• No results found

5 keV

A photoluminescence study of CuInSe2 single crystals ion implanted with 5 keV hydrogen

A photoluminescence study of CuInSe2 single crystals ion implanted with 5 keV hydrogen

... 2.5 keV protons demonstrated that at lower doses the intensity of the main PL emission band, present before implantation, increases whereas its spectral position shifts towards higher energies ...200 keV ...

22

Cosmic x ray surveys

Cosmic x ray surveys

... The total 2-8 keV count rates obtained from the analysis were in good agreement between the two flights,, and the ratio of 2-5 keV/5-8 keV counts in flight II indicated a source temperat[r] ...

178

On the cyclotron line in Cepheus X 4

On the cyclotron line in Cepheus X 4

... An epoch folding search (Leahy et al. 1983) was used to deter- mine the source pulse period for each observation (see Table 1). The pulse profiles were generated by folding the lightcurves at a period of 66.30 s. The ...

7

Excitonic model of track registration of energetic heavy ions in insulators

Excitonic model of track registration of energetic heavy ions in insulators

... In materials in which excitons are not self- trapped, the critical stopping power is higher by a factor of 4±8. Since there is no source of localisa- tion of electron±hole pairs, at least 1/3 of the en- ergy will di€use ...

5

High-resolution evaluation of the U5(n,f) cross section from 3 keV to 30 keV

High-resolution evaluation of the U5(n,f) cross section from 3 keV to 30 keV

... The high degree of coincidence found between the Paradela data at CERN-nTOF and those of Weston at ORNL is confirmed by other high-resolution datasets. More than 280 peaks have been unambiguously identified, distributed ...

9

Short-lived isomers in192Po and 194Po

Short-lived isomers in192Po and 194Po

... In the γ -γ coincidence analysis, we selected events from the correlation chains (ER-γ -γ )-α( 194 Po). Coincidences are shown in Fig. 4 and coincident transitions are listed in Table III. The results agree with the ...

13

Calibration of the High Purity Germanium Gamma Ray Spectrometer in CERT, ABU Zaria, Nigeria

Calibration of the High Purity Germanium Gamma Ray Spectrometer in CERT, ABU Zaria, Nigeria

... Source-detector geometry is an important factor in bringing out the major characteristics of HPGe detectors. Going by the ANSI/IEEE standard, 1996, a geometry of 25 cm is usually chosen to evaluate values of relative ...

7

Quantification of uranium-238 in environmental samples using gamma-ray spectrometry

Quantification of uranium-238 in environmental samples using gamma-ray spectrometry

... 63 keV (doublet), 92.5 keV (dou- blet), 767 keV and 1001 ...1001 keV are robust for quantification but due to their low emission probabilities ...63 keV and ...

12

Arithmatical consequences of two identities of B  Gordon

Arithmatical consequences of two identities of B Gordon

... alternate proof of Ramanujan’s theorem on the divisibility of certain values of the partition function by the modulus 5... KEV WORDS AND PHRASES..[r] ...

8

Microchannel Plates in Mass Spectrometer Instruments for Spacecraft, Nicholas Kenneth Lubinsky

Microchannel Plates in Mass Spectrometer Instruments for Spacecraft, Nicholas Kenneth Lubinsky

... 15 keV, we measure just about 5 keV, for approx. 10 keV loss, but at 24 keV initial energy, we measure an energy of about 8 keV, for a much larger loss of 16 ...

186

Vorren_unc_0153D_17010.pdf

Vorren_unc_0153D_17010.pdf

... The data that was presented represents only 478 kg d of exposure from Module 1 com- missioning data. During commissioning, multiple issues were still being addressed, including the energy-scale calibration and electronic ...

157

Analytical Calculation of the Compton Single Scatter Component of Pencil Beam Scatter Kernel for Scatter Correction in kV Cone Beam CT (kV CBCT)

Analytical Calculation of the Compton Single Scatter Component of Pencil Beam Scatter Kernel for Scatter Correction in kV Cone Beam CT (kV CBCT)

... The X-ray scatter consists of any secondary photons other than the incident primary photons and is mainly produced by direct photon interactions with medium, including Compton (incoherent) and Rayleigh (coherent) ...

