• No results found

[PDF] Top 20 Comparative Evaluation of the Bruker Biotyper and Vitek MS Matrix Assisted Laser Desorption Ionization–Time Of Flight (MALDI TOF) Mass Spectrometry Systems for Identification of Yeasts of Medical Importance

Has 10000 "Comparative Evaluation of the Bruker Biotyper and Vitek MS Matrix Assisted Laser Desorption Ionization–Time Of Flight (MALDI TOF) Mass Spectrometry Systems for Identification of Yeasts of Medical Importance" found on our website. Below are the top 20 most common "Comparative Evaluation of the Bruker Biotyper and Vitek MS Matrix Assisted Laser Desorption Ionization–Time Of Flight (MALDI TOF) Mass Spectrometry Systems for Identification of Yeasts of Medical Importance".

Comparative Evaluation of the Bruker Biotyper and Vitek MS Matrix Assisted Laser Desorption Ionization–Time Of Flight (MALDI TOF) Mass Spectrometry Systems for Identification of Yeasts of Medical Importance

Comparative Evaluation of the Bruker Biotyper and Vitek MS Matrix Assisted Laser Desorption Ionization–Time Of Flight (MALDI TOF) Mass Spectrometry Systems for Identification of Yeasts of Medical Importance

... for MS iden- tification, each isolate was cultured on Sabouraud dextrose (Kima, Padua, Italy) agar and incubated for 24 h at ...of yeasts was suspended in one volume of ... See full document

5

Evaluation of the Bruker Biotyper Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Blood Isolates of Acinetobacter Species

Evaluation of the Bruker Biotyper Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Blood Isolates of Acinetobacter Species

... available matrix-as- sisted laser desorption ionizationtime of flight mass spectrome- try (MALDI-TOF MS) systems are rapidly emerging novel ... See full document

6

Comparison of the Vitek MS and Bruker Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Systems for Identification of Rhodococcus equi and Dietzia spp

Comparison of the Vitek MS and Bruker Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Systems for Identification of Rhodococcus equi and Dietzia spp

... problematic. Matrix-assisted laser desorption ionizationtime of flight mass spec- trometry (MALDI-TOF MS) is a fast, reliable, and cost-effective ... See full document

6

Dermatophyte Identification Using Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

Dermatophyte Identification Using Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

... the Bruker Biotyper matrix-assisted laser desorption ionizationtime of flight (MALDI- TOF) mass spectrometer (MS) for the ... See full document

5

Evaluation of the Andromas Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Aerobically Growing Gram Positive Bacilli

Evaluation of the Andromas Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Aerobically Growing Gram Positive Bacilli

... Each MALDI-TOF MS identification system has its own spec- ificities, including the hardware itself (the mass spectrometer), the way the database was built, and the algorithms used to ... See full document

6

Successful Identification of Clinical Dermatophyte and Neoscytalidium Species by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

Successful Identification of Clinical Dermatophyte and Neoscytalidium Species by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

... Pro MS system (Applied Biosystems, Darmstadt, Germany) and the SARAMIS spectral database (Ag- nosTec, Potsdam, Germany), Erhard and coworkers succeeded in identifying five dermatophyte species ...the Bruker ... See full document

5

Rapid Identification of Positive Blood Cultures by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Using Prewarmed Agar Plates

Rapid Identification of Positive Blood Cultures by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Using Prewarmed Agar Plates

... Diagnostic Systems, Sparks, MD) were prewarmed at 37°C for 1 ...our MALDI-TOF MS system (Vitek MS, bio- Mérieux, Durham, NC), as per the manufacturer, which was con- firmed by ... See full document

5

Identification of Medically Relevant Species of Arthroconidial Yeasts by Use of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

Identification of Medically Relevant Species of Arthroconidial Yeasts by Use of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

... by MALDI-TOF MS analysis and usually had log score values of ...the MALDI-TOF MS identification might be considered a minor ...Reliable identification of ...the ... See full document

10

A case report of a cystic fibrosis patient with repeated isolation of Trichosporon mycotoxinivorans identified by a novel short extraction method

A case report of a cystic fibrosis patient with repeated isolation of Trichosporon mycotoxinivorans identified by a novel short extraction method

... 2012, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) was performed for the first ... See full document

5

Comparison of Bruker Biotyper Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometer to BD Phoenix Automated Microbiology System for Identification of Gram Negative Bacilli

Comparison of Bruker Biotyper Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometer to BD Phoenix Automated Microbiology System for Identification of Gram Negative Bacilli

