[PDF] Top 20 MR of the head and neck: comparison of fast spin echo and conventional spin echo sequences

Has 10000 "MR of the head and neck: comparison of fast spin echo and conventional spin echo sequences" found on our website. Below are the top 20 most common "MR of the head and neck: comparison of fast spin echo and conventional spin echo sequences".

MR of the head and neck: comparison of fast spin echo and conventional spin echo sequences

MR of the head and neck: comparison of fast spin echo and conventional spin echo sequences

... When compared with conventional spin-echo sequences, fast spinecho sequences provided improved or equal lesion conspicuousness in a majority of head and neck lesions Table 1 and did not [r] ... See full document

7

Comparison of dynamic contrast enhanced gradient echo and spin echo sequences in MR of head and neck neoplasms

Comparison of dynamic contrast enhanced gradient echo and spin echo sequences in MR of head and neck neoplasms

... gradient-echo sequences were similar to the spin-echo im- ages, as the contrast enhancement reached an equilibrium for all tissues and the differential enhancement characteristics could not be ... See full document

9

Fast spin echo and fast fluid attenuated inversion recovery versus conventional spin echo sequences for MR quantification of multiple sclerosis lesions

Fast spin echo and fast fluid attenuated inversion recovery versus conventional spin echo sequences for MR quantification of multiple sclerosis lesions

... on MR images, and may thus simulate nor- mal brain ...with fast FLAIR sequences, could be considered more representative of the clinical status and probably more closely related to clinical disabil- ... See full document

6

Head and Neck Paragangliomas: Improved Tumor Detection Using Contrast Enhanced 3D Time of Flight MR Angiography As Compared with Fat Suppressed MR Imaging Techniques

Head and Neck Paragangliomas: Improved Tumor Detection Using Contrast Enhanced 3D Time of Flight MR Angiography As Compared with Fat Suppressed MR Imaging Techniques

... that conventional unenhanced and contrast-enhanced T1-weighted and dual T2-weighted MR imaging sequences lack a high enough sensitivity to detect ...of sequences to investigate head and ... See full document

8

Low cost high resolution fast spin echo MR of acoustic schwannoma: an alternative to enhanced conventional spin echo MR?

Low cost high resolution fast spin echo MR of acoustic schwannoma: an alternative to enhanced conventional spin echo MR?

... in MR im- aging ...a head and neck sur- geon in our institution to determine whether MR imaging should be ordered is as follows: physi- cian visit 5 $150, complete audiometry 5 $70, impedance ... See full document

6

Comparison of spin echo MR pulse sequences for imaging of the brain

Comparison of spin echo MR pulse sequences for imaging of the brain

... body MR unit, a maximal gradient field strength of 15 mT/m, a gradient rise time of ...polarized head coil. The following sequences proved to be optimal (in terms of image quality, contrast, section ... See full document

9

Comparison of MR pulse sequences in the detection of multiple sclerosis lesions

Comparison of MR pulse sequences in the detection of multiple sclerosis lesions

... comparing conventional spin-echo with fast spin-echo sequences, the number of lesions seen on both sequences was very similar ...for fast ... See full document

5

Contrast Enhancement of Intracranial Lesions: Conventional T1 Weighted Spin Echo versus Fast Spin Echo MR Imaging Techniques

Contrast Enhancement of Intracranial Lesions: Conventional T1 Weighted Spin Echo versus Fast Spin Echo MR Imaging Techniques

... Two neuroradiologists, who were blinded to the patients’ clinical history, evaluated the T1-FSE and T1-SE sequences by consensus. Both images were compared directly for lesion conspicuity using the following ... See full document

6

Half fourier acquisition single shot turbo spin echo (HASTE) MR: comparison with fast spin echo MR in diseases of the brain

Half fourier acquisition single shot turbo spin echo (HASTE) MR: comparison with fast spin echo MR in diseases of the brain

... each spin echo, so that a typical sequence might have seven spin echoes and three gradi- ent echoes between each spin echo, to allow the acquisition of 21 lines of k-space data per TR ... See full document

6

Optimization of Gray/White Matter Contrast with Fast Inversion Recovery for Myelin Suppression: A Comparison of Fast Spin Echo and Echo Planar MR Imaging Sequences

Optimization of Gray/White Matter Contrast with Fast Inversion Recovery for Myelin Suppression: A Comparison of Fast Spin Echo and Echo Planar MR Imaging Sequences

... Although this study found that EP-FIRMS im- aging was inferior to the FIRMS sequence, because geometric distortion created a need for wide BW imaging with the former, further studies of the se- quence as a single-shot ... See full document

