• No results found

Glucose Measurement

Non Invasive Blood Glucose Measurement using NIR technique based on occlusion spectroscopy

Non Invasive Blood Glucose Measurement using NIR technique based on occlusion spectroscopy

... blood glucose monitoring techniques can be grouped as subcutaneous, dermal, epidermal and combined, dermal and epidermal measurements ...surface)glucose measurement techniques involve Near IR ...

9

SOFT CORE FPGA PLATFORM FOR BLOOD GLUCOSE MEASUREMENT

SOFT CORE FPGA PLATFORM FOR BLOOD GLUCOSE MEASUREMENT

... As NIR spectroscopy continues to be developed for blood glucose measurement, it is critical to assess model accuracy, precision and validation on the basis of clinically acceptable criteria. Multivariate ...

9

The Influence of Placement Time of Blood Samples on the Accuracy of Blood Glucose Measurement

The Influence of Placement Time of Blood Samples on the Accuracy of Blood Glucose Measurement

... blood glucose during the period when diabetes patients’ blood samples are collected through fasting blood and sent to the laboratory for detection on the accuracy on blood glucose ...blood glucose of ...

5

Noninvasive Blood Glucose Measurement Based on NIR Spectrums and Double ANN Analysis

Noninvasive Blood Glucose Measurement Based on NIR Spectrums and Double ANN Analysis

... ment has become a hot academic research topic (Ferrante do Amaral and Wolf 2008, Vashist 2012) [4] [5]. The researches of using near infrared spectroscopy for noninvasive blood glucose measurement are also ...

7

Continuous on line glucose measurement by microdialysis in a central vein  A pilot study

Continuous on line glucose measurement by microdialysis in a central vein A pilot study

... time measurement of glucose has emerged. Continuous glucose monitoring (CGM) can be potentially instrumental in pre- venting hypoglycaemia and a high glucose variability ...measuring ...

8

Accuracy Improvement of Blood Glucose Measurement System Using Quantum Cascade Lasers

Accuracy Improvement of Blood Glucose Measurement System Using Quantum Cascade Lasers

... blood glucose mea- surement systems based on QCLs; however, most of these systems use wave- length-tunable QCLs, which are expensive because a movable grating is re- ...of glucose [23] [24]. The authors ...

10

Non Invasive Glucose Measurement Techniques using Near Infrared Spectroscopy

Non Invasive Glucose Measurement Techniques using Near Infrared Spectroscopy

... of measurement and the calibration ...of measurement makes them vulnerable to low signal to noise ratio; which can be combated by considering a comprehensive evaluation of measurement which covers ...

7

Validity of over the counter finger stick glucose measurement devices in comparison with laboratory venous plasma glucose measurements on pregnant women with diabetes

Validity of over the counter finger stick glucose measurement devices in comparison with laboratory venous plasma glucose measurements on pregnant women with diabetes

... mean glucose values observed with glucometer readings can be due to the fact that post prandial capillary blood has higher glucose concentration than venous plasma values ...of glucose by glycolysis ...

6

Evaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method

Evaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method

... 5.Hossaini N, Safi S, Khansari MR, Sadeghpoor M, AsadiA. Comparison of the performance of two diagnostic kits (Elitech and Pars Azmoon) for measurement of glucose, creatinine, cholesterol and total ...

8

Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery

Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery

... subcutaneous glucose sensor, a battery-powered moni- tor, and a Com-Station for downloading stored data to a ...with glucose oxidase and covered with a semi- permeable ...Ambient glucose from ...

11

Clinical review: Consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adults

Clinical review: Consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adults

... continuous glucose monitoring systems? (Table 1) Continuous or automated intermittent glucose monitor- ing systems (CGMs) should safely and reliably provide an accurate interstitial fl uid or blood ...

13

A Study to Compare Arterial, Capillary and Venous Blood Glucose levels in Patients with Hypotension on Vasopressor versus Normotensive Patients

A Study to Compare Arterial, Capillary and Venous Blood Glucose levels in Patients with Hypotension on Vasopressor versus Normotensive Patients

... in glucose transit time and hence causing increased extraction of the glucose from the blood by the tissues, which in turn can give false ...blood glucose measurement by capillary method is ...

5

Noninvasive Blood Glucose Monitoring System Based on Distributed Multi Sensors Information Fusion of Multi Wavelength NIR

Noninvasive Blood Glucose Monitoring System Based on Distributed Multi Sensors Information Fusion of Multi Wavelength NIR

... blood glucose level control is very ...blood glucose level via an invasive finger-tip stick method, this way will inevitably bring patients pain and infection ...blood glucose measurement sys- ...

8

The effect of dietary methionine restriction and the mechanism of glucose and lipid metabolism in obese induced C57BL/6 Mice

The effect of dietary methionine restriction and the mechanism of glucose and lipid metabolism in obese induced C57BL/6 Mice

... Dissecting stage was prepared and the animals were anaesthetized with isoflurane, sacrificed by cervical dislocation and mice were placed in a supine position and immobilized. However, blood samples were collected from ...

23

On-chip Hematocrit Correction for Whole Blood Glucose Amperometric Sensing Strip Using a Post-Measurement Potential Step

On-chip Hematocrit Correction for Whole Blood Glucose Amperometric Sensing Strip Using a Post-Measurement Potential Step

... blood glucose meters are widely used in homes and hospitals due to its effectiveness, relative inexpensiveness, simplicity and convenience in ...blood glucose meters are easily interfered by inappropriate ...

10

Noninvasive Electromagnetic Wave Sensing of Glucose

Noninvasive Electromagnetic Wave Sensing of Glucose

... There are several kinds of interactions between light and biological tissues depending on the properties of target tissues and characteristics of illuminating light source. The interactions can be mainly categorized into ...

18

Nervous glucose sensing regulates postnatal β cell proliferation and glucose homeostasis

Nervous glucose sensing regulates postnatal β cell proliferation and glucose homeostasis

... Parasympathetic and sympathetic firing-rate recordings. Firing rate activi- ties were recorded at the level of the thoracic branch of the vagus nerve (parasympathetic) and the sympathetic trunk, along the carotid artery ...

13

Microfluidic Chip Integrated with an Electrolyte-Insulator-Semiconductor Sensor for pH and Glucose Level Measurement

Microfluidic Chip Integrated with an Electrolyte-Insulator-Semiconductor Sensor for pH and Glucose Level Measurement

... automatic measurement of sample solution. The pH level and glucose concentration are used to demonstrate the feasibility of the proposed ...method, glucose concentrations can be automatically ...

16

The Efficacy, Physiological Responses and Hematology of Persian Sturgeon, Acipenser persicus, to Clove Oil as an Anesthetic Agent

The Efficacy, Physiological Responses and Hematology of Persian Sturgeon, Acipenser persicus, to Clove Oil as an Anesthetic Agent

... and glucose level increase in this species or ...blood glucose and cortisol reach the level similar to the control group which was before applying clove ...

7

Optimization of a simple, accurate and low cost method for starch quantification in green microalgae

Optimization of a simple, accurate and low cost method for starch quantification in green microalgae

... starch measurement which is based on spectrophotometry at 540 nm absorp- ...the glucose assay. As shown in Table 2, the measurement accuracies of the additional corn starch (the internal controls) ...

6

Show all 10000 documents...

Related subjects