[PDF] Top 20 High resolution whole brain diffusion imaging at 7 T for the Human Connectome Project
Has 10000 "High resolution whole brain diffusion imaging at 7 T for the Human Connectome Project" found on our website. Below are the top 20 most common "High resolution whole brain diffusion imaging at 7 T for the Human Connectome Project".
High resolution whole brain diffusion imaging at 7 T for the Human Connectome Project
... vs. 7 s) of the 7 T data (Ugurbil et ...3 T data, the 7 T data exhibits a number of interesting features in fractional anisotropy (FA) and DTI principal direction of ... See full document
36
Development of High Angular Resolution Diffusion Imaging Analysis Paradigms for the Investigation of Neuropathology
... altered brain growth trajectories [43] in subjects di- agnosed with ...A high b-value (3000 s/ mm 2 ) DW-MRI acquisition was used to provide optimal data for the FOD ... See full document
141
Diffusion tensor echo planar imaging with high spatial resolution and its applications
... the brain is the centre of ...of human brain is quite ...the human brain, cognitive function does not occur as a single ...the brain occurs in anatomically distinct regions, ... See full document
166
The intrinsic geometry of the human brain connectome
... acquired brain MRI data on a Philips ...coil. High-resolution three-dimensional (3D) T1-weighted images were acquired with a MPRAGE (magnetization prepared rapid acquisition gradient echo) sequence ... See full document
14
Q&A: Why use synchrotron x-ray tomography for multi-scale connectome mapping?
... X-ray imaging satisfies all of the above requirements [3– ...the whole brains of animals used as model or- ...a high resolution optical microscope, AXON microtomogra- phy (micro-AXON) allows ... See full document
9
Toward Precision and Reproducibility of Diffusion Tensor Imaging: A Multicenter Diffusion Phantom and Traveling Volunteer Study
... a human volunteer, the 3T high-angular- resolution diffusion imaging protocol yielded CoVs below 5% for FA, MD, AD, and RD, averaged over the white matter skeleton of the whole ... See full document
9
The minimal preprocessing pipelines for the Human Connectome Project
... and diffusion, together into a cohesive framework to enable cross-subject comparisons and multi-modal analysis of brain architecture, connectivity, and ...the imaging modalities include T1- weighted ... See full document
50
Acute Effects of Alcohol on the Human Brain: Diffusion Tensor Imaging Study
... Significant differences were observed for ADC values in the frontal lobe and middle cerebellar peduncle between the pre- alcohol state and 1 and 2 hours (P ⬍ .01) after acute alcohol administration in both the ... See full document
7
The role of dual spin echo in increasing resolution in diffusion weighted imaging of brain
... MR imaging was performed using a ...using high division neuron vascular (HDNV) array 8 channel coil, firstly routine study was done, T2-FSE (TR/TE,4160/103 ms), the T1- memp/75 (TR/TE,480/12 ms) ,T2 FLAIR ... See full document
6
Functional Imaging Connectome of the Human Brain and its Associations with Biological and Behavioral Characteristics
... 738, number of training subjects and 𝑛𝑡𝑠(= 82, number of testing subjects).................................... 68 Figure 4. 3 Effect of number of components in PLS regression on gender predictions performance (AUC), ... See full document
168
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
... particular, diffusion MRI (dMRI) and tractography algorithms (see (Behrens and Jbabdi, 2009) for a review) have allowed novel explorations of inter-regional pathways in the living ...for whole-brain ... See full document
38
Automated processing pipeline for neonatal diffusion MRI in the developing Human Connectome Project
... developing Human Connectome Project is set to create and make available to the scientific community a 4- dimensional map of functional and structural cerebral connectivity from 20 to 44 weeks ... See full document
14
High Resolution Diffusion Tensor Imaging of the Brain Stem at 3 T
... 3-T high-spatial-resolution brain stem imaging with SENSE ...isotropic resolution, ...the brain stem region. The imaging matrix was 112 ⫻ 109, which was zero-filled ... See full document
6
Forensic Application of Postmortem Diffusion Weighted and Diffusion Tensor MR Imaging of the Human Brain in Situ
... of brain injury (ie, mechanical brain trauma and hypoxic injury due to ...with brain injury with those having died from cardiac failure (Fig ... See full document
7
High Angular Resolution Diffusion Imaging Probabilistic Tractography of the Auditory Radiation
... nique is a method to determine the probability distribution of fiber orientations from 1 diffusion MR acquisition. It is necessary to launch a large number of trajectories from the starting region to probe the ... See full document
6
Brain connectomic associations with traditional Chinese medicine diagnostic classification of major depressive disorder: a diffusion tensor imaging study
... of Diffusion Toolbox of Functional MRI of the Brain (FMRIB) software ...A diffusion tensor model was then generated for each voxel to obtain three eigenvec- tors and three ...eigenvalues. ... See full document
10
Diffusion imaging of the human brain: a new pulse sequence application for a 1 5 T standard MR system
... The following regions reveal faster diffusion brighter on the image than the contralateral correspondents: the right posterior limb of the internal capsule large arrows, the left anterio[r] ... See full document
6
Two-dimensional enrichment analysis for mining high-level imaging genetic associations
... Preprocessed [18F]Florbetapir PET scans (i.e., amyloid imaging data) were downloaded from adni.loni.usc.edu, then aligned to the corresponding MRI scans and normal- ized to the Montreal Neurological Institute ... See full document
11
High Resolution Ultrasound in Research of Mouse Orthotopic Glioma and Ultrasound Guided Cell Implant
... Normal brain, of 6 pups (5 to 10 days old) and 10 adult (more than 4 weeks old) mice, was studied by HiRes US (Vevo 2100 system; VisualSonics, Toronto, Canada) equipped with broadband (18 MHz - 38 MHz) mechani- ... See full document
9
High b Value Diffusion Tensor Imaging of the Neonatal Brain at 3T
... Conventional Imaging. Infant 1 (gestational age 41 weeks, female, scan day 7) had perinatal ...Infant 7 (42 weeks, female, scan day 9) had hypotonia, hip contractures, and poor ...asphyxia. ... See full document
7
Related subjects