• No results found

discontinuous current and voltage mode

Analysis and modeling of buck converter in discontinuous output inductor current mode operation

Analysis and modeling of buck converter in discontinuous output inductor current mode operation

... input current continuous and less of ...output voltage is lower than the peak input ...in discontinuous output inductor current mode has resistive and constant input impedance with a ...

8

A Bridgeless High Power Factor Buck Converter Based Dual Output SMPS

A Bridgeless High Power Factor Buck Converter Based Dual Output SMPS

... Switched Mode Power Supplies are widely used for powering up different parts in a personal computer by generating multiple Dc voltages from single phase AC ...input current at high power ...in ...

8

A Review of AC-DC Fly back Converter for Variable Speed PMSM Drive for Power Quality Improvement

A Review of AC-DC Fly back Converter for Variable Speed PMSM Drive for Power Quality Improvement

... ________________________________________________________________________________________________________ Abstract--This review paper provides a Simulation And Analysis Of AC-DC Fly back Converter which is operated in ...

6

Analysis and Modeling of Buck Converter in  Discontinuous Output Inductor Current  Mode Operation

Analysis and Modeling of Buck Converter in Discontinuous Output Inductor Current Mode Operation

...   (3) If the switching period Ts is much smaller than the input cycle Ti, the input voltage can be considered con- stant over one switching cycle [3]. Then, the input volt- age i in (1), (3) can be directly ...

7

Design and Simulation of Cuk Converter-Fed BLDC Motor Drive for PFCwith Fuzzy Logic Controller

Design and Simulation of Cuk Converter-Fed BLDC Motor Drive for PFCwith Fuzzy Logic Controller

... switching mode to reduce its switching losses ...a current multiplier approach is shown in Fig.1 i.e. the current flowing in the input and output inductors (L Lo), and the voltage across the ...

11

Power Factor Improvement of Bridgeless Isolated Cuk Converter-Fed Brushless DC Motor Drive Using Fuzzy Controller

Power Factor Improvement of Bridgeless Isolated Cuk Converter-Fed Brushless DC Motor Drive Using Fuzzy Controller

... of voltage (or current) to the voltage (or current) of the ...of mode of operation is a tradeoff between the allowed stresses on PFC switch and cost of the around system during the ...

9

 EDUCATIONAL MODELLING IN CLOUD COMPUTING USING IMS LEARNING DESIGN

 EDUCATIONAL MODELLING IN CLOUD COMPUTING USING IMS LEARNING DESIGN

... input voltage and produces higher output ...conduction mode to get higher input power factor and low Total Harmonic Distortion (THD) [1], [2] at the cost of complex and costlier ...output voltage in ...

6

Fuzzy Logic Controlled based PFC Cuk Converter Fed BLDC Motor Drive

Fuzzy Logic Controlled based PFC Cuk Converter Fed BLDC Motor Drive

... a current multiplier and a voltage follower approach ...and voltage control, whereas insulated gate bipolar transistor’s (IGBT) are used in the VSI for its low frequency ...switching mode to ...

9

Design of bridgeless high power factor buck converter operating in discontinuous capacitor voltage mode

Design of bridgeless high power factor buck converter operating in discontinuous capacitor voltage mode

... high current stress associated with DICM operation can be overcome by operating the converter in DCVM ...operation mode offers soft turn-off switch capability; the soft turn-off capability allows using ...

6

PFC Based DC Variable Voltage Converter Fed BLDC Motor Drive

PFC Based DC Variable Voltage Converter Fed BLDC Motor Drive

... bus voltage of voltage source inverter ...in discontinuous inductor current mode (DICM) is used for dc-bus voltage control with unity power factor at ac ...dc-bus voltage ...

11

Power factor correction using Bridgeless isolated  CUK Converter

Power factor correction using Bridgeless isolated CUK Converter

... link voltage feeding BLDC motor is used for its speed ...in discontinuous inductor current mode to achieve the unity power ...single voltage sensor is used in order to reduce the total ...

6

Implementation of Discontinuous Inductor Current Mode in Cuk Converters fed brushless Dc Motors

Implementation of Discontinuous Inductor Current Mode in Cuk Converters fed brushless Dc Motors

... 3) Mode III: Fig. 3f shows the DCM of operation. In this mode, none of the energy is left in the output inductor Lo1, that is, iLo1 = ...The voltage across intermediate capacitor C1 and ...

8

A Novel Zeta Converter with Pi Controller for Power Factor Correction in Induction Motor

A Novel Zeta Converter with Pi Controller for Power Factor Correction in Induction Motor

... dc-link voltage of the voltage source inverter (VSI) feeding induction motor ...in discontinuous inductor current mode; thus utilizing a voltage follower approach which requires ...

5

Brushless DC Motor Drive using an Isolated Luo Converter for Power Factor Correction

Brushless DC Motor Drive using an Isolated Luo Converter for Power Factor Correction

... in discontinuous inductor current mode (DICM) requires only single voltage sensor for voltage control and inherent PFC is achieved at AC ...this mode of operation and, therefore ...

8

Fuzzy Control Based Micro-grid System with a Back to Back Converter

Fuzzy Control Based Micro-grid System with a Back to Back Converter

... the voltage of the DC-link in a back to back converter at a constant value, the active power that flows into the DC-link must be equal to the active power absorbed by the ...the voltage of the capacitor ...

8

Development of a non pulsating buck boost converter with continuous current mode (CCM)

Development of a non pulsating buck boost converter with continuous current mode (CCM)

... Nowadays, the control systems for many power electronic appliances have been increasing widely. Crucial with these demands, many researchers or designers have been struggling to find the most economic and reliable ...

35

Analysis and control of modular multilevel converters under asymmetric arm impedance conditions

Analysis and control of modular multilevel converters under asymmetric arm impedance conditions

... arm current is larger than the lower arm current (due to the smaller arm inductance in the upper arm), and the common-mode current includes large 50 Hz and 100 Hz ripple ...ac current ...

11

New Current-mode Universal Filter by a Novel Low Voltage Second Generation Current Conveyor

New Current-mode Universal Filter by a Novel Low Voltage Second Generation Current Conveyor

... generation current conveyor (CCII) was first expanded by Sedra and Smith in 1970[1] and today, one of the state-of-the-art subjects which is considered by analog current mode circuit researchers is ...

6

A Novel Dynamic Voltage Restorer with Cascaded H-Bridge Inverter

A Novel Dynamic Voltage Restorer with Cascaded H-Bridge Inverter

... In order to perform post-fault compensation, the measurement unit determines depth of voltage sag and phase of the source voltage. On the basis of this data, the control system will then generate a ...

10

Digitally Programmable Voltage Mode Quadrature Oscillator Using Current Conveyors

Digitally Programmable Voltage Mode Quadrature Oscillator Using Current Conveyors

... using current conveyor as a basic building ...two current conveyors, three grounded resistors, one grounded capacitor and one floating resistor and capacitor, is ...

7

Show all 10000 documents...

Related subjects