[PDF] Top 20 Multicenter Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Study for Identification of Clinically Relevant Nocardia spp
Has 10000 "Multicenter Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Study for Identification of Clinically Relevant Nocardia spp" found on our website. Below are the top 20 most common "Multicenter Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Study for Identification of Clinically Relevant Nocardia spp".
Multicenter Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Study for Identification of Clinically Relevant Nocardia spp
... This multicenter study analyzed Nocardia ...Bruker matrix-assisted laser desorp- tion ionization–time of flight mass spectrometry (MALDI-TOF ... See full document
8
Implementation of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry in Routine Clinical Laboratories Improves Identification of Coagulase Negative Staphylococci and Reveals the Pathogenic Role of Staphylococcus lugdunensis
... of identification to be determined for ...available identification systems based on phenotypic features, and false identification might often occur with these systems (see Ta- ble S1 in the ... See full document
7
Evaluation of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Identification of Nontuberculous Mycobacteria from Clinical Isolates
... MALDI-TOF identification of NTM species proved decisively superior to GenoType CM/AS both in accuracy ...turnaround time (90 min versus 8 ...NTM identification, especially for rapidly growing NTM ... See full document
5
Comparison of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry and Molecular Biology Techniques for Identification of Culicoides (Diptera: Ceratopogonidae) Biting Midges in Senegal
... first time the successful iden- tification of epidemiologically important arthropods (Culicoides ...using mass spectrometry that was performed entirely in Af- ...reproducible identification of ... See full document
9
Identification of clinical dermatophyte isolates obtained from Iran by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
... the identification of dermatophytes by using MALDI-TOF MS. The present study is the first attempt targetted toward analyzing 93 clinically important dermatophyte isolates obtained from Iran using the ... See full document
5
Prospective Evaluation of a Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System in a Hospital Clinical Microbiology Laboratory for Identification of Bacteria and Yeasts: a Bench by Bench Study for Assessing the Impact on Time to Identification and Cost Effectiveness
... Time to identification comparison. TTI calculations were available for 911 isolates completely processed during the Monday through Friday observation period each week. On the first day of workup, 87.2% of ... See full document
8
Utility of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry following Introduction for Routine Laboratory Bacterial Identification
... Matrix-assisted laser desorption–ionization time of flight mass spectrometry (MALDI-TOF MS) has been shown to be both accurate in the identification ... See full document
5
Identification of Nocardia species using matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry
... 192 Nocardia isolates using the proposed NECLC ...α-CHCA matrix was overlaid onto each sample and then ...24 mass spectra per ...single mass spectrum representing each sample was ...compiling ... See full document
8
Evaluation of the Andromas Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Aerobically Growing Gram Positive Bacilli
... Matrix-associated laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) is a rapid and simple micro- bial identification ...46 ... See full document
6
Identification of Medically Relevant Species of Arthroconidial Yeasts by Use of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry
... S pecies of the genera Trichosporon and Geotrichum occur widely in nature (1), and both are characterized by true hyphae that disarticulate into arthroconidia. Strains of these species are di- morphic and display ... See full document
10
Evaluation of the Vitek MS Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Clinically Relevant Filamentous Fungi
... mold identification has been the breadth of commercially available ...mold identification (11, ...the identification of filamentous fungi have used different MALDI-TOF MS systems, databases (both ... See full document
6
Identification of Blood Culture Isolates Directly from Positive Blood Cultures by Use of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry and a Commercial Extraction System: Analysis of Performance, Cost, and Turnaround Time
... This study has a number of ...the identification of pathogens from blood cultures, these will vary because of a number of other factors, such as the exact distribution of typical pathogens isolated, the ... See full document
5
Microbial Typing by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry: Do We Need Guidance for Data Interpretation?
... of clinically relevant bacterial ...whole-cell mass spectrometry is commonly used for species identification with potentially exploitable data already available from routine ana- ... See full document
6
Comparison of the Bruker Biotyper and Vitek MS Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Systems for Identification of Mycobacteria Using Simplified Protein Extraction Protocols
... a clinically important short- coming, as these organisms have been reported to have differing antibiotic susceptibility patterns ...recent study demonstrated the ability of MALDI-TOF MS to separate these ... See full document
9
Comparison of the Microflex LT and Vitek MS Systems for Routine Identification of Bacteria by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry
... nitrogen laser. The spectra were re- corded in the linear mode in a mass range of 2 to 20 kDa and subsequently analyzed using MALDI Biotyper Automation Control and Biotyper ...the time, the database ... See full document
13
Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Based Method for Discrimination between Molecular Types of Cryptococcus neoformans and Cryptococcus gattii
... rapid identification algorithm that incorpo- rates commercial biochemical tests, differential media, and DNA sequence analysis to distinguish clinically relevant Cryptococcus ...Our study ... See full document
5
Rapid Identification of Clinically Relevant Members of the Genus Exophiala by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry and Description of Two Novel Species, Exophiala campbellii and Exophiala lavatrina
... this study, we investi- gated the potential of matrix-assisted laser desorption–ionization time of flight mass spectrometry (MALDI-TOF MS) for the ... See full document
15
Comparison of Two Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry Methods with Conventional Phenotypic Identification for Routine Identification of Bacteria to the Species Level
... phenotype identification). Phenotypic identification using modern automated platforms costs at least approximately US$10 per isolate (list price for reagents, with- out labor costs), whereas reagents ... See full document
7
Fatal Nocardia farcinica Bacteremia Diagnosed by Matrix-Assisted Laser Desorption-Ionization Time of Flight Mass Spectrometry in a Patient with Myelodysplastic Syndrome Treated with Corticosteroids
... and time-consuming processes ...for Nocardia spp. identification from different clinical specimens [22, ...Recently, Matrix-Assisted Laser ... See full document
6
Interlaboratory Comparison of Sample Preparation Methods, Database Expansions, and Cutoff Values for Identification of Yeasts by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Using a Yeast Test Panel
... interlaboratory study using matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) to determine the ... See full document
7
Related subjects