• No results found

load current

The Saw Gin Stand with Adjustable Movement of the Roll Box

The Saw Gin Stand with Adjustable Movement of the Roll Box

... gin’s load current sen- sor gives a signal to the frequency inverter 7 which regulates the speed of the motor 6 rotating the feed rollers 1, thereby changing the feed rate of the seed cotton into the roll ...

9

An Artificial Neural Network Based Power Converter for the Control of Positive and Negative Sequence Currents in Unbalance Ac Source

An Artificial Neural Network Based Power Converter for the Control of Positive and Negative Sequence Currents in Unbalance Ac Source

... p.u. load current in the faulty phase which is much larger than the currents in other two normal phases—this large current may cause overloading of the system and result in ...

13

Development of a Robust Constant Current Source For a Current Source Inverter S.Pradeepa 1, K.Uma Rao2 , Ravishankar Deekshit 3

Development of a Robust Constant Current Source For a Current Source Inverter S.Pradeepa 1, K.Uma Rao2 , Ravishankar Deekshit 3

... DC current source, has been assumed as ...the load current and load voltage waveforms are shown in ...output current remains depends on the magnitude of the input DC ...

7

MULTI CROSS PROTOCOL WITH HYBRID TOPOGRAPHY CONTROL FOR MANETS

MULTI CROSS PROTOCOL WITH HYBRID TOPOGRAPHY CONTROL FOR MANETS

... variable load condition. THDs were shown for source current and load current showing how effective the UPQC works for improving power ...

10

Power Quality Improvement of Distribution System using HCC Based FACTS Controller

Power Quality Improvement of Distribution System using HCC Based FACTS Controller

... a current wave such that it compensate by cancelling out the nonlinear current waveform generated by load ...the load nonlinearities. Fig. 2 shows the different waveforms i.e. the load ...

9

Enhancing Electric Power quality improvement solar sources by using UPQC

Enhancing Electric Power quality improvement solar sources by using UPQC

... for current and voltage in two-bus/two-feeder ...the load, voltage against disturbance and sag/swell in the system for protecting the sensitive critical loads and nonlinear sensitive ...

8

IMPROVED PERFORMANCE OF SPLIT CAPACITOR BASED DSTATCOM  FOR SHUNT APPLICATION

IMPROVED PERFORMANCE OF SPLIT CAPACITOR BASED DSTATCOM FOR SHUNT APPLICATION

... reference current and injected currents for only few portion of cycle fails to track phase ‘ a ’ and ‘ b ...’ current tracks exactly as shown in ...the current having zero sequence ...source ...

11

USING OF ANFIS AND FIS METHODS TO IMPROVE THE UPQC PERFORMANCE

USING OF ANFIS AND FIS METHODS TO IMPROVE THE UPQC PERFORMANCE

... and current flickering due to arc in arc furnaces, sag and swell due to the switching (on and off) of the loads ...the load current waveform and voltage ...

13

Harmonics Analysis Of A SPV Based Stand-Alone And Grid Connected Multilevel Inverter With Improved Power Quality At Different Load

Harmonics Analysis Of A SPV Based Stand-Alone And Grid Connected Multilevel Inverter With Improved Power Quality At Different Load

... nonlinear load connected at PCC, the variation of THD in PCC voltage, inverter output voltage, load voltage, load current and grid current and also the power send to the load as ...

9

SURVEILLANCE ENERGY METER

SURVEILLANCE ENERGY METER

... The current transformer in this project used as a sensing element and a transistor BC-547 as a control ...circuit. Current transformer is use to sense the load current and transistor is used ...

5

Multi-port Current Source Inverter for Smart Microgrid Applications: A Cyber Physical Paradigm

Multi-port Current Source Inverter for Smart Microgrid Applications: A Cyber Physical Paradigm

... and current, (b) EV mode output voltage and load current, (c) DV mode output voltage and load current, (d) EV mode output voltage and load current with step change, (e) EV ...

16

Matrix converter open circuit fault behavior analysis and diagnosis with a model predictive control strategy

Matrix converter open circuit fault behavior analysis and diagnosis with a model predictive control strategy

... capacitor current measurement is proposed. An additional current sensor is used in this method and the fault detection process is slowed down by the integration of the clamp circuit ...output current ...

10

GeneticAlgorithm based Analysis of Six phase Self excited Induction Generators for Wind Energy Conversion

GeneticAlgorithm based Analysis of Six phase Self excited Induction Generators for Wind Energy Conversion

... on load voltage and frequency is shown in ...no load to full ...stator current and load current with output power and it is observed that the stator current is within its rated ...

8

The effect of DC current on power transformers

The effect of DC current on power transformers

... magnetizing current and flux is a non-linear ...magnetizing current when a single phase transformer is exposed to biased load current operating ...flux-magnetising current relationship ...

149

ANALYSIS AND SIMULATION OF A CASCADED SHUNT ACTIVE POWER FILTER FOR ELECTRIC POWER SYSTEM

ANALYSIS AND SIMULATION OF A CASCADED SHUNT ACTIVE POWER FILTER FOR ELECTRIC POWER SYSTEM

... the load response, a feed forward path of the load current is ...and load conditions are ...7.2-kVA load power is built and tested in the ...

11

Download
			
			
				Download PDF

Download Download PDF

... the load current conduction modes in the one phase two-pulse PWM AC/DC ...various load current conduction modes are identified by the signs of the instantaneous load current ...

11

Performance evaluation of shunt active power 
		filters for different control strategies

Performance evaluation of shunt active power filters for different control strategies

... and load current sensors, replacement of SSTPI with FSTPI reduces the cost of the inverter, switching losses, and complexity of the control algorithm in practical ...the load side distortions are ...

7

Design and simulation of cascaded seven level inverter based on statcom

Design and simulation of cascaded seven level inverter based on statcom

... In conclusion, among the nature multilevel inverter topologies, the cascaded multilevel inverter is the most promising alternative for the STATCOM application and it requires the least number of switches as compared to ...

7

Download
			
			
				Download PDF

Download Download PDF

... of load performance was ...power, load voltage and load current increases with increase in load power factors while the phase voltage, phase current, capacitor current and ...

7

Volume 2, Issue 7, July 2013 Page 243

Volume 2, Issue 7, July 2013 Page 243

... We have to connect the load by priority means that we connect high priority front (like ballroom, study room, kitchen ..) and the second line connecting low priority compared with the first (as the balcony of the ...

6

Show all 10000 documents...