• No results found

vector network analyzer measurements

Frequently Asked Questions about Vector Network Analyzer ZVR

Frequently Asked Questions about Vector Network Analyzer ZVR

... Compared with other calibration techniques, the TNA technique is the least demanding with regard to having to know the characteristics of the calibration standards. However, a few charac- teristics of the standards have ...

11

HP 8753E RF Vector Network Analyzer

HP 8753E RF Vector Network Analyzer

... SAW device measurements Completely characterize surface acoustic wave (SAW) devices with high-resolution return loss, insertion loss, and group-delay measurements. Measure passband ripple with 0.001-dB ...

10

Comparison of Open-Ended Coax and TDR sensors for the measurement of soil dielectric permittivity in microwave frequencies

Comparison of Open-Ended Coax and TDR sensors for the measurement of soil dielectric permittivity in microwave frequencies

... The measurements were performed using a TDR system working with a 20 ps rise-time step pulse and a Vector Network Analyzer (VNA) operating in the frequency range from 20 kHz to 8 ...

8

Obstacle-based self-calibration techniques for the determination of the permittivity of liquids

Obstacle-based self-calibration techniques for the determination of the permittivity of liquids

... a vector network analyzer, different methods like the line-network- method and the reflective method are ...obstacle network within a measurement cell filled with the dielectric ...the ...

7

CHARACTERIZATION OF X-BAND MICROWAVE COMPONENTS USING VECTOR NETWORK ANALYZER E5071C

CHARACTERIZATION OF X-BAND MICROWAVE COMPONENTS USING VECTOR NETWORK ANALYZER E5071C

... X -band microwave components are very important for measurements don in laboratories, research and development side. We have different types of microwave components among them some of the important components ...

8

Remote control of the ROHDE&SCHWARZ Vector Network Analyzer

Remote control of the ROHDE&SCHWARZ Vector Network Analyzer

... There are several motivations for remote controlling of those devices, but the most important is the possibility of fetching measurement data by the remote computer and use other program packages such as MATLAB, Octave, ...

5

Low-cost Vector Network Analyzer for Biomedical Applications

Low-cost Vector Network Analyzer for Biomedical Applications

... The microstrip UWB antennas have considerable attention for biomedical applications (e.g. breast cancer detection, brain cancer detection, health monitoring, etc.) due to their mannumber of advantages such as low cost, ...

5

Calibration of vector network analyzers on the basis of the LRR-method

Calibration of vector network analyzers on the basis of the LRR-method

... Abstract. The LRR method for the calibration of vector net- work analyzers is presented. This method belongs to the self calibration procedures where the calibration circuits might be partly unknown. The LRR ...

5

Best Practice Guide for Planar S-Parameter Measurements using Vector Network Analysers

Best Practice Guide for Planar S-Parameter Measurements using Vector Network Analysers

... a vector network analyzer interfaced with an interferometric setup built up with a hybrid coupler associated to low noise ...matching network in the range 1-18 GHz built up with a power ...

65

Determination of the Complex Permittivity Values of Planar Dielectric Substrates by Means of a Multifrequency PSO-Based Technique

Determination of the Complex Permittivity Values of Planar Dielectric Substrates by Means of a Multifrequency PSO-Based Technique

... impedance measurements performed on a section of a microstrip transmission line built on the planar dielectric substrate under test, the proposed technique formulates the reconstruction prob- lem in terms of an ...

9

Measurement consistency and the effect of ground planes on common mode crosstalk

Measurement consistency and the effect of ground planes on common mode crosstalk

... a Vector Network Analyzer (VNA) using Baluns, balanced measurement using Baluns with an EMI Test Receiver (transceiver), balanced measurement using Baluns with a Spectrum Analyzer (SA) and ...

8

An Analysis of Wireless Network ARP Spoofing

An Analysis of Wireless Network ARP Spoofing

... of Network Appliance was looking for something better than tcpview, so he started applying patches and contributing dissectors to ...a network packet analyzer. A network packet analyzer ...

6

Network Delay: Network Analyzer and 
                      Opnet Simulation Tool

Network Delay: Network Analyzer and Opnet Simulation Tool

... of network delay using heterogeneous ...and analyzer features. OPNET has originally been developed for network simulation and it is fully usable as a robust and reliability simulation tool with ...

7

The Importance Of Corneal  Biomechanical Properties In Ocular Hypertension And Glaucoma

The Importance Of Corneal Biomechanical Properties In Ocular Hypertension And Glaucoma

... 107 eyes of the 138 examined fufilled the inclusion criteria and were included into the study being devided into 3 groups: 52 eyes in the first group, 33 eyes in the second group and 22 in the third group. For the first ...

5

CN-100 Network Analyzer

CN-100 Network Analyzer

... active network VPI/VCI up to 16 million Bandwidth Utilization, rate/peak rate, Cells/bits per second Extensive Filter and Trigger Capabilities: 32 Header Filters, 2 ...

7

Continuous measurements of atmospheric water vapour isotopes in western Siberia (Kourovka)

Continuous measurements of atmospheric water vapour isotopes in western Siberia (Kourovka)

... An illustration of our calibration set-up is shown on Fig. 2. The liquid standard is drawn from container by syringe pump of the SDM and transferred via capillary line into the Picarro injection head (C0105) of the ...

14

W-Band Microstrip-to-Waveguide Transition Using via Fences

W-Band Microstrip-to-Waveguide Transition Using via Fences

... The fabricated transition is measured in a back-to-back configuration using an HP8510C vector network analyzer. In W-band, the measured insertion loss is about 3.2 dB, which includes los[r] ...

10

Agilent Spectrum and Signal Analyzer Measurements and Noise

Agilent Spectrum and Signal Analyzer Measurements and Noise

... In a second example, we are measuring noise in an adja- cent channel in which the noise spectrum is flat. Let’s use a 600-point analyzer with a span of 100 kHz and a channel BW of 25 kHz, giving 150 points in our ...

31

Small Size Active Antenna for VHF Band

Small Size Active Antenna for VHF Band

... ABSTRACT: In this paper an active antenna is designed at 200 MHz frequency. Active antenna is a combination of a active circuit and passive monopole antenna. Active circuit is consists of an active device, impedance ...

5

Study on Small Signal Modeling of GaN HEMT Devices

Study on Small Signal Modeling of GaN HEMT Devices

... uses vector network analyzer (VNA) to measure S parameters under different biases at different frequency points, and uses the distributed extraction method to extract the parasitic parameters and ...

5

Show all 10000 documents...

Related subjects