• No results found

[PDF] Top 20 Application of EL CID to salient pole electrical machines

Has 10000 "Application of EL CID to salient pole electrical machines" found on our website. Below are the top 20 most common "Application of EL CID to salient pole electrical machines".

Application of EL CID to salient pole electrical machines

Application of EL CID to salient pole electrical machines

... the EL CID traces arising when this form of excitation was applied, it is necessary to identify the significance of variations exhibited in any ...an EL CID signal would be a perfectly ... See full document

200

Componential coding in the condition monitoring of electrical machines Part 2: application to a conventional machine and a novel machine

Componential coding in the condition monitoring of electrical machines Part 2: application to a conventional machine and a novel machine

... Figure 5 provides an example segment from one of the four channels in each case. Initial visual examination of the data-sets revealed that three separate anomalous conditions were contained within them with respect to ... See full document

15

Analysis of salient pole synchronous generators operating in single phase condition

Analysis of salient pole synchronous generators operating in single phase condition

... in electrical engineering from the University of Bologna, Bologna, Italy, in ...of Electrical Engineering, University of Bologna, first as a recipient of a Fellowship of the National Research Council, then ... See full document

6

A fast method for modelling skew and its effects in salient pole synchronous generators

A fast method for modelling skew and its effects in salient pole synchronous generators

... skewed electrical machines can lead to inaccuracies in predicting the performance, especially when these are equipped with short- circuited ...one pole are ... See full document

10

Sensitivity analysis for performance and power density improvements in salient pole synchronous generators

Sensitivity analysis for performance and power density improvements in salient pole synchronous generators

... The geometry of the stator slots and rotor poles can also affect the performance of electrical machines. The flux lines distribution can be modified and the hysteresis and eddy current losses can be ... See full document

6

Phasor diagram analysis for non salient 
		pole synchronous generator

Phasor diagram analysis for non salient pole synchronous generator

... the electrical power has been increased tremendously in recent ...of electrical lines interconnection the generating power system in to support high demand of ...of pole have been ... See full document

6

Short term duty electrical machines

Short term duty electrical machines

... Given the performance requirement of high power-density, the initial design analysis indicates that both the 60-slot/10- pole design and 24-slot/16-pole design can be selected for the application. ... See full document

6

Salient Pole Synchronous Generator Optimization by Combined Application of Slot Skew and Damper Winding Pitch Methods

Salient Pole Synchronous Generator Optimization by Combined Application of Slot Skew and Damper Winding Pitch Methods

... Modern electrical generators need to satisfy different requirements among which the most prominent ones are voltage waveform quality, noise and vibration levels which are defined in tenders and measured on ... See full document

10

A Simple Pattern Recognition Approach for Monitoring Incipient Stator Faults in Salient-Pole Synchronous Generators

A Simple Pattern Recognition Approach for Monitoring Incipient Stator Faults in Salient-Pole Synchronous Generators

... The majority of electrical machines can be seen as RL circuits described using Eq. (1). The methodology used in this paper considers a linear model for the synchronous machine, whereas speed remains ... See full document

16

A Review on Modelling of the Maximum Lagging Current Test Method of Salient Pole Synchronous Machines

A Review on Modelling of the Maximum Lagging Current Test Method of Salient Pole Synchronous Machines

... of salient pole synchronous ...the pole-slipping commences at load angle equal to 45 degrees or by a better language at 225 instead of zero which is the common opinion of almost all the previously ... See full document

10

Improved transient simulation of salient-pole synchronous generators with internal and ground faults in the stator winding

Improved transient simulation of salient-pole synchronous generators with internal and ground faults in the stator winding

... He has held academic posts at Brunel University, Uxbridge, U.K., and Southampton University, and spent a period in industry with NEI Parsons Ltd. working on electromagnetic problems related to turbo-generators. He is ... See full document

8

Electrical transients in permanent magnet synchronous machines.

Electrical transients in permanent magnet synchronous machines.

... synchronous machines, since the effective air-gap length on the quadrature axis is small, the saturation in this axis is ...these machines, usually the impact of the saturation, especially the effect of the ... See full document

91

Vector Diagram Correlation Of Leading And Lagging Power Factor In Salient Pole Synchronous Machine

Vector Diagram Correlation Of Leading And Lagging Power Factor In Salient Pole Synchronous Machine

... Salient pole synchronous generator has a wide range of vector diagram construction, namely: (i) Vector diagram at active-capacitive load, (ii) at active-inductive load, (iii) at unsaturated regime, (iv) at ... See full document

9

TWO-DIMENSIONAL ANALYTICAL MAGNETIC FIELD CALCULATIONS FOR DOUBLY-SALIENT MACHINES

TWO-DIMENSIONAL ANALYTICAL MAGNETIC FIELD CALCULATIONS FOR DOUBLY-SALIENT MACHINES

... brushless machines with surface inset magnets have a doubly-salient structure where the stator slots house the windings and the magnets are normally placed between two adjacent rotor ...the machines ... See full document

25

Energy Auditing and Efficiency Improvement on Electrical Machines

Energy Auditing and Efficiency Improvement on Electrical Machines

... Copyright to IJAREEIE DOI:10.15662/IJAREEIE.2016.0503089 1604 A step-up of this magnitude is unlikely to materialize with a traditional approach. A new radically approach of Energy Audit and conservation at all levels of ... See full document

5

A hybrid analytical numerical approach for the analysis of salient pole synchronous generators with a symmetrical damper cage

A hybrid analytical numerical approach for the analysis of salient pole synchronous generators with a symmetrical damper cage

... particular salient-pole SG, when operating in linear condition, by implementing a mixed analytical-numerical model that turns out much faster than the classic FE ... See full document

8

Inadequacy of 1D, 2D and 3D Resistivity Inverse Modelling in the Presence of Electrical Anisotropy

Inadequacy of 1D, 2D and 3D Resistivity Inverse Modelling in the Presence of Electrical Anisotropy

... independent, was interpreted by using 1D inversion with fixing depth to the boundaries in the three layer 1D anisotropic model. In order to interpret this square array mean geometric resistivity curve by using 1D ... See full document

15

Time-Stepping Finite-Element Analysis of Dynamic Eccentricity Fault in a Three-Phase Salient Pole Synchronous Generator

Time-Stepping Finite-Element Analysis of Dynamic Eccentricity Fault in a Three-Phase Salient Pole Synchronous Generator

... It was observed from the two-dimensional TSFEM, moderate degree of DE fault has no significant effect on the performance of a salient pole synchronous generator. The effect of DE fault in the generator at ... See full document

22

A Simple Analytic Method to Model and Detect Non-Uniform Air-Gaps in Synchronous Generators

A Simple Analytic Method to Model and Detect Non-Uniform Air-Gaps in Synchronous Generators

... The results are not limited to the case of skewed salient-pole rotors. The skewing of rotor and non- uniformity of air-gap affects harmonics differently. For the proposed case study, skewing has an impact ... See full document

7

APPLICATION OF NUMERICAL SOFTWARES IN ELECTRICAL MACHINES MODELLING

APPLICATION OF NUMERICAL SOFTWARES IN ELECTRICAL MACHINES MODELLING

... For a physical machine where the rotor speed changes with time, analytical solution for equation (3) is not possible. Therefore, and efficient and a suitable numerical software [r] ... See full document

7

Show all 10000 documents...