• No results found

gait symmetry

Evaluation of gait symmetry in poliomyelitis subjects : Comparison of a conventional knee ankle foot orthosis (KAFO) and a new powered KAFO

Evaluation of gait symmetry in poliomyelitis subjects : Comparison of a conventional knee ankle foot orthosis (KAFO) and a new powered KAFO

... Slow walking speeds, reduced cadence, long stride times, plus long stance and double limb support duration, with short swing and single support durations, plus short step lengths are the main characters of walking with ...

9

Combined effects of age and gender on gait symmetry and regularity assessed by autocorrelation of trunk acceleration

Combined effects of age and gender on gait symmetry and regularity assessed by autocorrelation of trunk acceleration

... Regarding gait indices of anteroposterior acceleration, elderly participants of this study showed approximate values of ...for symmetry index and 0.84 - 0.88 for regularity index (see Table 2). Gait ...

6

Recommended number of strides for automatic assessment of gait symmetry and regularity in above-knee amputees by means of accelerometry and autocorrelation analysis

Recommended number of strides for automatic assessment of gait symmetry and regularity in above-knee amputees by means of accelerometry and autocorrelation analysis

... virtual gait trainer ” would be very useful, ...of gait in terms of symmetry and regularity and that can provide indications for improving the ...text, gait symmetry is the degree of ...

8

Improvement of walking speed and gait symmetry in older patients after hip arthroplasty: a prospective cohort study

Improvement of walking speed and gait symmetry in older patients after hip arthroplasty: a prospective cohort study

... in gait patterns ...evaluate symmetry in gait ...and symmetry index for male and female patients with THA did not reach the values of the refer- ence group even after an intensive ...

8

Gait symmetry and regularity in transfemoral amputees assessed by trunk accelerations

Gait symmetry and regularity in transfemoral amputees assessed by trunk accelerations

... of gait symmetry and regularity in sub- jects wearing lower limb prostheses has been performed in previous ...asymmetrical gait compared to control subjects, and the amount of asym- metry was related ...

10

How innate is locomotion in precocial animals? A study on the early development of spatio temporal gait variables and gait symmetry in piglets

How innate is locomotion in precocial animals? A study on the early development of spatio temporal gait variables and gait symmetry in piglets

... studying gait development in neonatal pigs through the analysis of spatio-temporal gait characteristics during locomotion at self-selected ...the gait pattern, left – right asymmetry was ...

11

A perceptual map for gait symmetry quantification and pathology detection

A perceptual map for gait symmetry quantification and pathology detection

... atypical gait can be caused by different factors, either orthopedic (hip injuries [4], bone malformations, ...make gait analysis a complex procedure but also a reliable and accurate indicator for early ...

24

Functional electrical stimulation following anterior cruciate ligament reconstruction: a randomized controlled pilot study

Functional electrical stimulation following anterior cruciate ligament reconstruction: a randomized controlled pilot study

... Descriptive statistics was used to report the feasibility outcomes (e.g., ability to use FES in the first postopera- tive week), as well as participants’ baseline characteris- tics. The Shapiro-Wilk test was used to test ...

9

The role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review

The role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review

... cycle, gait velocity, step length, and cadence were measured in two of the four studies [21, ...23]. Gait cycle was defined as the time between initial contact of one foot with the ground and contact of the ...

9

Temporal symmetry of sound and prosthetic limbs during transtibial amputee gait with various prosthetic alignment

Temporal symmetry of sound and prosthetic limbs during transtibial amputee gait with various prosthetic alignment

... the gait cycle in subjects with transtibial amputation (Bateni & Olney, 2002; Thomas et ...of gait symmetry between a transtibial amputee and groups of healthy persons (Winter & Sienko, 1988; ...

6

Impact on gait biomechanics of using an active variable impedance prosthetic knee

Impact on gait biomechanics of using an active variable impedance prosthetic knee

... marked gait asymmetry and with increased upper body involvement compared to able-bodied ...these gait changes can lead to chronic hip and lower back pain and ...improved gait over older devices and ...

11

Relearning functional and symmetric walking after stroke using a wearable device: a feasibility study

Relearning functional and symmetric walking after stroke using a wearable device: a feasibility study

... largest gait velocity improve- ...no gait symmetry improvements, especially step length symme- try, in approximately 40% of participants [37, ...

8

Visual cue training to improve walking and turning after stroke: a study protocol for a multi centre, single blind randomised pilot trial

Visual cue training to improve walking and turning after stroke: a study protocol for a multi centre, single blind randomised pilot trial

... The randomisation will be created using StataSEv9 (StataCorp, College Station, TX, USA) statistical software with a 1:1:1 allocation using random permuted blocks of varying size (for unpredictable allocation sequence ...

24

Distinct feature extraction for video-based gait phase classification

Distinct feature extraction for video-based gait phase classification

... 9 gait events, we first manually identify all frames that separate adjacent gait phases by finding specified gait poses defined in ...interpolated gait parameters (see Table I). Finally, we ...

13

Reference values for gait temporal and loading symmetry of lower-limb amputees can help in refocusing rehabilitation targets

Reference values for gait temporal and loading symmetry of lower-limb amputees can help in refocusing rehabilitation targets

... The SNS median for TFC (1.11) compares well with the median SNS that can be calculated from the results reported in [3] (1.09). Furthermore, our results can be compared with the study of Nolan et al. [2], that involved 4 ...

12

Scattering formula for the topological quantum number of a disordered multimode wire

Scattering formula for the topological quantum number of a disordered multimode wire

... chiral symmetry to all five topologically nontrivial symmetry ...superconducting symmetry classes, while they reinforce each other in the chiral symmetry ...

8

The Relationship between Gait Kinetics and Normalized Gait Kinematics

The Relationship between Gait Kinetics and Normalized Gait Kinematics

... Lastly, gait data were collected by The Electronic Caregiver ...describing gait biomechanics were collected at ...history, gait trial data, and leg ...

9

Group Theory and Symmetry The study of symmetry has undergone tremendous changes in late 19

Group Theory and Symmetry The study of symmetry has undergone tremendous changes in late 19

... and Symmetry- The study of symmetry has undergone tremendous changes in late 19 th and earlier 20 th centuries with the development of group theory, Group theory has found applications in geometry, graph ...

7

Abnormal gait classification using silhouettes

Abnormal gait classification using silhouettes

... and the necessity about the experiments were explained to individual person who have taken into experiments. All are of male candidates. During experiments subjects were wearing different types of clothes like pant, ...

5

Automatic gait recognition by symmetry analysis

Automatic gait recognition by symmetry analysis

... To investigate the effects of noise, we added synthetic noise to each image frame of a test sub- ject and compared the resulting signature with those of the other subjects in the database. Fig. 6e and f shows samples of ...

9

Show all 3040 documents...

Related subjects