17

ATTENUATION COEFFICIENT OF GLUCOSE SOLUTION USING GAMMA SOURCE

ATTENUATION COEFFICIENT OF GLUCOSE SOLUTION USING GAMMA SOURCE

... Teli, L.M.Chaudhari&S.S.Malode ,Attenuation coefficients of 123 keV gamma radiation by dilute solution of sodium chloride, Appli.. Teli, L.M.Chaudhari, Attenuation coefficient of 662 keV[r] ...

7

Radiation effects in zinc oxide:zinc under bombardment with KeV ions.

Radiation effects in zinc oxide:zinc under bombardment with KeV ions.

... In the KeV range loses most of its energy to electrons.. A.)]and below about 25 KeV the observed electronic stopping cross. sections generally agree quite well with [r] ...

79

Zum Zerfall des 241Am — Die Intensität der Konversionselektronen des 26,4 keV  und des 33,2 keV Übergang im 237Np  EUR 2632  = On the decay of 241Am — Intensity of conversion electrons in 26 4 keV and 33 2 keV passages in 217Np  EUR 2632

Zum Zerfall des 241Am — Die Intensität der Konversionselektronen des 26,4 keV- und des 33,2 keV-Übergang im 237Np. EUR 2632. = On the decay of 241Am — Intensity of conversion electrons in 26.4 keV and 33.2 keV passages in 217Np. EUR 2632.

... Dadurch konnten sowohl in einer als auch in beiden Hälften des Zählrohres entweder die α­Strahlen allein oder die α­Strahlen zusammen mit den Elektronen sowie auch Koinzidenzen zwischen [r] ...

42

D-D nuclear fusion processes induced in polyethylene foams by TW Laser-generated plasma

D-D nuclear fusion processes induced in polyethylene foams by TW Laser-generated plasma

... The use of thin targets in TNSA regime permits the occurrence of high ion acceleration in forward direction, from the rear side of the target, above 1 MeV per charge state, but low yield is produced due to the limited ...

6

Low lying oscillations of deformed nuclei

Low lying oscillations of deformed nuclei

... 4. T. Nikšić et al.,Phys. Rev. C 79, 034303 (2009) 5. Z. P. Li et al., Phys. Rev. C 79, 054301 (2009) 6. J.P. Delaroche et al, ,Phys. Rev. C 81, 014303 (2010) 7. J. Decharge and D. Gogny, Phys. Rev. C21, 1568 ...

5

Comparing of Microhardness of the Stellite 6 Cobalt Alloy Implanted with 175 keV Mn+ Ions and 120 keV N+ Ions

Comparing of Microhardness of the Stellite 6 Cobalt Alloy Implanted with 175 keV Mn+ Ions and 120 keV N+ Ions

... The increase in the load to 5 gf resulted in an increase in the depth of microhardness tester penetration. The mean indexation depth for all the samples exceeded 0.71 um. The results of micro- hardness ...

7

GAMMA RAY INTERACTION STUDIES ON SOME SHAPE MEMORY ALLOYS  IN THE ENERGY RANGE 122 KEV TO 1330 KEV

GAMMA RAY INTERACTION STUDIES ON SOME SHAPE MEMORY ALLOYS IN THE ENERGY RANGE 122 KEV TO 1330 KEV

... measured at 122 keV to 1330 keV photon energies for some shape memory alloys i.e. cast Iron, Nitinol, Babit Metal, Stelite, Amalgam carried out by NaI (Tl) scintillation detector with a well collimated ...

9

Dynamics and Tolerance of Superionics in Extreme Environment.

Dynamics and Tolerance of Superionics in Extreme Environment.

... undergoes cooperative sequential motion? This fraction is identified by considering all the annihilated oxygen interstitials that have made replacement jumps onto neighboring oxygen sites and evaluating the fraction that ...

148

Show all 10000 documents...

Related subjects