• No results found

Heat and Cooling

Experimental Analysis of Heat Transfer Behavior inside Heat Pipe Integrated with Cooling Plates

Experimental Analysis of Heat Transfer Behavior inside Heat Pipe Integrated with Cooling Plates

... the cooling apparatus while the heat pipe is immersed into the water tank for heat flux visualiza- tion ...The heat pipe transferred the heat into the wa- ter and changed the density ...

6

REVIEW OF COMPARATIVE STUDY AND ANALYSIS OF HEAT SINK FOR FAN LESS COOLING

REVIEW OF COMPARATIVE STUDY AND ANALYSIS OF HEAT SINK FOR FAN LESS COOLING

... area heat transfer coefficient (usually by increase fluid velocity, such as adding fans, pumps, ...a heat sink is a metal device with many ...the heat sink and whatever it is in direct thermal ...

6

Comparison on the effect of regenerative and film cooling in the heat transfer characteristics of semi cryogenic thrust chamber having rectangular cooling channels by using cfd and numerical analysis

Comparison on the effect of regenerative and film cooling in the heat transfer characteristics of semi cryogenic thrust chamber having rectangular cooling channels by using cfd and numerical analysis

... (height/width) cooling was applied, number of coolant ...curvature heat transfer enhancement in uniformly heated rectangular cooling ...of cooling in rocket ...conjugate heat transfer ...

8

Analysis of characteristic heat pipe as an efficient cooling heat transfer device

Analysis of characteristic heat pipe as an efficient cooling heat transfer device

... Furthermore, there is also another sample of the investigation of thermosyphon that are used in the application of solar water heater systems. But, in the investigation, the important parameters used such as the time ...

42

NUMERICAL INVESTIGATION OF FILM COOLING WITH CHEMICAL HEAT SINK

NUMERICAL INVESTIGATION OF FILM COOLING WITH CHEMICAL HEAT SINK

... Film Cooling Effectiveness on the Bottom Surface Figure 5 shows the contours of film cooling effectiveness on the bottom surface of the mainstream ...film cooling effectiveness are spanwise spreading ...

6

Experimental Study on Heat Transfer and Flow Characteristics of Air Cooling through Cross-flow Microchannel Heat Exchanger

Experimental Study on Heat Transfer and Flow Characteristics of Air Cooling through Cross-flow Microchannel Heat Exchanger

... line heat exchangers. The advantages of proposed microchannel heat exchangers were: a) compactness ...c) cooling capacity and COP increasing about 5% and 8% respectively under high vehicle ...& ...

136

Heat Compressor for Adsorption Cooling

Heat Compressor for Adsorption Cooling

... adsorption cooling processes, the engineer faces the problem o f inefficient heat and mass transfer in the heat ...specific cooling power o f the device, which deter­ mines its size or the ...

13

Study of Heat Pipe Cooling in A Machining Process

Study of Heat Pipe Cooling in A Machining Process

... Copyright to IJIRSET DOI: 10.15680/IJIRSET.2015.0404162 2275 evaporation temperature of working fluid, the working fluid will be evaporated. That causes the pressure difference between evaporator section and condensation ...

8

Design and Optimization of a Closed Two Loop Thermal Management Configuration for PEM Fuel Cell Using Heat Transfer Modules - Volume 3 Number 4 (Aug. 2012) - IJCEA

Design and Optimization of a Closed Two Loop Thermal Management Configuration for PEM Fuel Cell Using Heat Transfer Modules - Volume 3 Number 4 (Aug. 2012) - IJCEA

... removing heat from a fuel cell stack are further required to be cooled to ensure that the coolant is maintained at desired operating ...various cooling apparatus for cooling the coolant flowing ...

6

Design and Fabrication of a Peltier Operated Portable Air Cooling System

Design and Fabrication of a Peltier Operated Portable Air Cooling System

... and cooling of ...the heat exchanger where it absorbs heat from the air and flows back into the ...rejecting heat to the water air is cooled and passed into the ...

5

Exergy Analysis of Vapour and Sorption Cooling Processes

Exergy Analysis of Vapour and Sorption Cooling Processes

... a cooling device is heat output from the cooled system, which is at a lower temperature level than its ...that heat is transferred spontaneously only from a higher to a lower temperature ...of ...

10

REVIEW ON PORTABLE SOLAR THERMOELECTRIC REFRIGERATOR CUM AIR COOLER

REVIEW ON PORTABLE SOLAR THERMOELECTRIC REFRIGERATOR CUM AIR COOLER

... extracting heat from a substance using a heat exchanger. Space cooling is the same phenomenon as refrigeration, though heat is extracted from a defined space, to ensure that the temperature in ...

15

Design and Modal Analysis of Power Plant Cooling Towers

Design and Modal Analysis of Power Plant Cooling Towers

... Industrial cooling towers for a power plant Industrial cooling towers can be used to remove heat from various sources such as machinery or heated process ...industrial cooling towers is to ...

15

Experimental Investigation of Thermal Performance of PCM Based Heat Sinks of Different Fin Configurations and using Different Phase Change Materials Matrix

Experimental Investigation of Thermal Performance of PCM Based Heat Sinks of Different Fin Configurations and using Different Phase Change Materials Matrix

... the heat sink base temperature increases slowly to reach a peak value of 72°C at the end of heating stage, while that with PCM with Cu particle it increases at a rapidly to reach a lower value than that of the ...

6

Experimental and simulation study on the effect of geometrical and flow parameters for combined hole film cooling

Experimental and simulation study on the effect of geometrical and flow parameters for combined hole film cooling

... compression, heat addition, expansion and heat ...the heat addition process through converting the chemical energy of the fuels to flow energy of the combustion ...

45

Cataract Detection

Cataract Detection

... a heat transfer standpoint, a cooling tower’s performance while cooling a given quantity of water is influenced only by the wet bulb temperature of the entering ...a cooling tower as indicated ...

6

Design and Implementation of Geothermal Systems for Heating and Air Conditioning

Design and Implementation of Geothermal Systems for Heating and Air Conditioning

... Cumulative annual energy load is the change in the ground temperature over many years. If the building has a net heat gain or a net heat loss, the ground temperature will change. This is referred to as a ...

6

Energy Generation from Peltier Module by Utilizing Heat

Energy Generation from Peltier Module by Utilizing Heat

... the cooling source which can be a heat sink and cooling fan or metal tray containing cooling source and they are fitted inside a wooden ...the heat and protect the Peltier module from ...

5

A Dynamic Model for the Control of a Room’s Temperature by Means of Ceiling Cooling

A Dynamic Model for the Control of a Room’s Temperature by Means of Ceiling Cooling

... the heat load, are the temperature changes on the exterior wall surface j, which at the same time influence temperature changes on the interior wall surface j, and vice ...the heat fluxes for all the walls ...

5

A Review on Potential of Indirect Evaporative Cooling System

A Review on Potential of Indirect Evaporative Cooling System

... cycle heat and mass ...material heat conductivity have a very little impact on effectiveness of heat ...for heat conductivity between 0.1 to 100 W/m.K and found that heat flux has been ...

6

Show all 10000 documents...

Related subjects