• No results found

global trigger

Characterisations of adverse events detected in a university hospital: a 4-year study using the Global Trigger Tool method

Characterisations of adverse events detected in a university hospital: a 4-year study using the Global Trigger Tool method

... Characterisations of adverse events detected in a university hospital: a 4-year study using the Global Trigger Tool method.. To view these files please visit the journal online (http://d[r] ...

6

Describing adverse events in medical inpatients using the Global Trigger Tool.

Describing adverse events in medical inpatients using the Global Trigger Tool.

... validated Global Trigger Tool from the Institute for Healthcare ...the Global Trig- ger Tool, we conducted a retrospective chart review of adult patients hospitalised in five medical wards at a uni- ...

11

IHI Global Trigger Tool and patient safety monitoring in Finnish hospitals : Current experiences and future trends

IHI Global Trigger Tool and patient safety monitoring in Finnish hospitals : Current experiences and future trends

... interventions. Trigger tools - means for performing focused medical records reviews either manually or automatically, are among the candidate technologies that can serve the aforementioned ...IHI Global ...

96

Adverse events in orthopedic care identified via the Global Trigger Tool in Sweden – implications on preventable prolonged hospitalizations

Adverse events in orthopedic care identified via the Global Trigger Tool in Sweden – implications on preventable prolonged hospitalizations

... Methods: We used national data from a structured two-stage record review with a Swedish modification of the Global Trigger Tool. The sample was 4,994 randomly selected orthopedic admissions in 56 hospitals ...

9

Uncertain added value of Global Trigger Tool for monitoring of patient safety in cancer care

Uncertain added value of Global Trigger Tool for monitoring of patient safety in cancer care

... The size of the two datasets does not allow for a robust comparison of events identified with GTT and DLCR, but the results suggest that the two methods are equally good at identifying specific surgical complications. ...

5

Measuring Adverse Events and Levels of Harm in Pediatric Inpatients With the Global Trigger Tool

Measuring Adverse Events and Levels of Harm in Pediatric Inpatients With the Global Trigger Tool

... Overall, the GTT proved useful in de- tecting a wide array of AEs, particularly events associated with the Medication and Cares modules. Despite having several adult-focused triggers and entire modules that captured no ...

11

Characterising the types of paediatric adverse events detected by the global trigger tool - CareTrack Kids

Characterising the types of paediatric adverse events detected by the global trigger tool - CareTrack Kids

... Third Global Patient Safety Challenge is Medication Without Harm, and our study has re-emphasised the frequency of occurrence of medication incidents in ...

23

Measurement of patient safety: a systematic review of the reliability and validity of adverse event detection with record review

Measurement of patient safety: a systematic review of the reliability and validity of adverse event detection with record review

... Design: A systematic review of the literature. Methods: We searched PubMed, EMBASE, CINAHL, PsycINFO and the Cochrane Library and from their inception through February 2015. We included all studies that aimed to describe ...

11

CMS trigger performance

CMS trigger performance

... L1 trigger has been through a major upgrade compared to Run 1, whereby all electronic boards of the system have been replaced, allowing more sophisticated algorithms to be run ...the global trigger, ...

14

Contribution of adverse events to death of hospitalised patients

Contribution of adverse events to death of hospitalised patients

... The aim of our study is to investigate the contribution of severe adverse events to death in hospitalised patients and clarify method- ological differences using the Global Trigger To[r] ...

8

The CMS trigger system

The CMS trigger system

... The DTTF processes the DTLT information in order to reconstruct muon track candidates measured in several concentric rings of detectors, called stations, and assigns a transverse momentum value to the track candidates ...

122

LUX trigger efficiency

LUX trigger efficiency

... two trigger groups with S2 filter outputs greater than the low filter threshold within a time window, called the trigger search window, which was set at 2 ...a trigger signal is sent to the DAQ and ...

32

KK-Matchgewehre Small Bore Target Rifles

KK-Matchgewehre Small Bore Target Rifles

... all times and especially when you are not present your rifle is well secured, out of any reach of children, careless adults and other unauthorised persons and in no way accessible to them. Never place any firearm in such ...

33

The ATLAS Muon Trigger

The ATLAS Muon Trigger

... muon trigger in Run 2 is designed as a two-stage system that consists of a hardware-based trigger system (Level 1 muon trigger) and a software-based reconstruction system (High Level muon ...muon ...

5

Refining Event Extraction through Cross Document Inference

Refining Event Extraction through Cross Document Inference

... We share the view of using global inference to improve event extraction with some recent re- search. Yangarber et al. (Yangarber and Jokipii, 2005; Yangarber, 2006; Yangarber et al., 2007) applied cross-document ...

9

The Design of the ZEUS regional first level trigger box and associated trigger studies

The Design of the ZEUS regional first level trigger box and associated trigger studies

... On a given wire, pulses arrive at different times at the two ends of the chamber depending on where along the wire the ionization was produced. Preamplifiers mounted on the chamber drive the signal along coaxial cable to ...

160

Search for K+ → π+νν̅ at NA62

Search for K+ → π+νν̅ at NA62

... A ring imaging cherenkov detector (RICH) identifies and timestamps the downstream tracks with better than 100 ps time resolution. The electromagnetic (LKr) and hadronic (MUV1,2) calorimeters refine the particle ...

10

Storytelling as a trigger for sharing conversations

Storytelling as a trigger for sharing conversations

... This article explores whether traditional oral storytelling can be used to provide insights into the way in which young people of 12-14 years identify and understand the language of emotion and behaviour. Following the ...

16

Word Association and MI Trigger based Language Modeling

Word Association and MI Trigger based Language Modeling

... It is found that proper MI-Trigger modeling is superior to word bigram model and the DD MI-Trigger models have better performance than the DI MI-Trigger models for the same window size..[r] ...

7

Evaluation path way of Schmitt Trigger with Leakage Reduction Techniques

Evaluation path way of Schmitt Trigger with Leakage Reduction Techniques

... The presented circuit is formed by a combination of one PMOS (P1) and three NMOS (N1, N2 and N3), there is no straight connection between supply voltage (Vdd) and ground (Vss) as PMOS is connected to power supply and ...

5

Show all 10000 documents...

Related subjects