• No results found

First Separation using the microfluidic DFGF

A Microfluidic Device for Ultrasonic Separation

A Microfluidic Device for Ultrasonic Separation

... a microfluidic flow through separator, and is an extension of previous work performed by Hawkes and Coakley at Cardiff University into similar devices [2, ...fabricated using traditional techniques, ...

6

Microfluidic Approaches for Cancer Cell Separation: Review

Microfluidic Approaches for Cancer Cell Separation: Review

... cell separation yield and purity compared to micro-filtra- tion methods that are based on cell size differences ...multi-module microfluidic system for cancer cell capture in which the first module ...

15

Design and Experimental Validation of Continuous DNA Separation using ITP-Based Microfluidic Device

Design and Experimental Validation of Continuous DNA Separation using ITP-Based Microfluidic Device

... Many microfluidic approaches have been explored to attempt to overcome the limitations inherent to the large-volume batch- based processes of ...recent microfluidic free-flow electrophoresis (FFE) devices ...

9

Particle separation in microfluidic devices - SPLITT fractionation and microfluidics

Particle separation in microfluidic devices - SPLITT fractionation and microfluidics

... the first considers an ultrasonic cell washing system that can be used to transfer cells or particles from one liquid medium to another (washing), whilst the second example considers the separation of ...

22

Design and Verification of a  Blood Cell Separation Microfluidic Device

Design and Verification of a Blood Cell Separation Microfluidic Device

... microparticles separation method proposed in the ...tested using a theoretical model as well as experimental ...described using a Markovian ...

8

Formal Verification of a Microfluidic Device for Blood Cell Separation

Formal Verification of a Microfluidic Device for Blood Cell Separation

... based microfluidic device, with IDT electrodes, they developed for sorting of ...approximated using a trigonometric function for realizing an analytical equation of the trajectory of the ...

9

Phase separation of multiphase droplets in a digital microfluidic device

Phase separation of multiphase droplets in a digital microfluidic device

... the first comprehensive investigation of separation of the immiscible phases of multiphase droplets in digital microfluidics (DMF) ...Phase separation performance in terms of percentage residue of ...

10

Reconfigurable particle separation by dynamic acoustic fields in microfluidic devices

Reconfigurable particle separation by dynamic acoustic fields in microfluidic devices

... The first method relies on changing the acoustic contrast factor and the custom made mi- cro-particle move from node to antinode of the acoustic ...good separation perform- ance, up to ...

7

Separation of Negatively Charged TiO2-Coated Polystyrene Beads in Microfluidic Device

Separation of Negatively Charged TiO2-Coated Polystyrene Beads in Microfluidic Device

... the microfluidic devices with actual spermatozoa, negatively charged TiO 2 -coated Ps-beads were crafted by sputtering and O 2 plasma ...characterized using XRD, SEM-EDS, and ...analysis using XAS ...

15

Numerical investigation of cell encapsulation for multiplexing diagnostic assays using novel centrifugal microfluidic emulsification and separation platform

Numerical investigation of cell encapsulation for multiplexing diagnostic assays using novel centrifugal microfluidic emulsification and separation platform

... centrifugal microfluidic platform for emulsification and ...phase using facile bifurcated junction ...droplets using the centrifugal microfluidic platform by computational fluid dynamics ...

14

Blood cells separation and sorting techniques of passive microfluidic devices: From fabrication to applications

Blood cells separation and sorting techniques of passive microfluidic devices: From fabrication to applications

... 4.3. Microfluidic Filters-Physical Filtration Techniques Combined with the mentioned separation techniques, microfluidic filters are usually introduced to increment the efficiency of the ...

20

Direct current insulator based dielectrophoresis (DC-iDEP) microfluidic chip for blood plasma separation

Direct current insulator based dielectrophoresis (DC-iDEP) microfluidic chip for blood plasma separation

... (H-DC-iDEP) microfluidic blood plasma separation Evaluation and diagnosis of blood alterations is a common request for clinical laboratories requiring a complex technological approach and dedication of ...

125

Construction of microfluidic chips using polydimethylsiloxane for adhesive bonding{

Construction of microfluidic chips using polydimethylsiloxane for adhesive bonding{

... Microfluidic experiments were carried out on an Axiovert 135 (Carl Zeiss, Thornwood, NY) inverted microscope having long working distance objectives (Zeiss LD Achroplan 206 and 406). The CE separation uses ...

6

Microfluidic Analytical System with On Line Luminol Chemiluminescence Detection Based on Annular Flow of Phase Separation Multiphase Flow

Microfluidic Analytical System with On Line Luminol Chemiluminescence Detection Based on Annular Flow of Phase Separation Multiphase Flow

... we first examined luminol chemiluminescence (CL) behavior in a ternary mixed solvent solution of water-acetonitrile-ethyl acetate, and the mixed solvent solution was found to enhance luminol CL in time and ...

11

Integrated Microfluidic Isolation of Aptamers Using Electrophoretic Oligonucleotide Manipulation

Integrated Microfluidic Isolation of Aptamers Using Electrophoretic Oligonucleotide Manipulation

... to microfluidic SELEX that fully integrates all steps of the SELEX process on a single ...existing microfluidic SELEX efforts, significantly simplify the manipulation of target molecules and ...

10

Development of multidimensional separations using microfluidic devices for proteomics applications

Development of multidimensional separations using microfluidic devices for proteomics applications

... 84 between consecutive CE injections should have been at least 5.25 s to prevent this from occurring. For the LC-CE-MS analysis in Figure 4-5B, the estimated peak capacities for the LC and CE dimensions were 55 and 11, ...

170

Highly Efficient Adenoviral Transduction of Pancreatic Islets using a Microfluidic

Highly Efficient Adenoviral Transduction of Pancreatic Islets using a Microfluidic

... featured 8 hydrodynamic traps connected in parallel with a fixed width main channel (widths at various positions indicated by double-headed arrows). In Spiral 2, the width of the main channel from the exit of each ...

9

On chip separation of spermatozoa using dielectrophoresis

On chip separation of spermatozoa using dielectrophoresis

... The first 8 seconds of the experiment no voltage is applied to the electrodes. From 8 to 60 seconds the above voltage is applied to the electrodes. It can be observed that spermatozoa cannot pass the electrodes. ...

78

Separation and Localisation of P300 Sources and Their Subcomponents Using Constrained Blind Source Separation

Separation and Localisation of P300 Sources and Their Subcomponents Using Constrained Blind Source Separation

... 1 This can be facilitated as part of the original Infomax algorithm where the activation function should ideally be derived from the pdfs of the sources. multichannel EEGs. One important factor in applying CBSS is the ...

10

Control of Perfusable Microvascular Network Morphology Using a Multiculture Microfluidic System

Control of Perfusable Microvascular Network Morphology Using a Multiculture Microfluidic System

... This can be inferred from the significant differences found in the microvasculature of various organs in vivo and across species. 1 For instance, islet cells cannot survive separation distances from the nearest ...

11

Show all 10000 documents...

Related subjects