5

Fast spin echo MR in the detection of vertebral metastases: comparison of three sequences

Fast spin echo MR in the detection of vertebral metastases: comparison of three sequences

... PURPOSE: To examine the relative capabilities for the detection of vertebral metastases of three available fast spin-echo sequences: T ]-weighted fast spin-echo, short tau inversion reco[r] ... See full document

7

Meniscal tears: comparison of the conventional spin-echo and fast spin-echo techniques through image processing

Meniscal tears: comparison of the conventional spin-echo and fast spin-echo techniques through image processing

... tears. MR images are peculiar dur- ing both the initial and later phases of meniscal tears because they show high resolution and excellent contrast between soft tissue ... See full document

8

Fat suppressed MR of the orbit and cavernous sinus: comparison of fast spin echo and conventional spin echo

Fat suppressed MR of the orbit and cavernous sinus: comparison of fast spin echo and conventional spin echo

... Qualitative evaluation for the detection of normal anatomic structures of the pericavernous region was performed and compared using fast spin-echo with and without fat suppression and fa[r] ... See full document

8

Fast Three Point Dixon MR Imaging of the Retrobulbar Space with Low Resolution Images for Phase Correction: Comparison with Fast Spin Echo Inversion Recovery Imaging

Fast Three Point Dixon MR Imaging of the Retrobulbar Space with Low Resolution Images for Phase Correction: Comparison with Fast Spin Echo Inversion Recovery Imaging

... an MR imaging pulse sequence with which the fat signal is suppressed, nulled, or alter- natively ...signal. Conventional chemical shift selection suppression, or CHESS, techniques reduce fat signal, but ... See full document

5

Preliminary clinical results with low flip angle spin echo MR imaging of the head and neck

Preliminary clinical results with low flip angle spin echo MR imaging of the head and neck

... In preliminary studies with a human volunteer and five patients with various diseases of the head and neck, conventional long TR, long TE and short TR, short TE images were compared with[r] ... See full document

6

Sagittal MR of multiple sclerosis in the spinal cord: fast versus conventional spin echo imaging

Sagittal MR of multiple sclerosis in the spinal cord: fast versus conventional spin echo imaging

... an echo train length of 5 were ...both sequences, and acquisition time was approximately 12 minutes for CSE sequences and approxi- mately 6 minutes for FSE sequences, depending on the sub- ... See full document

6

Fast spin echo imaging of the neck: comparison with conventional spin echo, utility of fat suppression, and evaluation of tissue contrast characteristics

Fast spin echo imaging of the neck: comparison with conventional spin echo, utility of fat suppression, and evaluation of tissue contrast characteristics

... Second, the use of a 256 X 192 or higher matrix in 26 of 27 patients with fast spin -echo but in only 9 of 27 conventional spin-echo examinations would tend to bias the results toward th[r] ... See full document

7

MR Diagnosis of Facial Neuritis: Diagnostic Performance of Contrast Enhanced 3D FLAIR Technique Compared with Contrast Enhanced 3D T1 Fast Field Echo with Fat Suppression

MR Diagnosis of Facial Neuritis: Diagnostic Performance of Contrast Enhanced 3D FLAIR Technique Compared with Contrast Enhanced 3D T1 Fast Field Echo with Fat Suppression

... to MR imaging ranged from 0 –30 days, and this time variability may have affected the degree of enhancement of the affected ...3D-FLAIR sequences, such as their correlation with disease severity, EPS ... See full document

5

High Resolution MR Cisternography of the Cerebellopontine Angle, Obtained with a Three Dimensional Fast Asymmetric Spin Echo Sequencein a 0 35 T Open MR Imaging Unit

High Resolution MR Cisternography of the Cerebellopontine Angle, Obtained with a Three Dimensional Fast Asymmetric Spin Echo Sequencein a 0 35 T Open MR Imaging Unit

... The imaging parameters for scans obtained at 1.5-T were the same for those used for two patients with schwannomas as those used for the two volunteers. Imaging times used for 1.5- T scans obtained from the remaining ... See full document

5

MR evaluation of vertebral metastases: T1 weighted, short inversion time inversion recovery, fast spin echo, and inversion recovery fast spin echo sequences

MR evaluation of vertebral metastases: T1 weighted, short inversion time inversion recovery, fast spin echo, and inversion recovery fast spin echo sequences

... the MR scanners at our institution underwent a software and hardware update for the introduction of the FSE and IRFSE ...both spin-echo STIR and FSE STIR, and there- fore we believe that the relative ... See full document

13