• No results found

power harmonics control techniques

An Insight to Harmonic Suppression Techniques with Power Filters in Power Electronics

An Insight to Harmonic Suppression Techniques with Power Filters in Power Electronics

... active power filter is not a new arena in the research ...various techniques of active power filter for harmonic ...active power filter was published by Won [5] where the authors have ...

9

Index Terms: Multi-Level Inverter, Static Synchronous Compensator (STATCOM), Fault Detection and Provide Active and Reactive Power Compensation Technique.

Index Terms: Multi-Level Inverter, Static Synchronous Compensator (STATCOM), Fault Detection and Provide Active and Reactive Power Compensation Technique.

... advanced power electronic components are developed by the FACTS controlled ...the power system; 2) it operated under low voltages then corresponding the voltage stress in the STATCOM is also minimized; 3) ...

7

A Novel Method of Power Flow Control for the Compensation of Harmonics and Unbalanced Currents in Electric Railway Systems

A Novel Method of Power Flow Control for the Compensation of Harmonics and Unbalanced Currents in Electric Railway Systems

... The power range for the railroad application in this paper is around 10 MVA, and its implementation using multilevel converters have several ...modulation techniques, reported in the literature with several ...

10

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

... the power quality due to variable nature of wind. Power quality directly deals with the quality of voltage ...the power quality such as voltage sag, swell, harmonics flicker ...etc. ...

8

Elimination of harmonics in power system by the combination of passive and active filter with p q control technique

Elimination of harmonics in power system by the combination of passive and active filter with p q control technique

... Other techniques for the rating reduction of active have been e basis of a combination of active filter and passive elements such as capacitors and reactors (Majid Pakdel 2007; Akagi et ...eliminates ...

6

Control Of Upqc Converters Using Sliding Mode Pwm And Fuzzy Logic Based Compensation

Control Of Upqc Converters Using Sliding Mode Pwm And Fuzzy Logic Based Compensation

... to control active and reactive power problems where shunt converter mitigates harmonics & unbalances in load side for smooth waveforms & series converter was compensate for voltage variations ...

11

Mitigation of Harmonics Using Active Power Filters Based on Hysteresis Current Control

Mitigation of Harmonics Using Active Power Filters Based on Hysteresis Current Control

... current control strategy is of strict importance as the capacitor voltage changes continuously to the changing load ...current control techniques are used of which the adaptive hysteresis current ...

9

A Novel to Reduce Harmonics using Conventional Control of Active Shunt Power Filter

A Novel to Reduce Harmonics using Conventional Control of Active Shunt Power Filter

... of Harmonics in the Power System and steps to reduce the effects of ...with power quality and creates several disturbances to the Power ...reduction techniques to improve the ...

6

Performance of shunt hybrid compensator 
		for power quality improvement using simple control strategy

Performance of shunt hybrid compensator for power quality improvement using simple control strategy

... The harmonics present in the supply system have been reduced by using various types of power ...of harmonics but they require a current transformer and power semiconductor devices to withstand ...

9

Average Current Mode Control Technique Applied To Boost Converter For Power Factor Improvement And Thd Reduction

Average Current Mode Control Technique Applied To Boost Converter For Power Factor Improvement And Thd Reduction

... the power factor. So PFC techniques are used. Various power factor correction (PFC) techniques are employed to overcome these power quality problems out of which the boost converter ...

9

Harmonics Detection and Measurement in Power System

Harmonics Detection and Measurement in Power System

... A inventive system is presented and which is made from a combination of the ARM9 chip and virtual instrument methodology. It is designed for measurement of real-time harmonics [7]. Frequency is a significant ...

10

Ann Based Control Scheme for Hybrid Shunt Filter

Ann Based Control Scheme for Hybrid Shunt Filter

... ACTIVE POWER FILTER The hybrid active power filter is nothing but the series combination of active power filter and the passive ...The harmonics in the power system can be removed in ...

5

Improvement of Power Quality by Reduction of Harmonics

Improvement of Power Quality by Reduction of Harmonics

... The Fig 8 and 9 shows the percentage of total harmonic distortion before and after connecting filter. The percentage is very much reduced after connecting filter. It reduces from 23% to 5%. This shows that experimentally ...

8

Improvement of Power Quality by Reduction of Harmonics

Improvement of Power Quality by Reduction of Harmonics

... ABSTRACT: Harmonics is basically considered as major quandary in power ...improves power quality by the use of smaller and lighter electrical components, they are the source of ...and power is ...

7

Active Current Harmonics Reduction Control for Power Factor Correction in IPMSM Drive System

Active Current Harmonics Reduction Control for Power Factor Correction in IPMSM Drive System

... ‘Static’ power factor correction capacitors can be used with soft starters provided they are installed on the input side of the soft starter and switched via a dedicated contactor only after the motor has reached ...

13

Improved Active Power Filter for Renewable Power Generation Systems

Improved Active Power Filter for Renewable Power Generation Systems

... Where the value of THD (L) includes the maximum compensable harmonic current, defined as double the sampling frequency fs. The frequency of the maximum current harmonic component that can be compensated is equal to one ...

6

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

... new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters ...instantaneous power from its average ...the control ...

6

A New Power Quality Improvement In Single Phase Active Devices For Electrified Transportation

A New Power Quality Improvement In Single Phase Active Devices For Electrified Transportation

... isolation transformer and promotes industrial application for filtering purposes. The setup has shown great ability to perform requested compensating tasks for the correction of current and voltage distortions, PF ...

8

Simulation Of A 3-, 2-Level Inverter With A Discrete 3- Pwm Generator To Reduce The Harmonics And Improve The Power Quality

Simulation Of A 3-, 2-Level Inverter With A Discrete 3- Pwm Generator To Reduce The Harmonics And Improve The Power Quality

... many power projects from Conception stage to Commissioning stage at Goa, driven by the passion towards Teaching became an Engineering Teacher, worked in various capacities from Assistant Professor to Dean At ...

9

Power Quality Improvement in Solar by using Fuzzy Logic Controller

Power Quality Improvement in Solar by using Fuzzy Logic Controller

... the power balance between the grid, inverter ,and the load is achieved as the capacitor compensate instantaneously the difference between the grid and the load ...to control the ...

6

Show all 10000 documents...