Study Response of Fixed Base and Isolation Base

Study Response of Fixed Base and Isolation Base

... The base isolation system separates the structure from its foundation and primarily moves the natural frequency of the structure away from the excitation frequency range through its low stiffness relative to that ...

8

A Review Paper on Comparative Study of Fixed Base, Base Isolation & Damper System in RC Building

A Review Paper on Comparative Study of Fixed Base, Base Isolation & Damper System in RC Building

... viz. base isolation at the foundation, above the foundation and in between the columns to know the stability of LRB isolated buildings by analyzing based on the dynamic linear seismic analysis in ...a fixed ...

5

Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphragm Discontinuity

Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphragm Discontinuity

... As a result of the increased flexibility of the system, the Time period which is the number of seconds for the building to vibrate back and forth is 0.702 sec in fixed condition and is increased to 1.255 sec. If ...

5

Comparison of Seismic Behavior of Building with Fixed Base, Base Isolator and Shear Wall

Comparison of Seismic Behavior of Building with Fixed Base, Base Isolator and Shear Wall

... using base isolators, shear walls and minimize the damage of ...with fixed base, base isolator (rubber isolator), and damper and shear ...and base shear are compared for building with ...

5

Behavior of Symmetric Frame Structure with Base Isolator and Fixed Base Building

Behavior of Symmetric Frame Structure with Base Isolator and Fixed Base Building

... a fixed-base building frame and the isolated-base building frame under seismic ...on. Base isolation technology is a viable alternative to conventional earthquake-resistant design of ...

5

Comparative Study on Fixed Base and Base Isolated for Building on Sloping Ground

Comparative Study on Fixed Base and Base Isolated for Building on Sloping Ground

... to fixed base ...and base reactions for 0°,10°,20°,30 sloped ground, it conclude that the base isolation device (LRB) is suitable for low to medium rise ...

6

Comparative Study on Fixed base and Base Isolated Buildings on Sloping Ground

Comparative Study on Fixed base and Base Isolated Buildings on Sloping Ground

... that base shear versus different slope, it is observed that base shear of fixed base building is more than base isolated ...building. Base isolation increases the flexibility of ...

17

Comparative Study of Base Isolated Building with Fixed Base Building with Time History Analysis

Comparative Study of Base Isolated Building with Fixed Base Building with Time History Analysis

... collapse. Base isolation is one of the best and widely accepted passive control device to resist these forces by isolating the superstructure from the sub ...of base isolated building and fixed ...

7

Comparative Study on Cost Benefit Analysis of Lead Rubber Isolated Base and Fixed Base Steel Structures

Comparative Study on Cost Benefit Analysis of Lead Rubber Isolated Base and Fixed Base Steel Structures

... both base isolated and fixed base supported, under earthquake excitations is investigated taking into account the respective total construction cost and base isolation cost including ...

6

Evaluation of Fixed Base vs. Base Isolated Building Systems

Evaluation of Fixed Base vs. Base Isolated Building Systems

... seismic base isolation. The modeling procedure of not only fixed base but also of base isolated building in ETAB software is carried out and also ...on base isolation system is ...

10

Analytical Comparison of a G+8 Story Residential Building with Fixed Base and Base Isolation

Analytical Comparison of a G+8 Story Residential Building with Fixed Base and Base Isolation

... of base isolation system is to rectify the response of the structure in order that the bottom will move below the structure while not transferring these motions into the ...

6

Cieszewski

Cieszewski

... Historically, there were various other approaches at- tempting to solve this problem, most of which were de- veloped for site-dependent-height-age models, and they were evolving over time throughout the world. The sim- ...

12

Evaluation of Seismic Performance of Re-entrant Cornered Buildings with Base Isolators

Evaluation of Seismic Performance of Re-entrant Cornered Buildings with Base Isolators

... the base is negligible whereas the base isolated models have a considerable value of displacement at the ...the fixed base buildings have less drift value at the base level, then ...

6

Floor Response Spectra of Three-Dimensionally Base-Isolated Nuclear Power Plant Considering Soil-Structure Interaction Effect

Floor Response Spectra of Three-Dimensionally Base-Isolated Nuclear Power Plant Considering Soil-Structure Interaction Effect

... of base isolation technique applied on nuclear power plants (NPP) shall be examined by considering the soil structure interaction (SSI) because current NPP seismic design codes allow foundation soil much softer ...

8

A Study on Seismic Performance of Reinforced Concrete Frame with Lead Rubber Bearing Base Isolation System

A Study on Seismic Performance of Reinforced Concrete Frame with Lead Rubber Bearing Base Isolation System

... like base isolation system and X-bracings was carried out using ETBS ...maximum base shear were found out to find the effect of LRB used for the base isolation ...with fixed base, X ...

8

Responses of Building Base Isolated With High Damping Rubber Bearings

Responses of Building Base Isolated With High Damping Rubber Bearings

... design base-isolated buildings using ...the fixed-base building are ...the base-isolated building under earthquakes type-I and type-II, ...the base shear forces of the ...

6

Seismic Analysis of Asymmetric Multi Storied Frame Shear Wall Building Including Soil Structure Interaction

Seismic Analysis of Asymmetric Multi Storied Frame Shear Wall Building Including Soil Structure Interaction

... This research paper deals with comparative study of behavior of structure frames with three geometrical plan configurations and different positions of shear walls for each configuration. This study is attempted in ...

5

Seismic Response of Electrical Equipment in Nuclear Power Plants

Seismic Response of Electrical Equipment in Nuclear Power Plants

... While the building model is linear-elastic in all cases, different nonlinear models are used to represent the cabinet. The specific nonlinear models considered in this study are described earlier in section 3.1. A total ...

70

Soil Structure Interaction Effects on Seismic Performance of Multi Story RC Buildings with and without Shear Wall Soil Structure Interaction Effects on Seismic Performance of Multi Story RC Buildings with and without Shear Wall

Soil Structure Interaction Effects on Seismic Performance of Multi Story RC Buildings with and without Shear Wall Soil Structure Interaction Effects on Seismic Performance of Multi Story RC Buildings with and without Shear Wall

... the base of foundation neglecting the flexibility of the foundation, the compressibility of soil mass and consequently the effect of foundation settlement on further redistribution of bending moment and shear ...

12

Seismic Analysis of RC Structures using Base Isolation Technique

Seismic Analysis of RC Structures using Base Isolation Technique

... the base increases the flexibility of the building ...is fixed base and the second one is base ...of base isolation ...to fixed base ...

8