• No results found

The Hot Wire Measurement

Numerical modeling of a hot-wire anemometer in turbulent flows

Numerical modeling of a hot-wire anemometer in turbulent flows

... The aim of the present thesis is therefore the development of a new numer- ical code to understand and study problems related to hot wire measurement. Spectral method represents a high order ...

94

Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry

Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry

... Abstract. Thermal environment in a vehicular cabin significantly influence drivers’ fatigue and passengers’ thermal comfort. This environment is traditionally managed by HVAC cabin system that distributes air and ...

6

Hot Wire Anemometer Applications

Hot Wire Anemometer Applications

... the wire or air intake or diameter plays a hot food processing if a change without a thermo anemometer advantages and ...a wire anemometer lies in other measuring techniques have to ...the ...

21

Measurement of Thermal Conductivity of Magnesia Brick with Straight Brick Specimens by Hot Wire Method

Measurement of Thermal Conductivity of Magnesia Brick with Straight Brick Specimens by Hot Wire Method

... the hot wire method if the relation between the tem- perature and the thermal conductivity follows the linear ...the hot wire ...the hot wire method shows a tendency to increase ...

8

Thermal conductivity measurement in clay dominant consolidated material by Transient Hot-Wire method.

Thermal conductivity measurement in clay dominant consolidated material by Transient Hot-Wire method.

... where de t ( ) / d ( ln ( ) t ) is a numerical constant deduced from the experimental data and from the linear part of the e(t)=f(ln(t)) curve. 2 Materials and method The heat transfers were measured in assemblages of ...

8

Response of an anemometer with an oscillating hot-wire.

Response of an anemometer with an oscillating hot-wire.

... The hot-wire anemometer is an instrument used for measurement of mean and fluctuating velocities in turbulent ...tungsten wire, which is heated by electrical ...the wire mainly by ...

119

Hot-wire anemometry for superfluid turbulent coflows

Hot-wire anemometry for superfluid turbulent coflows

... the hot-wire. The popularity of hot-wires in the field of hydrodynamics is due to their very high spatial and temporal resolution (see, ...that hot-wires cannot work in He II. 18 Their ...

8

DNS of a hot-wire anemometer in a turbulent channel flow

DNS of a hot-wire anemometer in a turbulent channel flow

... the measurement errors intro- duced by hot-wire anemometers in previous works is done a posteriori, based on how direct numerical sim- ulation data has to be modified to fit anemometer mea- ...a ...

7

A rapid prototyping system for the Hot Wire cutting process

A rapid prototyping system for the Hot Wire cutting process

... Figure 5.11 shows the maximum physically measured normal deviations per layer from the nominal CAD model together with the expected normal deviations for each layer. The physical measurement sample points are the ...

127

Hot-Film and Hot-Wire Anemometry for a Boundary Layer Active Flow Control Test

Hot-Film and Hot-Wire Anemometry for a Boundary Layer Active Flow Control Test

... unsteady measurement instrumentation to study how AFC manipulates the boundary layer to overcome adverse pressure gradients and flow ...both hot-wire and hot-film Constant Temperature ...

8

Hot Wire Anemometric MEMS Sensor for Water Flow Monitoring

Hot Wire Anemometric MEMS Sensor for Water Flow Monitoring

... Another class of “non-intrusive” sensors performs the measurement without affecting the flow under test, basing their interaction on energy transfer, (thermal, ultrasonic or electro-magnetic) [1-3]. These sensors ...

6

A simple digital-optical system to improve accuracy of hot-wire measurements

A simple digital-optical system to improve accuracy of hot-wire measurements

... a hot wire ...point measurement. As the wire sensor was located in the centre of the probe supports, there was a limit on the minimum achievable probe height; nevertheless this issue may be ...

17

A simple digital-optical system to improve accuracy of hot-wire measurements

A simple digital-optical system to improve accuracy of hot-wire measurements

... a hot wire ...point measurement. As the wire sensor was located in the centre of the probe supports, there was a limit on the minimum achievable probe height; nevertheless this issue may be ...

17

An Adaptive Response Compensation Technique for the Constant Current Hot Wire Anemometer

An Adaptive Response Compensation Technique for the Constant Current Hot Wire Anemometer

... the hot-wires driven at the CCA mode to realize reliable response compensation of the ...velocity measurement of the turbulent far wake of the circular cylinder by using the multi-sensor probe con- sisting ...

14

Constant Voltage Hot-Wire Anemometry for the Boundary Layer Data System

Constant Voltage Hot-Wire Anemometry for the Boundary Layer Data System

... a measurement at the lowest point and then moves on to the next ...the hot-wire is not measuring ...data measurement was taken, the voltage output from the Pitot pressure transducer, the ...

192

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

... INTRODUCTION / EN 2. INTRODUCTION The Portable Air Velocity Meter is a lightweight instrument that can be used anywhere to measure air velocity using the flexible telescoping probe, applications include ventilation hood ...

15

Development of an Autonomous Single-Point Calibration for a Constant Voltage Hot-Wire Anemometer

Development of an Autonomous Single-Point Calibration for a Constant Voltage Hot-Wire Anemometer

... the measurement of turbulence has been conducted using hot-wire ...voltage hot-wire anemometer for use with the Boundary Layer Data System ...A hot-wire calibration ...

116

Phase-averaged flow statistics in compressors using a rotated hot-wire technique

Phase-averaged flow statistics in compressors using a rotated hot-wire technique

... been developed to characterise the unsteady, three-dimen- sional flow field between compressor blade rows. Data are acquired from a slanted hot wire rotated through a number of orientations at each ...

17

Calibration Methods for a Constant Voltage Anemometer-Operated Hot-Wire in a Hypersonic Flow

Calibration Methods for a Constant Voltage Anemometer-Operated Hot-Wire in a Hypersonic Flow

... the hot-wire changes with the flow ...two wire voltages. The hot- wire overheat changes with mass flux and total temperature for a given hot-wire ...constant ...

108

An approach for Measuring Thermal Conductivity of Bricks using Transient Hot Wire method

An approach for Measuring Thermal Conductivity of Bricks using Transient Hot Wire method

... TRANSIENT HOT WIRE METHOD The transient hot wire (THW) technique is widely used for measurements of the thermal conductivity of most fluids and some attempts have also been carried out for ...

6

Show all 10000 documents...

Related subjects