• No results found

voltage controlled current shunt

SIMULATION AND FUZZY LOGIC CONTROL OF SHUNT HYBRID POWER FILTER AND THYRISTOR-CONTROLLED REACTOR FOR POWER QUALITY

SIMULATION AND FUZZY LOGIC CONTROL OF SHUNT HYBRID POWER FILTER AND THYRISTOR-CONTROLLED REACTOR FOR POWER QUALITY

... suppress current harmonics and compensate the reactive power generated from the ...The shunt APF when used alone suffers from the high kilo volt ampere rating of the inverter, which requires a lot of energy ...

11

Three phase Shunt Active power filter for harmonic reduction in non linear loads

Three phase Shunt Active power filter for harmonic reduction in non linear loads

... A shunt active power filter that achieves low current total harmonic distortion, reactive power compensation, is ...IGBT's voltage inverter, intended to damp harmonics produced by a diode ...The ...

6

FUZZY BASED SHUNT ACTIVE POWER FILTER FOR POWER QUALITY ENRICHMENT

FUZZY BASED SHUNT ACTIVE POWER FILTER FOR POWER QUALITY ENRICHMENT

... the voltage and current harmonics present in the nonlinear ...logic controlled Shunt Active Power Filter (SAPF) and conventional (PI) controlled shunt active power filter on ...

11

Performance assessment of direct and indirect current control strategies 
		for shunt active power filter

Performance assessment of direct and indirect current control strategies for shunt active power filter

... Direct Current Control Technique (DCCT) and Indirect Current Control Technique (ICCT) for the control of Shunt Active Power Filter ...A current controlled voltage source inverter ...

8

Performance Analysis of Fuzzy Logic Based PI Controller

Performance Analysis of Fuzzy Logic Based PI Controller

... link voltage at desired level and error obtained by fuzzy logic based PI controller is used for reference current ...hysteresis current control has one of the highest rates of quick current ...

10

Fuzzy Logic Controller Implementation of Power Quality Improvement Using UPQC

Fuzzy Logic Controller Implementation of Power Quality Improvement Using UPQC

... the shunt inverter to the system. It also helps in smoothing the current wave ...bus voltage across ...the current or vol- tage rating of the series ...of shunt and series APFs with a ...

25

Analyse the Limit Fault Currents and Pre Fault Bus Voltage by Using TCPST

Analyse the Limit Fault Currents and Pre Fault Bus Voltage by Using TCPST

... and shunt synchronous voltage source equivalent; (c) a series injected voltage source and a shunt injected current source The TCPST consists of two transformers; a shunt ...

10

THD reduction using Shunt Active Filter

THD reduction using Shunt Active Filter

... A shunt active filter connected to a simple power system is shown in ...phase voltage source (Va, Vb , Vc) feeding a three phase diode bridge rectifier with resistive ...a current controlled ...

7

Simulation Study for Reactive Power Compensation Using STATCOM

Simulation Study for Reactive Power Compensation Using STATCOM

... the voltage in series with the transmission line with any phase angle according to driving voltage to control the line ...The shunt controller draws or injects the current into the power ...of ...

7

Vol 3, No 1 (2015)

Vol 3, No 1 (2015)

... of Shunt and Series VSC which are controlled ...the shunt VSC are selected to be sinusoidal pulse width modulation (PWM) voltage control and hysteresis current control, ...

9

Unit Vector Theory based Unified Power Quality Conditioner for Power Quality Improvement

Unit Vector Theory based Unified Power Quality Conditioner for Power Quality Improvement

... series controlled UPQC. It is the dual of the shunt APF, and is able to compensate for distortion in the power line voltages, making the voltages applied to the load sinusoidal (compensating for ...

11

Power Quality Improvement by Using Shunt Hybrid Power Filter and Thyristor Controlled Reactor with Fuzzy Logic Controller

Power Quality Improvement by Using Shunt Hybrid Power Filter and Thyristor Controlled Reactor with Fuzzy Logic Controller

... block current harmonics. Shunt filters still dominate the harmonic compensation at medium/high voltage level, whereas active filters have been proclaimed for low/medium voltage ...

11

Contribution of the UPFC in Improving the Quality of Electrical Power

Contribution of the UPFC in Improving the Quality of Electrical Power

... the shunt converter should be equal to the active power generated by the series ...the shunt or series converter can be chosen independently, giving greater flexibility to the power flow ...

8

A Novel Scheme of Harmonics Mitigation by Using Single Tuned and Double Tuned Passive Harmonics Filters

A Novel Scheme of Harmonics Mitigation by Using Single Tuned and Double Tuned Passive Harmonics Filters

... The Maximum frequency harmonics may also causes interference to nearby which telecommunication system. In electrical power system harmonics is a seen for long time but major of problems related to harmonics are come in ...

9

Reduction of Harmonics by Using Active and Passive Harmonics Filters

Reduction of Harmonics by Using Active and Passive Harmonics Filters

... the current harmonics, the passive filters also provide reactive power compensation, thereby, further improving the system ...performance. Voltage and current source type of harmonic producing loads, ...

9

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

... DC-link voltage ( ) has since it has only two legs compared to the six-switch APF as shown in ...DC-Link voltage that helps in smoothing the reference current ...DC-link voltage in the VPI ...

7

APPLICATION OF BOOST INVERTER FOR GRID CONNECTED FUEL CELL BASED POWER GENERATION

APPLICATION OF BOOST INVERTER FOR GRID CONNECTED FUEL CELL BASED POWER GENERATION

... these drawbacks, a topology that is suitable for ac loads and is energized from dc sources able to boost and invert the voltage at the same time has been recommended. The double loop control strategy of this ...

6

Bandwidth Extension of BJT Amplifier using a Novel Cascade Topology

Bandwidth Extension of BJT Amplifier using a Novel Cascade Topology

... Conventional BJTs have limited frequency response range. In any amplifier design, it is always necessary to give utmost attention to its frequency response analysis. While applying frequency response for some application ...

5

Hysteresis Current Controlled High Power Factor Three Phase PWM Converter

Hysteresis Current Controlled High Power Factor Three Phase PWM Converter

... Hysteresis current control technique in three phases PWM ...in current which affect the ...more current than a load with high power factor for the same amount of useful power transferred to eliminate ...

9

Temperature Effects on the Electrical Performance of Large Area Multicrystalline Silicon Solar Cells Using the Current Shunt Measuring Technique

Temperature Effects on the Electrical Performance of Large Area Multicrystalline Silicon Solar Cells Using the Current Shunt Measuring Technique

... It is concluded that, using the 20 Ampere (Holt HCS-1) current shunt measuring technique prove to be very sat- isfactory. It is not only very stable under a wide range of ambient temperatures from 5ºC up to ...

7

Show all 10000 documents...

Related subjects