• No results found

IEC 61850

Monitoring and Controlling Services for Electrical Distribution Systems Based on the IEC 61850 Standard

Monitoring and Controlling Services for Electrical Distribution Systems Based on the IEC 61850 Standard

... International standards are being developed to promote rapid configuration and integration into the utility automation system. In order to take advantage of modern technology to provide new benefits to users of sub- ...

11

A Novel IEC 61850 Based Protection Scheme to Maintain the Generator
Synchronous Operation During Power System Disturbances

A Novel IEC 61850 Based Protection Scheme to Maintain the Generator Synchronous Operation During Power System Disturbances

... IEC 61850 GOOSE protocol: The IEC 61850 standard for substations enables the integration of all protection, control, measurement and monitoring ...

14

Standardization of power system protection settings using IEC 61850 for improved interoperability

Standardization of power system protection settings using IEC 61850 for improved interoperability

... Currently, IEC 61850 does not provide a full set of data objects which could describe all the technical specifications of relays from all ...the IEC 61850 data model, such as the lack of a ...

5

Dynamic Testing of an IEC 61850 Based  110 kV Smart Substation Solution

Dynamic Testing of an IEC 61850 Based 110 kV Smart Substation Solution

... An IEC 61850 based aotomation design, transitioning the conventional substation into a smart substation, where existing current/voltage transformers remain in service, and smart Field Apparatus Interface ...

10

Improving IEC 61850 interoperability and simplifying IED configuration through the standardisation of protection settings

Improving IEC 61850 interoperability and simplifying IED configuration through the standardisation of protection settings

... Second, manufacturers may prefer to use their own proprietary file formats and proprietary setting parameters, both for business strategy and to offer freedom to develop innovative functions without being constrained by ...

8

Fault Location, Isolation, and Service Restoration (FLISR) Technique using IEC 61850 GOOSE

Fault Location, Isolation, and Service Restoration (FLISR) Technique using IEC 61850 GOOSE

... 1) Communication Link Failure: Distribution automation applications are acquired primarily by using intact communication links between intelligent devices. However, an effective algorithm has to consider the discrepancy ...

8

A Study on Unified Testing Method for IEC 61850 Based Server with Focus on Setting Group Function

A Study on Unified Testing Method for IEC 61850 Based Server with Focus on Setting Group Function

... accepted IEC 61850 communication ...same IEC 61850 ...[2]. IEC 61850 com- munication standard is an internationally accepted standard for the exchange of information between ...

13

Analysis of end-to-end delay characteristics for various packets in IEC 61850 substation communications system

Analysis of end-to-end delay characteristics for various packets in IEC 61850 substation communications system

... Abstract— Substation plays an important role in power system communications for safe and reliable operation of entire power networks. Substation communication networks are connected with various substation intelligent ...

5

Translating proprietary protection setting data into standardized IEC 61850 format for protection setting validation

Translating proprietary protection setting data into standardized IEC 61850 format for protection setting validation

... the IEC 61850 representation format using the translation process introduced in this paper, and then inserted into the rule base for ...the IEC 61850 representation of protection settings are ...

6

Adapting LTE M 2 M Protocol Standard to Fulfil Latency Requirements for IEC 61850 GOOSE Messages

Adapting LTE M 2 M Protocol Standard to Fulfil Latency Requirements for IEC 61850 GOOSE Messages

... IEC 61850 GOOSE message over WAN presented in [2], Because of the new requirements that tends to transfer GOOSE messages within the WAN, to enhance the communication between substations, new tech- niques ...

7

An Investigation into the testing and commissioning requirements of IEC 61850 Station Bus Substations

An Investigation into the testing and commissioning requirements of IEC 61850 Station Bus Substations

... 57 of the subscribing IEDs. This task could also potentially create a mismatch with the virtual input mapping within the system configuration tool and the mapping of the virtual inputs within the IED’s internal address ...

119

Demonstration and analysis of IP/MPLS communications for delivering power system protection solutions using IEEE C37.94, IEC 61850 Sampled Values, and IEC 61850 GOOSE protocols

Demonstration and analysis of IP/MPLS communications for delivering power system protection solutions using IEEE C37.94, IEC 61850 Sampled Values, and IEC 61850 GOOSE protocols

... in IEC 61850-90-5; this is not necessary for a pure IP/MPLS network (which also has the benefit of constant latency due to the deterministic label-switched paths and packet ...

9

IEC 61850 SCL Validation Using UML Model in Modern Digital Substation

IEC 61850 SCL Validation Using UML Model in Modern Digital Substation

... The IEC 61850 standard stipulates the Substation Configuration Description Language (SCL) file as a means to define the substation equipment, IED func- tion and also the communication mechanism for the ...

23

Battery Energy Storage System Information Modeling Based on IEC 61850

Battery Energy Storage System Information Modeling Based on IEC 61850

... follows IEC 61850 standard Part 80-1 & 90-2, uses fiber Ethernet to transmit data based on TCP/IP protocol in order to ensure that the communication network has high reliability between the device layer ...

6

Architecture for automatically generating an efficient IEC 61850-based communications platform for rapid-prototyping of protection schemes

Architecture for automatically generating an efficient IEC 61850-based communications platform for rapid-prototyping of protection schemes

... of IEC 61850 in the development of new protection schemes is desirable, and becoming increasingly ...using IEC 61850 in the course of research and development activities can be costly and ...

6

Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2

Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2

... in IEC 61850 using Ethernet communication linking devices in a digital environment which are not entirely without ...Although, IEC 61850 standard lays down many guidelines in communication in ...

5

Development of IEC61850 Based Substation Engineering Tools with IEC61850 Schema Library

Development of IEC61850 Based Substation Engineering Tools with IEC61850 Schema Library

... followed IEC 61850 schema are mutually ...of IEC 61850 such as LN assignment, interlock logic, the report configuration and GOOSE configuration for data- set transferred to IEDs ...The ...

7

An open platform for rapid-prototyping protection and control schemes with IEC 61850

An open platform for rapid-prototyping protection and control schemes with IEC 61850

... particularly IEC 61850, in the course of the research and development of novel schemes can be ...the IEC 61850 standard, by providing a framework for validating SCD files and by automating ...

8

EMBEDDING RАPIDMINER MODELS IN JAVA CODE

EMBEDDING RАPIDMINER MODELS IN JAVA CODE

... uses IEC 61850 for real- time control and protection ...[26] IEC 61850 is used in the primary substation, like the grid protection, monitoring application, and renewable energy sources ...of ...

11

Enabling efficient engineering processes and automated analysis for power protection systems

Enabling efficient engineering processes and automated analysis for power protection systems

... Abstract—The reliable operation of power networks depends on the correct configuration of protection systems. These systems involve the coordination of devices across a wide area, each with numerous setting parameters. ...

9

Show all 171 documents...