• No results found

Steady state error

Control System Design For Temperature Alert System

Control System Design For Temperature Alert System

... 5.6.1 Transfer Function of the System (Car Engine Block) 92 5.6.2 Block Diagram of the System (Car Engine Block) 93 5.6.3 Controller of the System (Car Engine Block) 93 5.6.4 Steady-state Error of ...

24

Comparison between Genetic Algorithm and Simulated Annealing Technique of Lag-Lead Compensator

Comparison between Genetic Algorithm and Simulated Annealing Technique of Lag-Lead Compensator

... A simple layout procedure of a lead-lag controller to satisfy or nearly meet the planning specification via genetic algorithmic program has been proffered in this research paper. A main aspect of our way is to ...

11

Review On Adaptive Blind Channel Estimation Using LMS Based Techniques In OFDM Systems

Review On Adaptive Blind Channel Estimation Using LMS Based Techniques In OFDM Systems

... and steady state ...and steady state error, while a constant scalar step size is utilized in NLMS algorithm that effectively avoids the fast ...deliver steady state MSE ...

5

A variable-parameter normalized mixed-norm (VPNMN) adaptive algorithm

A variable-parameter normalized mixed-norm (VPNMN) adaptive algorithm

... Since both the least mean-square (LMS) and least mean-fourth (LMF) algorithms suffer individually from the problem of eigenvalue spread, so will the mixed-norm LMS-LMF algorithm. Therefore, to overcome this problem for ...

13

System identification and control of a 
		hydraulic actuator

System identification and control of a hydraulic actuator

... zero steady state error, ...0.21% steady state error, ...0.1% steady state error, an undershoot of ...

5

A NEW ADAPTIVE BEAMFORMING ALGORITHM FOR SMART ANTENNA

A NEW ADAPTIVE BEAMFORMING ALGORITHM FOR SMART ANTENNA

... A novel method for improving the convergence rate, as well as reducing the steady state error of a conventional NLMS algorithm, is proposed in this paper. The convergence speed of the proposed ...

6

Design of PWM-Based Sliding-Mode Control of Boost Converter with Improved Performance

Design of PWM-Based Sliding-Mode Control of Boost Converter with Improved Performance

... Following are the areas of future study which can be considered for further research work.The proposed control method is applied on dc-dc boost converter. It can be applied to many other converter topologies. The non ...

8

1.
													Stability analysis of golden-section adaptive controllers for switched reluctance motor characteristic model

1. Stability analysis of golden-section adaptive controllers for switched reluctance motor characteristic model

... Proportional-Integral (PI) controllers are widely used in Switched reluctance motor drive for accurate speed control and better speed holding capacity. The combination of proportional and integral increases the speed of ...

9

STUDY OF APPLICATION OF FUZZY-PID DRUM LEVEL CONTROL FOR BOILER

STUDY OF APPLICATION OF FUZZY-PID DRUM LEVEL CONTROL FOR BOILER

... Boiler unit plays essential role in power plant and controlling the boiler drum level is one of the important operations. Nowadays, conventional Proportional plus Derivative plus Integral (P+I+D) control is being used ...

13

Reliable Robust Sampled-Data H∞ Output Tracking Control with Application to Flight Control

Reliable Robust Sampled-Data H∞ Output Tracking Control with Application to Flight Control

... 1) This is the first paper that a controller is designed to make the output of uncertain sampled-data system to track the reference signal without steady- state error, and the results can be applied ...

8

ECE-320 : Linear Control Systems

ECE-320 : Linear Control Systems

... use state variable feedback of the form u t ( ) = G r t pf ( ) − kq t ( ) , where is the new input to the system, is a prefilter (for controlling steady state error), and is the state ...

8

Lab 4: Root Locus For Controller Design

Lab 4: Root Locus For Controller Design

... This is second order system with two real poles, located at -5 and -6. Our general goal will be to speed up the response of the system and produce a system with a steady state error for a unit step ...

9

Step 1: Set up the 1 dof system exactly the way it was when you determined its model parameters. Step 2: Modify closedloop_driver.m to read in the correct model file. You may have to copy this

Step 1: Set up the 1 dof system exactly the way it was when you determined its model parameters. Step 2: Modify closedloop_driver.m to read in the correct model file. You may have to copy this

... • Change the prefilter in closedloop.mdl to cancel the zeros of the closed loop system and still have a steady state error of zero. Since the PID controller makes the system a type 1 system, we don't ...

7

1) For the following problem, assume we are using the following control system

1) For the following problem, assume we are using the following control system

... the steady state error for a unit ramp is We will be varying the locations of the pole and zero of the lag compensator to accomplish this, and will look at the effects of these changes on both the ...

6

Utilization of Bacterial Foraging Algorithm for Optimization of Boost Inverter Parameters

Utilization of Bacterial Foraging Algorithm for Optimization of Boost Inverter Parameters

... This paper proposes a boost inverter model capable of coping with changes in load as well as line parameters. In order to achieve an output AC voltage higher than the input DC voltage, we can use this model consisting of ...

11

Design, Analysis, And Computational Methods For Engineering Synthetic Biological Networks

Design, Analysis, And Computational Methods For Engineering Synthetic Biological Networks

... (zero steady state error if the closed loop system is stable) and a flexible implementation of the process ...zero steady state error (if the closed loop system is stable) in ...

134

DEVELOPMENT OF PID LIKE FLC ALGORITHM FOR INDUSTRIAL APPLICATIONS

DEVELOPMENT OF PID LIKE FLC ALGORITHM FOR INDUSTRIAL APPLICATIONS

... and steady state error is produced, generating the gain of the proportional term increases the speed of the system response and reduces the steady state ...The steady ...

12

A Sensorless Current Controlled DC-DC Converter with Intelligent Control Technique

A Sensorless Current Controlled DC-DC Converter with Intelligent Control Technique

... voltage steady-state error and achieve high-accuracy current estimation without using current ...voltage steady-state error and achieve high-accuracy current estimation purpose ...

8

Lecture12-SteadyStateError

Lecture12-SteadyStateError

... Page : 1 EE406 Control Systems Lecture 12 : Steady State Error.. UCSI University Faculty of Engineering.[r] ...

19

Observation of System Performance for Lag Compensation from Universal Design Method

Observation of System Performance for Lag Compensation from Universal Design Method

... ABSTRACT: Compensators are corrective sub systems to force the chosen plant to meet the given specifications. Their purpose is to compensate for the deficiency in the performance of the plant. The Universal chart ...

7

Show all 10000 documents...

Related subjects