• No results found

DC fault

Analysis of DC fault for dual active bridge DC/DC converter including prototype verification

Analysis of DC fault for dual active bridge DC/DC converter including prototype verification

... presents DC fault analysis for a dual active bridge DC/DC converter which comprises of two active bridges and an internal medium frequency ...The DC fault study assumes the ...

26

Review of DC fault protection for HVDC grids

Review of DC fault protection for HVDC grids

... block DC faults but also provide flexible control, as listed in Table ...where DC faults occur relatively frequently compared to its counterpart with ...extinguish fault current and deionize the arc, ...

20

Submodule configuration of HVDC-DC auto transformer considering DC fault

Submodule configuration of HVDC-DC auto transformer considering DC fault

... any DC voltage ...considering DC fault has been presented, including normal operation, fault isolation and continuous operation of the healthy converters after ...healthy DC grids may ...

24

DC fault protection strategy considering DC network partition

DC fault protection strategy considering DC network partition

... single fault on part of the DC ...every DC line connection points though with large increase of system ...of DC fault events and the inconsistency of power generation from wind farms, ...

5

DC fault parameter sensitivity analysis

DC fault parameter sensitivity analysis

... MMC converters generally consist of many hundreds of cells and in conventional models each of these would be modeled at the switch level. As the number of voltage levels increases so does the number of cells, and ...

6

AC/DC converter with DC fault suppression for aircraft +/- 270 VDC distribution systems

AC/DC converter with DC fault suppression for aircraft +/- 270 VDC distribution systems

... reliable DC fault protection, the paper also investigates DC fault suppression mechanism of an alternative VSC topology, which is adapted from high voltage power systems and modified according ...

12

Active control of DC fault currents in DC solid-state transformers during ride-through operation of multi-terminal HVDC systems

Active control of DC fault currents in DC solid-state transformers during ride-through operation of multi-terminal HVDC systems

... the fault current di/dt and decrease the fault current ...the fault to avoid overcurrents, causing shutdown of the entire multi- terminal HVDC ...series dc inductors and slow DCCBs are used to ...

11

Research on Parameter Collaborative Configuration of DC Circuit Breaker  and DC Fault Current Limiter

Research on Parameter Collaborative Configuration of DC Circuit Breaker and DC Fault Current Limiter

... Engineering DC fault current suppression in the DC distribution ...the DC circuit breaker is still in the stage of theoretical research and prototype development, which can be divided into ...

14

DC Microgrids: Architectures, Control and Economic Analysis.

DC Microgrids: Architectures, Control and Economic Analysis.

... the fault happens very close to the converter in fact at the converter DC link, R is small compared to L and the time constant is high ...the DC fault occurs 200m away from the converter and ...

226

Fault analysis of an active LVDC distribution network for utility applications

Fault analysis of an active LVDC distribution network for utility applications

... generate DC power, and directly supply DC loads without conversion ...for DC fault detection, and isolation. DC fault currents normally have high di/dt, and this will make the ...

6

DC/DC converters based on hybrid MMC for HVDC grid interconnection

DC/DC converters based on hybrid MMC for HVDC grid interconnection

... of DC grids with similar or different voltage levels and the power flow control among them have become one of the main barriers for the development of large scale HVDC transmission ...the DC/DC ...

6

Validation of fast and selective protection scheme for an LVDC distribution network

Validation of fast and selective protection scheme for an LVDC distribution network

... advanced DC protection scheme which can detect, locate, and interrupt DC faults on an active LVDC distribution network within ...sensing DC current directions at an early stage of the fault ...

8

Limitation of Fault Currents by Positioning of Superconducting Fault Current Limiter in AC and DC Microgrid

Limitation of Fault Currents by Positioning of Superconducting Fault Current Limiter in AC and DC Microgrid

... and dc microgrid, distribution and transmission infrastructure will best able to handle allowing for distributed generation such as wind turbines, photovoltaic (PV) farms and other electric power ...a fault ...

7

ADAPTIVE DC POWER SUPPLY AND FAULT IDENTIFICATION

ADAPTIVE DC POWER SUPPLY AND FAULT IDENTIFICATION

... hybrid dc micro-grid will be investigated with help of event-based protection ...for fault study of the system and results will be ...of fault occurring in the system. Fault current method ...

5

Voltage Compensation Using D-Statcom under Unsymmetrical Faults in Distribution Systems with Static Power Converter Fed Dc Motor Load

Voltage Compensation Using D-Statcom under Unsymmetrical Faults in Distribution Systems with Static Power Converter Fed Dc Motor Load

... line fault occurs on the feeder which is feeding DC motor load the voltage sag occurs in the faulted ...line-line fault leads to the open-conductor fault (with two phase ...

8

In Three Level DC - DC Converters Protection Schemes for Various Fault Conditions

In Three Level DC - DC Converters Protection Schemes for Various Fault Conditions

... The transformer winding over-voltage breakdown results in secondary winding short circuit. The resonant capacitor is discharged to 0 suddenly, which is similar to the case of short circuit of one of rectifier diodes. The ...

9

Protection Schemes for Various Fault Conditions of Three Level Dc -Dc Converters

Protection Schemes for Various Fault Conditions of Three Level Dc -Dc Converters

... The behavior of the flying capacitor voltage Vcss under various fault conditions in the three-level parallel resonant converter .The most common faults associated with the active devices and load, including open- ...

9

An alternative protection strategy for multi-terminal HVDC

An alternative protection strategy for multi-terminal HVDC

... DC breakers are installed at the central node of the system in order to isolate the fault from the healthy section of system (Figure 1). There has been a large amount of literature published in the area on ...

6

A Modular Multilevel DC/DC Converter with Fault Blocking Capability for HVDC Interconnects

A Modular Multilevel DC/DC Converter with Fault Blocking Capability for HVDC Interconnects

... The DC-MMC operation in greater depth, by utilizing a simplified string model to study the otherwise indicated, the following assumptions are enforced: 1) each arm has a large number of SMs such that ideal ...

11

Examining fault behaviour of a superconducting DC network

Examining fault behaviour of a superconducting DC network

... specific fault behaviour of the novel components must also be in ...superconducting DC networks and key associated components (such as superconducting cables and ...

7

Show all 9589 documents...