• No results found

AC-side active filters

Improvement of Power Quality using Active Filters

Improvement of Power Quality using Active Filters

... L-C filters were used to reduce harmonics and capacitors were employed to improve the power factor of the ac loads, but they present several disadvantages, namely: they only filter the frequencies they were ...

6

Optimize Controlling of Active Filters Controlled by Pi Controller

Optimize Controlling of Active Filters Controlled by Pi Controller

... the AC mains as compare to traditional loads such as motors and resistive heating ...tuned active power filter for harmonic minimization and reactive power compensation of non-linear load under fast load ...

5

Improvement of Power Quality by Fuzzy Based Transformer less Active Power Filter

Improvement of Power Quality by Fuzzy Based Transformer less Active Power Filter

... input ac mains and the output load (sensitive loads) in the area of power line conditioning is very important in power electronics ...supplies, active filters, and hybrid filters ...

12

Performance and Control of a Hybrid Active Filter Enabled Interface of a HVDC Converter Station for 
Weak AC Systems.

Performance and Control of a Hybrid Active Filter Enabled Interface of a HVDC Converter Station for Weak AC Systems.

... CHAPTER 3 looks at the considerations to design a HVDC system including the LCC, transformer, and passive filters. The analysis of the LCC from [1] is used to design the parameters for the converter. The designed ...

109

Performance Evaluation of VSI Based Active Filter and Passive Filters

Performance Evaluation of VSI Based Active Filter and Passive Filters

... based active power filters to Non-linear load for improving power ...these filters. These filters can reduce harmonic in supply ...an AC supply it produces a quasi square waveform which ...

5

Inverter controller using synchronous generator mathematical model

Inverter controller using synchronous generator mathematical model

... drives, active filters and unified power flow controllers in power systems and uninterrupted power supplies to generate controllable frequency and AC voltage magnitudes using various pulse width ...

28

Enhancement of Quality in Power Systems With Active Power Filters

Enhancement of Quality in Power Systems With Active Power Filters

... Series active power filters operate mainly as a voltage regulator and as a harmonic isolator between the nonlinear load and the utility ...the ac supply and for low power applications and represents ...

10

Shunt active filters for power quality improvement

Shunt active filters for power quality improvement

... the active filtering for harmonic reduction and power factor ...shunt active filter consists of controllable voltage a and current source ...shunt active power filter acts as harmonic current source ...

5

Importance of Active Filters for Improvement of Power Quality

Importance of Active Filters for Improvement of Power Quality

... the ac side and two wires on the dc side. Active shunt AF’s are developed in the current-fed type ...configurations. Active shunt AF’s are also designed with three single-phase AF’s ...

8

Active Filters

Active Filters

... Abstract— Active power filter continues to attract considerable ...electronics. Active power filter technology is the most efficient way to compensate reactive power and cancel out low order harmonics ...

11

Application of Active Power Filters to compensate reactive power

Application of Active Power Filters to compensate reactive power

... as AC/DC converter, arc furnace, switching power supplies have been significantly growth in the power system and smart ...Passive filters are the first solution to eliminate these harmonics, however; they ...

7

Vol 3, No 9 (2015)

Vol 3, No 9 (2015)

... Current modulator is mainly used to provide the gate pulse to the active power filter (Inverter). There are many techniques used for giving the gating signals to PWM VSI such as sinusoidal PWM, triangular PWM, ...

6

The Investigation of Equivalent Harmonic Impedances of VSC-Based HVDC Systems

The Investigation of Equivalent Harmonic Impedances of VSC-Based HVDC Systems

... Fig. 6 shows the driving point impedance as seen from the Point of Common Coupling (PCC) and the VSC’s output terminal (A point) in both cases of PoS and NeG background harmonics. At the PCC point (Fig. 6(a) and Fig. ...

5

Comparative investigation of shunt active power filters in 25kv ac electrified systems

Comparative investigation of shunt active power filters in 25kv ac electrified systems

... This paper presents a comparative study on the SAPF applications to the AC electrified railway systems and proposes novel control algorithms. The comparative study on two SAPF configurations is demonstrated via a ...

10

International Journal of Scientific Research and Reviews A Review of Active Power Filters and Their Control Strategies

International Journal of Scientific Research and Reviews A Review of Active Power Filters and Their Control Strategies

... In addition, the harmonic currents produced by nonlinear loads can interact adversely with a wide range of power system equipment, most notably capacitors, transformers, and motors, causing additional losses, ...

13

Improving quality of power using try 
		converter unified power quality conditioner (T UPQC)

Improving quality of power using try converter unified power quality conditioner (T UPQC)

... injection. Such that the active power drawn from the utility which is maintained unity power factor. When the supply is balanced the phase voltages are equal. Figure-7 explains that in case of voltage sag how the ...

8

Reduction of Harmonics by Using Active and Passive Harmonics Filters

Reduction of Harmonics by Using Active and Passive Harmonics Filters

... Abstract: Harmonics Distortion problems counter many of the conventional rules of Electric power system design and operation that consider only the fundamental frequency. The engineer is faced with unfamiliar phenomena ...

9

EFFICIENCY IMPROVEMENT OF ELECTRIC VEHICLE BY USING ACTIVE FILTERS

EFFICIENCY IMPROVEMENT OF ELECTRIC VEHICLE BY USING ACTIVE FILTERS

... The MAIN bridges work at fundamental frequency (only two switching actions per cycle) and because they manage more than 98% of the power. The switching losses of the overall converter become very small. On the other ...

8

A Perception to Digital Control Schemes for Active Power Filters

A Perception to Digital Control Schemes for Active Power Filters

... eliminate them. Choudhary and Gaur [10] have discussed the control strategies towards active power filters exiting in the most recent times. The controlling techniques discussed by the author were signaling ...

13

Active Optical Lattice Filters

Active Optical Lattice Filters

... cation, detection and estimation, active noise cancellation, and embedded digital systems and processors. Dr. Panahi worked as a Research Scientist on the multidimensional and statistical signal processing at ...

10

Show all 10000 documents...

Related subjects