• No results found

active voltage-clamp circuit

Active absorption of Na+ and Cl  across the gill epithelium of the shore crab Carcinus maenas: voltage clamp and ion flux studies

Active absorption of Na+ and Cl across the gill epithelium of the shore crab Carcinus maenas: voltage clamp and ion flux studies

... short- circuit), these findings not only verify the presence of active NaCl absorption across shore crab gills but may also be used to measure active transport of Na + and Cl − and to relate ...

10

Active-Clamp Circuit to Achieve ZVS in Multioutput Fly back Converter

Active-Clamp Circuit to Achieve ZVS in Multioutput Fly back Converter

... an active clamp is added in multioutput fly-back converter to achieve soft switching (Zero voltage ...in voltage stress on main switch. To overcome this disadvantage an active ...

6

High Gain DC-DC Converter using Active Clamp Circuit (RESEARCH NOTE)

High Gain DC-DC Converter using Active Clamp Circuit (RESEARCH NOTE)

... the voltage across the switches can be verified from Figure ...required voltage gain of 10. As a result, the output voltage was 123 V which closely matches with the theoretical design and simulation ...

8

Design of Clamp Forward Converter Used in Computing Devices

Design of Clamp Forward Converter Used in Computing Devices

... B. ACTIVE-CLAMPING ZVS FORWARD CONVERTER Fig. 2 shows the circuit configuration of the adopted active-clamping ZVS forward ...standby voltage can be realized by adding an extra winding on the ...

5

Closed Loop Control of Transformer-Less Adaptable Voltage Quadrupler DC Boost Converter

Closed Loop Control of Transformer-Less Adaptable Voltage Quadrupler DC Boost Converter

... isolated voltage type converters are existing such as the phase shifted full bridge ...the circuit efficiency is degraded because of high output diode voltage stress than the output voltage in ...

11

Inherent Clamp Flyback-Buck Converter with Winding Cross-Coupled Inductors Zero Current Switching

Inherent Clamp Flyback-Buck Converter with Winding Cross-Coupled Inductors Zero Current Switching

... dual active clamped step-up DC-DC converter to obtain high power density, high efficiency with reduced voltage stress and negligible switching ...the voltage stress by sharing the output ...

11

Intracellular recording with low-power low-noise CMOS voltage and current clamp circuits

Intracellular recording with low-power low-noise CMOS voltage and current clamp circuits

... Layout has been done using the AMI 0.5 µm process and the chip will be fabricated in the coming months. Significant work still remains in prov- ing this design to be a viable intracellular recording option. Foremost ...

87

A State Space Modeling of Non Isolated Bidirectional DC DC Converter with Active Switch

A State Space Modeling of Non Isolated Bidirectional DC DC Converter with Active Switch

... LCD clamp with passive components eliminates the above problems by storing the leakage energy into a capacitor even the power switches is in OFF ...The active switch in the proposed topology reduc- es ...

11

High step up interleaved dc dc converter with coupled inductor

High step up interleaved dc dc converter with coupled inductor

... presented active-clamp circuit, based on single boost converter, can successfully reduce the voltage stress of the switches close to the low-level voltage stress offered by an ideal ...

6

A Novel High step-up dc–dc converter for Boosting Fuel Cell Voltage through the Three-Winding Coupled Inductor

A Novel High step-up dc–dc converter for Boosting Fuel Cell Voltage through the Three-Winding Coupled Inductor

... the active-clamp circuits can be inserted to achieve a zero voltage-switching (ZVS) soft- switching performance and to recycle the leakage ...and active-clamp circuits are proposed for ...

5

Implementation of Novel Control Strategies for Interleaved Flyback Inverter with Photovoltaic AC Module System

Implementation of Novel Control Strategies for Interleaved Flyback Inverter with Photovoltaic AC Module System

... an active clamp circuit is determined by calculating the voltage spike imposed at both terminals of the main ...the active clamp circuit can also be reduced according to ...

8

Parasitic Boost Circuit For Transformer Less Active Voltage Quality Regulator With Closed Loop Controller

Parasitic Boost Circuit For Transformer Less Active Voltage Quality Regulator With Closed Loop Controller

... grid voltage differs from its desired waveform, a missing voltage will be injected and filtered by the DySC through its half-bridge converter (V1, V2) and output filter (Lf, Cf) to maintain the load ...

9

Precision Active Bridge Circuit for Measuring Incremental Resistance with ANN Compensation of Excitation Voltage Variation

Precision Active Bridge Circuit for Measuring Incremental Resistance with ANN Compensation of Excitation Voltage Variation

... Resistive sensors are some of the most widely used sen- sors because of low cost, easy to fabricate, and interface with signal conditioning circuits. Some of the common physical parameters where resistive sensors used ...

8

Model predictive control for Active Bridge Active Clamp (ABAC) converter

Model predictive control for Active Bridge Active Clamp (ABAC) converter

... large voltage conversion ratios are required. However, in low voltage high power cases, the output current ripple is significant and large filtering capacitance is ...the Active-Bridge-Active- ...

6

Current Voltage Relations in the Isolated Giant Axon of the Cockroach Under Voltage Clamp Conditions

Current Voltage Relations in the Isolated Giant Axon of the Cockroach Under Voltage Clamp Conditions

... It will be seen that a transient membrane capacity current at the beginning of the voltage step is followed by an initial inward current I{ which changes smoothly into an outward delayed[r] ...

13

Voltage clamp simulations of cardiac 
		excitation: FPGA implementation

Voltage clamp simulations of cardiac excitation: FPGA implementation

... the voltage clamp experiment, a simulation approach of the voltage clamp is more preferred as it is easier and cost ...the voltage clamp method needs to be developed by real-time ...

9

CPT-cGMP Is A New Ligand of Epithelial Sodium Channels

CPT-cGMP Is A New Ligand of Epithelial Sodium Channels

... and voltage clamp techniques showed that 8-pCPT-cGMP increased the amiloride-sensitive short-circuit current across H441 cell monolayers and also increased heterologously expressed αβγδ-ENaC activity ...

8

Modeling CICR in rat ventricular myocytes: voltage clamp studies

Modeling CICR in rat ventricular myocytes: voltage clamp studies

... Our voltage clamp simulations have dealt with clamp voltages in the range -30 mV ≤ V ≤ 40 ...larger clamp voltages (40 mV ≤ V ≤ 60 mV) to explore the high voltage behavior of the ...

66

GLOBAL JOURNAL OF ADVANCED ENGINEERING TECHNOLOGIES AND SCIENCES COMPARISON OF MAXIMUM POWER POINT TRACKING ALGORITHMS FOR PV SYSTEM USING MATLAB/SIMULINK Ch Nayak Bhukya *1 , Abera Eshetu 2& Kalidas Gera3

GLOBAL JOURNAL OF ADVANCED ENGINEERING TECHNOLOGIES AND SCIENCES COMPARISON OF MAXIMUM POWER POINT TRACKING ALGORITHMS FOR PV SYSTEM USING MATLAB/SIMULINK Ch Nayak Bhukya *1 , Abera Eshetu 2& Kalidas Gera3

... open circuit voltage method was the simplest considering ease of implementation and number of sensors but its performance was least impressive with ...

14

High Efficiency Resonant Boost Converter for Photovoltaic Energy Harvesting

High Efficiency Resonant Boost Converter for Photovoltaic Energy Harvesting

... The work proposes a single-switch resonant boost converter which can be implemented in photovoltaic energy generation systems. Fig.1 shows the basic circuit diagram of proposed resonant converter. The converter ...

7

Show all 10000 documents...

Related subjects