Analysis of Fault Detection and its Location using Microcontroller for Underground Cables

Analysis of Fault Detection and its Location using Microcontroller for Underground Cables

... to underground conditions, wear and tear, rodents etc. Also detecting fault source is difficult and entire line is to be dug in order to check entire line and fix ...cable fault detection over ...

6

Fault Location and Incipient Fault Detection in Distribution Cables

Fault Location and Incipient Fault Detection in Distribution Cables

... The fault location in underground cables is characterized as the technical difficulties due to the complexities in ...(XLPE) cables rated at the medium voltage ...the fault distance and ...

266

Underground Cable Fault Detection and Transmission of Intimation through Soil Wireless Transceiver

Underground Cable Fault Detection and Transmission of Intimation through Soil Wireless Transceiver

... The computer is attached to the WUSN using serial converter displays the live information about the underground cables in a spreadsheet which is coded with c programming language. In the flow chart ‘n’ ...

5

UNDERGROUND CABLE FAULT DETECTION USING IOT

UNDERGROUND CABLE FAULT DETECTION USING IOT

... lines, underground cables have been used for many decades. Underground high voltage cables are used more and more because they are not influenced by weather conditions, heavy rain, storm, snow ...

10

GSM based Underground Cable Fault Detection

GSM based Underground Cable Fault Detection

... calculate fault distance by impedence matching having local voltage and current as input ...impedance-based fault location formulation for single line-to-ground faults by using only local voltages and ...

5

Underground Cable Fault Detection Using Matlab

Underground Cable Fault Detection Using Matlab

... The power delivering to consumer should be with less losses and safe medium. Overhead transmission lines are being used in current power system which is not much reliable or safe so to overcome its problem ...

6

Localization of Faults in 11KV/220KV/400KV Underground Cables by Wavelet Transform

Localization of Faults in 11KV/220KV/400KV Underground Cables by Wavelet Transform

... with fault appearance in underground cable where they employed the wavelet transform to extract high frequency components superimposed on fault signals simulated using ...for fault ...

11

Detection of Underground Cable Fault using Arduino

Detection of Underground Cable Fault using Arduino

... in underground cables.But unlike underground cables the overhead cables have the drawback of being easily prone to the effects of ...requires cables with reliability,increased ...

5

Capacitance of Water Tree Modeling in Underground Cables

Capacitance of Water Tree Modeling in Underground Cables

... higher fault impedance than typical high impedance faults. Since detection techniques rely on ob- serving a response from the fault itself, high impedance significantly reduces the magnitude of the ...

11

Monitoring and Detection of Voltage Stress in Underground Cables Using I2C Protocol

Monitoring and Detection of Voltage Stress in Underground Cables Using I2C Protocol

... power cables have been identified through I2C protocol. Where ever the fault possibilities identified by the voltage stress sensor and it is immediately sent to the corresponding authority by two wire ...

8

Underground Cable Fault Distance Detector using ATmega328 Microcontroller

Underground Cable Fault Distance Detector using ATmega328 Microcontroller

... Frequent fault in underground cables due to the breakdown of paper plastic insulation due to chemical reaction or poor workmanship during installation and the difficulties in locating the approximate ...

9

UNDERGROUND CABLE FAULT DISTANCE DETECTOR USING ATMEGA328 MICROCONTROLLER

UNDERGROUND CABLE FAULT DISTANCE DETECTOR USING ATMEGA328 MICROCONTROLLER

... an underground cable which can accurately spot the fault point and can report the coordinates of the fault point, which is novel attempt by using a GPS ...the fault exists in the cables ...

8

UNDERGROUND CABLE FAULT USING ROBOT

UNDERGROUND CABLE FAULT USING ROBOT

... the cables are dug out from location and checked manually to find exact point of ...of cables leads to economic losses, which can be avoided by replacing decision based on the specific site data rather than ...

7

Technical consideration and impact of converting overhead power lines to underground power cables

Technical consideration and impact of converting overhead power lines to underground power cables

... XLPE cable is the major developing technology and has wide industry acceptance at voltages up to 132-154kV. This type of cable uses vulcanised polyethylene insulation, which is solid insulation extruded onto the ...

350

Company Directive STANDARD TECHNIQUE : CA6A/3. Relating to the Installation of Underground Cables

Company Directive STANDARD TECHNIQUE : CA6A/3. Relating to the Installation of Underground Cables

... core cables, the method to be adopted depends on site ...the cables are to be laid in a green-field site, it may prove preferable to pull the three cores simultaneously from three drums and then tie them ...

61

Analysis of Underground Cable Fault Distance Locator

Analysis of Underground Cable Fault Distance Locator

... circuit fault in the underground cable from feeder end in km by using ...so fault can be easily detected and ...any fault like short circuit occurs, voltage drop will vary depending on the ...

6

TRAIN DETECTION BONDING AND CABLES

TRAIN DETECTION BONDING AND CABLES

... Jumper cables are provided to maintain continuity of track circuits through points, crossings and across polarity changing ...jumper cables are connected to the positions shown on the bonding ...jumper ...

17

Hot spot removal of underground E. H. V. cables by evaporative cooling.

Hot spot removal of underground E. H. V. cables by evaporative cooling.

... 7.5‘‘diameter cables with sane burial depth, side to side cable spacing and separation between cooling sheath and cables as for the 5 " diameter cables done ...

96

IOT based underground cable fault detector

IOT based underground cable fault detector

... Underground cables are prone to a wide variety of faults due to underground conditions, wear and tear, rodents ...the fault source is difficult and entire cable should be taken out from the ...

5

Investigate the use of thermal protection for underground cables in Ergon Engery's electricity network

Investigate the use of thermal protection for underground cables in Ergon Engery's electricity network

... of cables, the issues and the effects have on cables was far more intensive than originally ...of cables and the installation of these ...of cables using the earthing of sheaths, the thermal ...

90