• No results found

electron energy loss data

Automated background subtraction technique for electron energy-loss spectroscopy and application to semiconductor heterostructures

Automated background subtraction technique for electron energy-loss spectroscopy and application to semiconductor heterostructures

... more data points for modelling of the background and chemical shifts that could shift the edge onset by up to ~8eV are less prone to influence the background ...experimental energy-loss axis limit ...

25

High-resolution monochromated electron energy-loss spectroscopy of organic photovoltaic materials

High-resolution monochromated electron energy-loss spectroscopy of organic photovoltaic materials

... superior energy resolution of the Nion UltraSTEM 100 MC ÔHERMESÕ microscope (35 meV energy resolution in the beam conditions used here) improved the resolution of the peaks in the raw spectra and made it ...

23

Compositional analysis of InAs GaAs GaSb heterostructures by low loss electron energy loss spectroscopy

Compositional analysis of InAs GaAs GaSb heterostructures by low loss electron energy loss spectroscopy

... parallel electron energy loss spectrometer ...EELS data were acquired, from 0 to 60 eV, using a collection aperture with a semi-angle of 5 mrad and a convergence semi-angle of 24 ...an ...

6

EELS from organic crystalline materials

EELS from organic crystalline materials

... low electron fluences required to prevent irradiation damage in these samples, core loss spectra suffered from low signal to noise ratios (SNR) due to dominance of detector readout noise and dark current ...

5

Effect of annealing on the structure and magnetic properties of Co2FeAl0.5Si0.5 thin films on Ge(111)

Effect of annealing on the structure and magnetic properties of Co2FeAl0.5Si0.5 thin films on Ge(111)

... transmission electron microscopy (STEM) and electron energy loss spectroscopy (EELS) measurements reveal that the changes in magnetic properties of the CFAS film are correlated to structural ...

11

An electron energy loss spectroscopy and electron diffraction study of the Pmnb polymorph of Li2MnSiO4

An electron energy loss spectroscopy and electron diffraction study of the Pmnb polymorph of Li2MnSiO4

... The electron energy loss spectroscopy (EELS) spectra of lithium-transition metal compounds can be used to determine the valence state of the transition metal cations in the ...transmission ...

25

Simulation of electron energy loss spectra of nanomaterials with linear scaling density functional theory

Simulation of electron energy loss spectra of nanomaterials with linear scaling density functional theory

... This work was performed using the Darwin Supercomputer of the University of Cambridge High Performance Computing Service (www.hpc.cam.ac.uk/), provided by Dell Inc. using Strategic Research Infrastructure Funding from ...

12

Electron irradiation of nuclear graphite studied by transmission electron microscopy and electron energy loss spectroscopy

Electron irradiation of nuclear graphite studied by transmission electron microscopy and electron energy loss spectroscopy

... an electron flux of approximately ...EELS energy resolution of ...and energy loss spectra were captured using a Gatan Imaging Filter (GIF) 200 with a 1 megapixel slow scan CCD ...array. ...

25

Enhanced relativistic-electron-beam energy loss in warm dense aluminum

Enhanced relativistic-electron-beam energy loss in warm dense aluminum

... Our data and simula- tions unravel the role of resistive losses in REB transport, linked to the target resistivity, both the initial difference due to shock-induced heating yielding higher e-e collision frequency, ...

6

Optical properties of Ti, Zr, and Hf from 0 15 to 30 eV

Optical properties of Ti, Zr, and Hf from 0 15 to 30 eV

... The data were Kramers-Kronig analyzed to determine the dielectric ...higher energy could be related to transitions involving highlying bands and the core ...The electron-energy-loss ...

10

Anisotropic Approach for Simulating Electron Transport in Layered Materials: Computational and Experimental Study of Highly Oriented Pyrolitic Graphite

Anisotropic Approach for Simulating Electron Transport in Layered Materials: Computational and Experimental Study of Highly Oriented Pyrolitic Graphite

... input data of the energy-dependent dielectric function, of REEL and SE spectra of graphite, taking into ac- count features related to the anisotropic structure of the target ...the electron transport ...

22

Effect of annealing on the structure and magnetic properties of Co2FeAl0.5Si0.5 thin films on Ge(111)

Effect of annealing on the structure and magnetic properties of Co2FeAl0.5Si0.5 thin films on Ge(111)

... transmission electron microscopy (STEM) and electron energy loss spectroscopy (EELS) measurements reveal that the changes in magnetic properties of the CFAS film are correlated to structural ...

10

Electron spectroscopy of selected atmospheric molecules and hydrocarbons

Electron spectroscopy of selected atmospheric molecules and hydrocarbons

... high energy inelastic scattering, ionisation processes and ...theoretical data available for most diatomics and polyatomics due, in part, to problems evolving from the multi-centred and non-spherical nature ...

231

Question: Do all electrons in the same level have the same energy?

Question: Do all electrons in the same level have the same energy?

... each electron but you can make reasonable estimates based on the first ionization energy for lithium and the PES for ...the data for lithium from Shell Activity to help make your ...

15

High-Resolution Metallography of a Coarse Microstructure: Graphite Formation in the Solid-State in Steel

High-Resolution Metallography of a Coarse Microstructure: Graphite Formation in the Solid-State in Steel

... core loss region of the C K-edge (arising from ionisation of carbon 1s electrons to unoccupied p electron states above the Fermi level) from the crystalline and corresponding amorphous regions of two ...

19

Visualization of Electrochemical Reactions in All Solid State Li Ion Batteries by Spatially Resolved Electron Energy Loss Spectroscopy and Electron Holography

Visualization of Electrochemical Reactions in All Solid State Li Ion Batteries by Spatially Resolved Electron Energy Loss Spectroscopy and Electron Holography

... with electron diffraction and ex situ SR-TEM-EELS were supported by the RISING project of the New Energy and Industrial Technology Development Organization (NEDO) in ...

8

Scaling laws for positron production in laser-electron-beam collisions

Scaling laws for positron production in laser-electron-beam collisions

... GeV electron beams and laser pulses with intensity in the high 1 × 10 21 W cm − 2 is approximately 30 fs, which is close to the characteristic duration of current high-intensity ...characteristic energy of ...

12

Multistage coupling of laser-wakefield accelerators with curved plasma channels

Multistage coupling of laser-wakefield accelerators with curved plasma channels

... laser energy depletion for high-energy applications such as TeV-level electron-positron ...controlling electron beam focus- ing with plasma ...the electron beam and the laser pulse into ...

6

CH27

CH27

... transferred energy and momentum to them. Compton thought that these photon- electron collisions were similar to the elastic collisions experienced by billiard balls, as shown in Figure ...the energy ...

24

Effects of Homogeneous Low Energy Electron Beam Irradiation (HLEBI) on Water Absorption and Hydrolysis Suppression of High Strength Polycarbonate

Effects of Homogeneous Low Energy Electron Beam Irradiation (HLEBI) on Water Absorption and Hydrolysis Suppression of High Strength Polycarbonate

... Figure 9 shows FT-IR signals of PC before and after HLEBI (a) and its difference (b). HLEBI reduces the height of most peaks and then suppresses the light transmission of PC. When the remarkable negative difference of ...

6

Show all 10000 documents...