• No results found

balanced three-phase load

Fuzzy Controlled Based IPQC at Various Load Conditions for Improvement of Power Quality

Fuzzy Controlled Based IPQC at Various Load Conditions for Improvement of Power Quality

... ABSTRACT: This paper presents a hybrid fuzzy logic controlled based improved power quality conditioner used to counterbalance for harmonic distortion in three-phase system. The IPQC employs a very simplest ...

7

A Novel Multifunctional Distributed Compensation Scheme for Stiff Source connected Induction motors

A Novel Multifunctional Distributed Compensation Scheme for Stiff Source connected Induction motors

... four-wire three-phase shunt-connected ...a balanced sinusoid, irrespective of the unbalance and distortion in voltage in the supply side or line ...the load terminal during voltage ...

7

Balance Automatic Control System Load 3 Phase

Balance Automatic Control System Load 3 Phase

... of three-phase electrical load balance, can be measured unbalanced and balanced current on the sensor input side (table 1) and the voltage at the output side of the phase sensor R, S, T ...

5

Power Quality Improvement by using Shunt Active Power Filter

Power Quality Improvement by using Shunt Active Power Filter

... a three-phase balanced and unbalanced composite load ...(linear load and non-linear load) by using shunt active power ...both three-phase balanced and ...

6

Research on a New Control Strategy of Three Phase Inverter for Unbalanced Loads

Research on a New Control Strategy of Three Phase Inverter for Unbalanced Loads

... of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are ...a balanced three phase output voltage under ...

6

Enhancement of Power Quality Using Self Supported DVR

Enhancement of Power Quality Using Self Supported DVR

... Fig.3. Three phase source voltages Vsa, Vsb and Vsc are connected to the three-phase critical load through series impedance Za, Zb and Zc and an injection transformer in each ...and ...

5

Enhancement of Power Quality by Employing Dynamic Voltage Restorer

Enhancement of Power Quality by Employing Dynamic Voltage Restorer

... Fig.3. Three phase source voltages Vsa, Vsb and Vsc are connected to the three-phase critical load through series impedance Za, Zb and Zc and an injection transformer in each ...and ...

5

Three-Phase Balanced Voltage SAGS Mitigation By Using Voltage Compensator

Three-Phase Balanced Voltage SAGS Mitigation By Using Voltage Compensator

... For this project, proposed method to be used for mitigating the voltage sags is Dynamic Voltage Restorer (DVR). It actually works by adding extra voltage during voltage occur or called ‘missing’ voltage. Basically, this ...

24

Load characterization and revenue metering under non sinusoidal and asymmetrical operation

Load characterization and revenue metering under non sinusoidal and asymmetrical operation

... the load is the combination of three wye- connected unbalanced resistive loads and three delta- connected balanced ...in load modelling and propagate them into the accountability ...of ...

9

Interactions between Distributed Energy Resources in a Balanced Three-Phase Microgrid.

Interactions between Distributed Energy Resources in a Balanced Three-Phase Microgrid.

... Also, due to the increased interference of digital systems and sophisticated controls, many in- dustrial, commercial and residential customers now require a high level of power quality. Power quality, availability and ...

124

Injection of Balanced Three-Phase Currents with Fuzzy Control of Three-Phase Bidirectional Csc Under Unbalanced Grid Voltage Condition

Injection of Balanced Three-Phase Currents with Fuzzy Control of Three-Phase Bidirectional Csc Under Unbalanced Grid Voltage Condition

... Fig.1. Bidirectional current source converter. Under such condition, the converter would trip if one of the phase currents exceeded the rated value. This may cause system instability and cascaded failure of the ...

9

Vol 3, No 11 (2015)

Vol 3, No 11 (2015)

... with balanced three-phase output voltages and currents with low ...lower load, i.e., 12.5%. The balanced three-phase output is obtained even at such a reduced load ...

11

Novel Load Flow Algorithm for Multi-Phase Balanced/ Unbalanced Radial Distribution Systems

Novel Load Flow Algorithm for Multi-Phase Balanced/ Unbalanced Radial Distribution Systems

... of three phase distribution load ...solving three-phase radial distribution ...A three-phase fast decoupled power flow method has been proposed in ...unbalanced ...

15

THREE-PHASE ACTIVE POWER FILTER CONTROLLER FOR BALANCED AND UNBALANCED NON-LINEAR LOAD

THREE-PHASE ACTIVE POWER FILTER CONTROLLER FOR BALANCED AND UNBALANCED NON-LINEAR LOAD

... A three- phase insulated gate bipolar transistor based current controlled voltage source inverter with a dc bus capacitor is used as an active ...for three-phase active power filter controller ...

11

A Novel Method to Improve the Performance Of DSTATCOM Using Deadbeat Predictive Control Algorithm

A Novel Method to Improve the Performance Of DSTATCOM Using Deadbeat Predictive Control Algorithm

... of load currents to make source currents balanced, sinusoidal, and in-phase with respective phase load voltages In the previous research, the compensator with three ...

8

AN UNBALANCED LOAD CONTROL FOR THREE PHASE POWER CONVERTER IN DISTRIBUTION SYSTEM

AN UNBALANCED LOAD CONTROL FOR THREE PHASE POWER CONVERTER IN DISTRIBUTION SYSTEM

... linear load, nonlinear load, and motors start-up, or while a disturbance happened on the grid ...a balanced linear load that demand 2 kW (0.655 kW per phase) of more active power from ...

7

Harmonic identification and compensation 
		in distribution system with non linear and linear loads using shunt APF

Harmonic identification and compensation in distribution system with non linear and linear loads using shunt APF

... of three-phased linear & three phase nonlinear load with DC RL-load with load shifting by load/source side with specific load impedances at node C & B, a ...

10

Design And Development Of A Three Phase Shunt Active Power Filter For Harmonics Reduction In Industrial Using Matlab, Simulink

Design And Development Of A Three Phase Shunt Active Power Filter For Harmonics Reduction In Industrial Using Matlab, Simulink

... Harmonic content in the electrical system will cause a waveform of voltage or current in the electrical system to be distorted. This situation is very critical because it will interfere with other electrical systems. ...

24

Improvement of Power-Quality by using a Voltage-Controlled DSTATCOM

Improvement of Power-Quality by using a Voltage-Controlled DSTATCOM

... First, discrete modelling of the system is presented to obtain a discrete voltage control law, and it is shown that the PCC voltage can be regulated to the desired value with properly chosen parameters of the VSI. Then, ...

6

Unified Power Quality Conditioner (UPQC) using MATLAB

Unified Power Quality Conditioner (UPQC) using MATLAB

... © 2016, IRJET | Impact Factor value: 4.45 | ISO 9001:2008 Certified Journal | Page 2413 For the removal of harmonics from current, the distorted current is converted into two-phase stationary co- ordinates using ...

7

Show all 10000 documents...

Related subjects