• No results found

[PDF] Top 20 Seismic Proving Test of Eroded Piping (K308)

Has 10000 "Seismic Proving Test of Eroded Piping (K308)" found on our website. Below are the top 20 most common "Seismic Proving Test of Eroded Piping (K308)".

Seismic Proving Test of   Eroded Piping (K308)

Seismic Proving Test of Eroded Piping (K308)

... the piping system test was conducted by using the material property that could evaluate the strain range ...the piping model as the forced deflection and comparing the calculated and observed strain ... See full document

8

On categorization of seismic load as primary or secondary in piping systems

On categorization of seismic load as primary or secondary in piping systems

... pressurized piping configurations tested on shaking ...the test designers decided to focus on investigating this failure mode instead of trying to identify the available seismic margin for a single ... See full document

10

Experimental   Study on Fracture Behavior of Piping Support under Seismic Loading (Verification   Test using Shaking Table) (K110)

Experimental Study on Fracture Behavior of Piping Support under Seismic Loading (Verification Test using Shaking Table) (K110)

... measured seismic wave at Kobe Ocean Meteorological Observatory in 1995 (This is indicated as “Kobe earthquake” in this report) and an artificial earthquake wave S2 for evaluation of a practical nuclear power plant ... See full document

7

Test and Analysis Research on Seismic Structural Integrity of Nuclear Power Pipeing

Test and Analysis Research on Seismic Structural Integrity of Nuclear Power Pipeing

... on test and calculation results as well as relevant code items in RCC-M ,ASME and Chinese seismic design codes, it is suggested that damping ratio shall have a value of 5% for piping structure which ... See full document

7

Using Component Test Data to Assist in Establishing Code Criteria to Achieve the Desired Seismic Capacity Margin for Piping

Using Component Test Data to Assist in Establishing Code Criteria to Achieve the Desired Seismic Capacity Margin for Piping

... The nonlinear factor FNL is highly sensitive to both the ratio Rw of the central frequency of the input motion to the component natural frequency, and the breadth of the frequency [r] ... See full document

25

Seismic   Proving Test of a Reinforced Concrete Containment Vessel (RCCV) Part 4.   Results of Shaking Table Tests up to the Ultimate Strength

Seismic Proving Test of a Reinforced Concrete Containment Vessel (RCCV) Part 4. Results of Shaking Table Tests up to the Ultimate Strength

... The following are the major results. 1) In the tests from 2S2(H) to 5S2(H), no structural collapse occurred and no failure in the leak-tight function of the liner system was o[r] ... See full document

8

Seismic safety evaluation of industrial piping systems and components under serviceability and ultimate limit state conditions.

Seismic safety evaluation of industrial piping systems and components under serviceability and ultimate limit state conditions.

... the test is conducted in real time, the dynamics of the testing system and specimen become ...the test specimen, a time lag exists between when the displacement is commanded and when the actu- ator actually ... See full document

261

Realistic Seismic Evaluation of Non-Qualified Piping with Threaded Fittings

Realistic Seismic Evaluation of Non-Qualified Piping with Threaded Fittings

... verify seismic capability utilizes realistic seismic demand and realistic capacity ...table test data demonstrates that the realistic analysis criteria, while not necessarily as conservative as the ... See full document

7

DEVELOPMENT OF EVALUATION METHOD FOR SEISMIC ISOLATION SYSTEMS OF NUCLEAR POWER FACILITIES - SEISMIC DESIGN AND ANALYSIS FOR CROSSOVER PIPING -

DEVELOPMENT OF EVALUATION METHOD FOR SEISMIC ISOLATION SYSTEMS OF NUCLEAR POWER FACILITIES - SEISMIC DESIGN AND ANALYSIS FOR CROSSOVER PIPING -

... scaled piping model and the FEM analyses have been performed to investigate the seismic response and failure behaviour of crossover ...crossover piping model was excited and deformed by the two ... See full document

10

Fatigue-Ratcheting Study of Pressurized Piping System under Seismic Load

Fatigue-Ratcheting Study of Pressurized Piping System under Seismic Load

... plant piping systems may be loaded into the plastic range due to large amplitude reversible cyclic loading like seismic ...pressurized piping system. The piping system is pressurized with ... See full document

7

Examples of categorization of seismic load for civil engineering and mechanical engineering

Examples of categorization of seismic load for civil engineering and mechanical engineering

... scale piping system under consideration consisted of a 200 mm (8 inch) nominal diameter schedule 40 carbon steel ...The piping system included straight pipe, nine elbows, a tee, and a 1000 kg added mass ... See full document

9

An Experimental Investigation on Failure Modes of Piping Components under Excessive Seismic Load

An Experimental Investigation on Failure Modes of Piping Components under Excessive Seismic Load

... excessive seismic loads are mainly thought to be 1) fatigue failure, 2) ratchet-collapse, and 3) ductile fracture in the case of low ductile ...plate-type test pieces and the pipe elbow ...the test ... See full document

8

Equivalent linearization using transfer function applied to piping systems in seismic engineering

Equivalent linearization using transfer function applied to piping systems in seismic engineering

... design seismic hazard has become a prior concern that has increased the need of evaluations of NNP’s structures or their components within a higher level of seismic load by taking into account nonlinear ... See full document

10

Seismic Fragility Estimates of Piping System of Base-isolated Nuclear Power Plant

Seismic Fragility Estimates of Piping System of Base-isolated Nuclear Power Plant

... in piping system was defined as a weakness element and numerical model was updated by component ...of piping component under seismic load was defined in conservative terms as cases in which ... See full document

10

Seismic Fragility of Piping Systems: Consideration of Cyclic Behavior and Closed-Form Relationship.

Seismic Fragility of Piping Systems: Consideration of Cyclic Behavior and Closed-Form Relationship.

... improved seismic fragilities. As per Gilmore & Jirsa (2005), a seismic analysis & design procedure which doesn’t take into account the cumulative plastic deformation demands under earthquake ground ... See full document

156

Inelastic Seismic Test of the Small Bore Piping and Support System

Inelastic Seismic Test of the Small Bore Piping and Support System

... element test as shown in Table 1 have been proceeding, selecting test parameters such as element type, pipe size, dimensions of support element, and anchor ...both test models of cantilever type ... See full document

7

BNL Nonlinear Pre-Test Seismic Analysis for the  NUPEC Ultimate Strength Piping Test Program (K255)

BNL Nonlinear Pre-Test Seismic Analysis for the NUPEC Ultimate Strength Piping Test Program (K255)

... plant piping systems under large seismic ...material, piping component and piping system ...on seismic issues, the US Nuclear Regulatory Commission (USNRC) and its contractor, the ... See full document

8

Seismic   Proving Test of Heavy Component with Energy Absorbing Supports

Seismic Proving Test of Heavy Component with Energy Absorbing Supports

... The Seismic Proving Test of Heavy Component with Energy Absorbing Supports has been conducted to prove the reliability of advanced seismic technology, supporting h[r] ... See full document

8

Seismic Proving Test of   Ultimate Piping Strength (Status of Design Method Confirmation Test)   (K368)

Seismic Proving Test of Ultimate Piping Strength (Status of Design Method Confirmation Test) (K368)

... target test conditions that are equivalent to the pre-test analysis conditions shown in Table ...input seismic wave spectrum on the table differed from the target spectrum and the maximum ... See full document

8

Seismic Fragility of Piping System.

Seismic Fragility of Piping System.

... actual test set-up for determining the force-displacement and moment-rotation relationships of the threaded Tee-joint connection under monotonic and cyclic loading ...The test-setup was erected in such a ... See full document

192

Show all 10000 documents...