... on MALDI-TOF MS analyses of specific bacterial genera (9, 18, 21, 23, 25, ...bacterial identification in the clinical laboratory (1, 2, 5, 22, ...of MALDI-TOF MS to ... See full document

6

Identification of a Variety of Staphylococcus Species by Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry

Identification of a Variety of Staphylococcus Species by Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry

... by MALDI Biotyper 2.0 software (Bruker Daltonique) with default ...from MALDI-TOF MS measurement to identification was per- formed automatically without any user ... See full document

5

Optimization of Routine Identification of Clinically Relevant Gram Negative Bacteria by Use of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry and the Bruker Biotyper

Optimization of Routine Identification of Clinically Relevant Gram Negative Bacteria by Use of Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry and the Bruker Biotyper

... Matrix-assisted laser desorption ionizationtime of flight mass spectrometry (MALDI-TOF MS) might complement and one day replace ... See full document

9

Comparison of the Microflex LT and Vitek MS Systems for Routine Identification of Bacteria by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

Comparison of the Microflex LT and Vitek MS Systems for Routine Identification of Bacteria by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

... MALDI-TOF MS technology is a powerful tool that can be used in routine laboratories for the diagnosis of enteric ...pathogen identification itself, the limitations of MALDI-TOF ... See full document

13

Comparison of Direct Colony Method versus Extraction Method for Identification of Gram Positive Cocci by Use of Bruker Biotyper Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

Comparison of Direct Colony Method versus Extraction Method for Identification of Gram Positive Cocci by Use of Bruker Biotyper Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

... evaluated Bruker Biotyper (version 2.0) matrix-assisted laser desorption ionizationtime of flight (MALDI-TOF) mass spectrometry ... See full document

6

Evaluation of the Vitek MS Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Clinically Relevant Filamentous Fungi

Evaluation of the Vitek MS Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Clinically Relevant Filamentous Fungi

... by MALDI-TOF ...both MALDI-TOF MS and ...Accurate identification of this organism is important due to its decreased susceptibility to many antifungals, including some azoles, ... See full document

6

Comparison of the Bruker Biotyper and Vitek MS Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Systems for Identification of Mycobacteria Using Simplified Protein Extraction Protocols

Comparison of the Bruker Biotyper and Vitek MS Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Systems for Identification of Mycobacteria Using Simplified Protein Extraction Protocols

... of identification for M. fortuitum identified with the combined UW/ Bruker compared with the SARAMIS ...four time points tested with the former database, none of the ...85% identification rate ... See full document

9

Interlaboratory Comparison of Sample Preparation Methods, Database Expansions, and Cutoff Values for Identification of Yeasts by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Using a Yeast Test Panel

Interlaboratory Comparison of Sample Preparation Methods, Database Expansions, and Cutoff Values for Identification of Yeasts by Matrix Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Using a Yeast Test Panel

... using matrix-assisted laser desorption ionizationtime of flight mass spectrometry (MALDI-TOF MS) to determine the identification ... See full document

7

Helicobacter cinaedi bacteremia with cellulitis in a living donor kidney transplant recipient identified by matrix assisted laser desorption ionization time of flight mass spectrometry: a case report

Helicobacter cinaedi bacteremia with cellulitis in a living donor kidney transplant recipient identified by matrix assisted laser desorption ionization time of flight mass spectrometry: a case report

... by MALDI-TOF MS (Biotyper ver. 3.0 ® ; Bruker Corporation, ...The identification score was ...accurate identification of H. cinaedi (Fig. 2). Additional evaluation ... See full document

5

MALDI-TOF mass spectroscopy of yeasts and filamentous fungi for research and diagnostics in the agricultural value chain

MALDI-TOF mass spectroscopy of yeasts and filamentous fungi for research and diagnostics in the agricultural value chain

... Recently, MALDI-TOF MS has been employed to rap- idly and simultaneously detect and identify the Alter- naria mycotoxins alternariol, monomethyl ether, and tentoxin in cereal grains ...the ... See full document

12

Identification of Candida species isolated from vulvovaginitis in Mashhad, Iran by Use of MALDI-TOF MS

Identification of Candida species isolated from vulvovaginitis in Mashhad, Iran by Use of MALDI-TOF MS

... molecular identification tests for yeasts are based on a polymerase chain reaction amplification, followed by the sequencing of the internal transcribed spacer region and the D1/D2 domains of the large ... See full document

5

Show all 10000 documents...