• No results found

drift tube ion mobility

Studies of ion transport properties and ion molecule interactions in a drift tube mass spectrometer

Studies of ion transport properties and ion molecule interactions in a drift tube mass spectrometer

... i Mobility An electric field E acting on a swarm of ions in a neutral buffer gas will cause them to acquire an average drift velocity vd in the direction of the field... constant of prop[r] ...

143

Using Ion Mobility Spectrometry to Study Protein Conformations in the Gas Phase

Using Ion Mobility Spectrometry to Study Protein Conformations in the Gas Phase

... to ion radial diffusion beyond the extreme diameter of sampling ...the drift cell. This drawback can be effectively overcome by applying an ion trap before injecting ions into the drift ...

112

Determination of Aflatoxins G1 and G2 Using Ion Mobility Spectrometry

Determination of Aflatoxins G1 and G2 Using Ion Mobility Spectrometry

... The mobility of an ion is determined by the ion velocity that is measured in the drift tube of the spectrometer where an electric filed is ...their drift, ions are separated ...

6

Laboratory Detection of Plastics in Seedcotton with Ion Mobility Spectrometry

Laboratory Detection of Plastics in Seedcotton with Ion Mobility Spectrometry

... ions. Ion clusters enter the drift tube through the shutter and move toward the detector plate under the influence of an electric ...the drift tube by clean dry ...against drift ...

9

Field asymmetric ion mobility spectrometry based plant disease detection : intelligent systems approach

Field asymmetric ion mobility spectrometry based plant disease detection : intelligent systems approach

... drifting tube and detection ...drifting tube, purified drift gas flows from the detection plate to the drafting tube entrance and a homogeneous electric field, which is generated by a series ...

16

Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing

Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing

... of drift tube loaded with a DC or AC voltage, the height of the ion beam entering into the drift tube is narrowed, lead- ing to a decrease of FWHM and improvement of the ...

12

1.
													Embedded linux based data acquisition system for ion mobility spectrometer

1. Embedded linux based data acquisition system for ion mobility spectrometer

... the drift tube for 30 ...data, drift time is computed. Drift time taken by the sample is compared with the available library data and the graph is plotted on touch screen LCD with peak ...

6

Editorial and Review: 30th ASMS Sanibel Conference on Mass Spectrometry-Computational Modelling in Mass Spectrometry and Ion Mobility: Methods for Ion Structure and Reactivity Determination

Editorial and Review: 30th ASMS Sanibel Conference on Mass Spectrometry-Computational Modelling in Mass Spectrometry and Ion Mobility: Methods for Ion Structure and Reactivity Determination

... The second session on Friday, Small Molecule and Peptide Molecular Dynamics and Quantum Mechanics, focused on applications of theory in diverse areas. Bela Paizs (Bangor University, UK) presented data from a cyclic ...

8

Ion mobility mass spectrometry reveals conformational flexibility in the deubiquitinating enzyme USP5

Ion mobility mass spectrometry reveals conformational flexibility in the deubiquitinating enzyme USP5

... Ion mobility spectrometry (IMS) linked to MS (IM-MS) is a powerful analytical and structural ...static drift-tube IMS cell or a travelling wave IMS (TWIMS) cell has the added advantage that it ...

20

Molecular characterization of alkyl nitrates in atmospheric aerosols by ion mobility mass spectrometry

Molecular characterization of alkyl nitrates in atmospheric aerosols by ion mobility mass spectrometry

... stable ion adducts while minimizing the corona discharge was found to be − 1800 ...the drift tube through a Bradbury–Nielson (BN) ion gate located at the entrance with the assistance of 1 L ...

11

Development of Linearized Collision Operator for Multiple Ion Species in Gyrokinetic Flux-Tube Simulations

Development of Linearized Collision Operator for Multiple Ion Species in Gyrokinetic Flux-Tube Simulations

... tiple ion species plasmas were constructed, which satis- fies not only the conservation laws for particle, momen- tum, and energy, but also the adjointness relations and the Boltzmann’s ...

9

A selected ion flow tube study of some gas phase ion molecule reactions of potential relevance to the chemistry of dense interstellar clouds

A selected ion flow tube study of some gas phase ion molecule reactions of potential relevance to the chemistry of dense interstellar clouds

... A SELECTED-ION FLOW TuBE STUDY OF SOME GAS-PHASE ION-MOLECULE REACTIONS OF POTENTIAL RELEVANCE TO THE CHEMISTRY OF DENSE INTERSTELLAR CLOUDS... A thesis presented for the Degree of Docto[r] ...

394

Drift Mobility, Diffusion Coefficient of Randomly Moving Charge Carriers in Metals and Other Materials with Degenerated Electron Gas

Drift Mobility, Diffusion Coefficient of Randomly Moving Charge Carriers in Metals and Other Materials with Degenerated Electron Gas

... that drift mobility of randomly moving charge carriers, depending on the degree degeneracy, can considerably exceed the Hall ...the drift mobility of charge carriers is valid even in the case ...

9

Learning in the presence of sudden concept drift and measurement drift

Learning in the presence of sudden concept drift and measurement drift

... When applied to the attribute space, the concept drift algorithms transfer simply into the measurement drift problem. The window size is selected in the same way as it was in the classification problems ...

79

The role of ion fluxes in polarized cell growth and morphogenesis: the pollen tube as an experimental paradigm

The role of ion fluxes in polarized cell growth and morphogenesis: the pollen tube as an experimental paradigm

... of ion transporter systems is a key point to address both of these questions, because to date all fluxes, intracellular free concentration, and sub-cellular local- ization of transporters were shown to be ...

14

Measurement of ion mobility in dielectric liquids Master of Science Thesis in Electric Power Engineering

Measurement of ion mobility in dielectric liquids Master of Science Thesis in Electric Power Engineering

... Ion mobility in insulation oil has an effect on the dynamics of an electric field distribution in oil ...negative ion mobility helps to improve accuracy in the simulation of electric field ...

71

Engl, Albert
  

(2011):


	Precise muon drift tube detectors for high background conditions.


Dissertation, LMU München: Fakultät für Physik

Engl, Albert (2011): Precise muon drift tube detectors for high background conditions. Dissertation, LMU München: Fakultät für Physik

... maximum drift time by a factor 4 to a value of 180 ...the tube to ...mm drift tube detectors are therefore reasonable candidates for precise and efficient muon track reconstruction in high ...

97

Gas phase stability of Protein Ions in a Cyclic Ion Mobility Spectrometry Traveling Wave Device

Gas phase stability of Protein Ions in a Cyclic Ion Mobility Spectrometry Traveling Wave Device

... of ion heating during the T-Wave based IM separation (Figure ...a mobility-selected ion population can be collected in the pre-store while the remaining ions are removed from the ...

33

Computational Methods for Metabolomic Data Analysis of Ion Mobility Spectrometry Data—Reviewing the State of the Art

Computational Methods for Metabolomic Data Analysis of Ion Mobility Spectrometry Data—Reviewing the State of the Art

... the drift region when the ion shutter is open (Figure ...so-called drift gas will flow from the Faraday-Plate towards the ions; neutral molecules cannot enter the drift region and the ionized ...

23

Show all 9421 documents...

Related subjects