is very high, especially in manufacturing ...The chilled water system can replace ...

105

A Comparison of Methods to Verify Energy Saving Benefits for Chillers

A Comparison of Methods to Verify Energy Saving Benefits for Chillers

... of chilled water, supply and return tempera- ture of cooling water, chilled water flow and the power dissipation of the chiller on the site were used to estab- lish the energy ...

6

Energy Generation from Peltier Module by Utilizing Heat

Energy Generation from Peltier Module by Utilizing Heat

... cooling to the opposite sides of Peltier module. Waste heat, woods or candle fumes can be used as the heating source and chilled water, ice or nitrous oxide can be used as the cooling source. It works on ...

5

Basic Classification of HVAC Systems for Selection Guide

Basic Classification of HVAC Systems for Selection Guide

... Normally terminal unit like FCU keeps on cooling the room air again and again with the help of cooling coil circulating chilled water. Therefore sensible cooling load is handled by water system. ...

10

A Combined District Heating and Cooling Network in City of Gera (Germany) using Steam-Jet Ejector Technology

A Combined District Heating and Cooling Network in City of Gera (Germany) using Steam-Jet Ejector Technology

... the chilled- water supply occured. The chilled-water demand corresponds to the expectations, especially concerning the year-round base demand for chilled water ...the ...

8

Mechanical Properties and Microstructures of Locally Produced Aluminium Bronze Alloy

Mechanical Properties and Microstructures of Locally Produced Aluminium Bronze Alloy

... furnace. The normalising (heating to 250˚C and cooling in air) and ageing (heating to 160˚C and 180˚C, held for 6 hours and then cooled in water at room temperature) were done on prior annealed and solution heat ...

7

Performance Assessment of Large Vapor Absorption System

Performance Assessment of Large Vapor Absorption System

... chiller, water is the refrigerant, and aqueous lithium bromide (Li-Br) is the ...source, water as refrigerant, lithium bromide as absorbent and produces the chilled water under vacuum ...

10

Synthesis of some novel thiazole derivatives

Synthesis of some novel thiazole derivatives

... with chilled water (50 mL), the obtained solid was filtered dried under vacuum at 45-50°C to get 2b as yellow ...to chilled water (100 mL), the obtained precipitated solid was filtered and ...

6

Power Usage Effectiveness analysis and optimization in the INFN CNAF Tier-1 data center infrastructure

Power Usage Effectiveness analysis and optimization in the INFN CNAF Tier-1 data center infrastructure

... the water pumps and related piping system) and the power room with all the power switches and electrical measurement instruments and ...to water” heat exchanger. The cold water is provided by the six ...

8

Show all 10000 documents...

Related subjects