• No results found

generator excitation

An Exact Method to Compute Time Delay Margin for Stability of Time- Delayed Generator Excitation Control System

An Exact Method to Compute Time Delay Margin for Stability of Time- Delayed Generator Excitation Control System

... a generator excitation control system compensated with a stabilizing transformer known as rate feedback stabilizer to damp out ...the excitation control system becomes unstable when the time delay ...

8

Stability Analysis of Time Delayed Generator Excitation Control System using Resultant Theory

Stability Analysis of Time Delayed Generator Excitation Control System using Resultant Theory

... Time Delays have become unavoidable in Power System due to the usage of measurement devices and communication links for transferring the control signals. This paper investigates the effect of time delays on the stability ...

6

Enhancing Angular Stability in Multi-Machine Power System with using a New Control Method

Enhancing Angular Stability in Multi-Machine Power System with using a New Control Method

... A generator excitation predictive control scheme is introduced in [6], ...of excitation system and imposes extra ...adding generator excitation ...

7

Robust power system stabilizer design based on LMI optimization approach

Robust power system stabilizer design based on LMI optimization approach

... In order to analyze the suitability of the LMI theory for generator excitation systems, the design of a LMI optimization based power system stabilizer will be investigated in this thesis[r] ...

24

A Robust Decentralized Sliding-Mode Control for a SMIB-SVC System

A Robust Decentralized Sliding-Mode Control for a SMIB-SVC System

... The generator excitation and the SVC regulator controllers consider the uncertainties of the nonlinear structure and the interconnection between subsystems as perturbations, requiring only local ...

25

The User defined Modeling Method of Power System Components Based on RTDS CBuilder

The User defined Modeling Method of Power System Components Based on RTDS CBuilder

... the excitation system are to provide the excitation source for the generator, stabilize the terminal voltage, demagnetize when the generator shed the load, rapidly and forcibly excite in the ...

7

Coordinated FACTS & Fuzzy Logic based WADC for Small Signal Stability Enhancement of Multi-machine P
                 

Coordinated FACTS & Fuzzy Logic based WADC for Small Signal Stability Enhancement of Multi-machine P  

... Power system nowadays is a complex network, sometimes made of thousands of buses and hundreds of generators. Available power generation usually does not situated near anuprising of load center. In order to meet the ...

6

Verification Platform for Plant AVC Substations based on Digital Simulation Technology

Verification Platform for Plant AVC Substations based on Digital Simulation Technology

... After the AVC master station sends control instructions to the detected substation device, the AVC substation can obtain the power plant model from the simulated power system and collect the current grid data for ...

11

Fuzzy logic controller for  synchronous generators in a stand alone multi machine power system

Fuzzy logic controller for  synchronous generators in a stand alone multi machine power system

... Abstract— This paper will deal with the design and development of fuzzy logic based controller implemented in synchronous generator excitation system that serves in isolated multi-machine power system. The ...

8

A Full Dynamic Voltage Stability Research Based on Time domain Simulation

A Full Dynamic Voltage Stability Research Based on Time domain Simulation

... Generator excitation system’s condition and its limiter are important factors that influence system voltage sta- ...bility. Excitation regulator is the main method of voltage control in power system, ...

5

Different Self Excitation Techniques for Slip Ring Self Excited Induction Generator

Different Self Excitation Techniques for Slip Ring Self Excited Induction Generator

... The different schemes to self excite the wound rotor induction machine are presented. Scheme in section 2.4 is the simplest and can provide wide range of voltage and frequency, for constant excitation capacitor. ...

8

“Stability Criterion of a Processing Plant using PID Controller”

“Stability Criterion of a Processing Plant using PID Controller”

... Depending on the communication link is used, to analysis the communication delays is considered to be in the range of 80-600 milliseconds. In power system control, the total measurement of delay is taken in the order of ...

5

Simulink Modelling of Current Control of Induction Generator by Using Hybrid Active Filter in Wind Energy System

Simulink Modelling of Current Control of Induction Generator by Using Hybrid Active Filter in Wind Energy System

... induction generator and is transmitted to the grid by the stator ...the generator output power to its nominal value for high wind ...induction generator speed must be slightly above the synchronous ...

8

Steady State Analysis of an Isolated Self Excited Dual Three Phase Induction Generator for Renewable Energy

Steady State Analysis of an Isolated Self Excited Dual Three Phase Induction Generator for Renewable Energy

... The two star-capacitor SE-DTPIG needs a minimum value of capacitance to self-excites at no-load. The no-load terminal voltage can be computed for different value of star-capacitances using a computer algorithm for ...

9

Simulink modelling and simulation for self excited doubly salient retarder system

Simulink modelling and simulation for self excited doubly salient retarder system

... the excitation current, so that the brake is more compliant and comfortable, and will have extensive market ...Self- excitation doubly salient retarder braking model by ...retarder excitation current ...

6

Parameter Estimation of Exciation Systems

Parameter Estimation of Exciation Systems

... In [7], parameter estimation was performed in frequency-domain. The author utilized FFT and complex curve fitting technique to estimate the parameters of a excitation system model, which is a model developed by ...

91

Callide C Power Station's generator protection system 'ride through capabilities' for various external faults

Callide C Power Station's generator protection system 'ride through capabilities' for various external faults

... Australia has the largest electrical network in the world by distance and it is the specified performance standards that entire system models and contingencies are based upon. Because of this importance, if there is an ...

119

Research on the Influence of Alternating Electromagnetic Field on Conductivity of Hard Water

Research on the Influence of Alternating Electromagnetic Field on Conductivity of Hard Water

... invariable excitation current, the higher output voltage was, the less the scale weight was on the water tube wall when the water hardness was 1000mg/L, 180 mg/L and 500 mg/L ...the excitation current of ...

14

Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

... induction generator. The proposed LOE detection strategy is based on the multiplication of both the DFIG terminal voltage derivative and the DFIG output reactive power derivative, and the proposed SPS detection ...

11

Equation Solution for the Current in Radial Impedance Monopole on the Perfectly Conducting Sphere

Equation Solution for the Current in Radial Impedance Monopole on the Perfectly Conducting Sphere

... of excitation of the monopole by the δ-generator of voltage, located on the finite distance over the spherical scatterer, and at the excitation of the monopole at its ...

20

Show all 4598 documents...

Related subjects