• No results found

critical fault-clearing time

Transient stability assessment for single-machine power systems using neural networks

Transient stability assessment for single-machine power systems using neural networks

... The part of work on the estimation of critical fault clearing time indicates that neural networks can be used to restrict the range of critical fault clearing times f[r] ...

6

Protection Scheme Based on Analysis of Critical Clearing Time of System

Protection Scheme Based on Analysis of Critical Clearing Time of System

... a fault is implanted in bus number 5 and an appropriatefault clearing time is set for which stability of the system is analysed by eigenvalue analysis and through the stability indices for limit ...

10

Analytical approximations of critical clearing time for parametric analysis of power system transient stability

Analytical approximations of critical clearing time for parametric analysis of power system transient stability

... In general, a power network’s topology changes from its original structure when a fault is cleared. This is generally due to some switching action that isolates the region of the network that suffers the ...

13

Transient Stability Assessment of Hybrid Distributed Generation and its Impact on Critical Clearing Time and Oscillation Duration Considering its Complementary Nature

Transient Stability Assessment of Hybrid Distributed Generation and its Impact on Critical Clearing Time and Oscillation Duration Considering its Complementary Nature

... the fault is cleared because the rotor side converter cannot provide the necessary reactive power to the generator for magnetization ...settling time. The settling time when HYBRID DFIG+SOLAR PV is ...

16

Transient Stability Analysis of a Two-Machine Power System under Different Fault Clearing Times

Transient Stability Analysis of a Two-Machine Power System under Different Fault Clearing Times

... and critical clearing times as compared to traditional energy functions, numerical energy functions and two time-scale energy functions ...system, fault type and location, and fault ...

6

A single machine equivalent approach for 
		the amelioration of critical clearing time limit

A single machine equivalent approach for the amelioration of critical clearing time limit

... the fault from a healthy system. Therefore from an inappropriate time for disconnecting the transmission line, it will cause a generator to experience the loss of synchronism which may instigate the ...

8

Design of Simulation forTransient Stability Analysisin Smart Grid by Using Critical Clearing Time Index

Design of Simulation forTransient Stability Analysisin Smart Grid by Using Critical Clearing Time Index

... computational time in real time ...computation time required through the simulation proposed in this ...discrete time equations describing the time evolution of all machines in the ...

5

EFFECT OF FAULT LOCATION AND LOAD INCREMENT ON TRANSIENT STABILITY OF POWER SYSTEM

EFFECT OF FAULT LOCATION AND LOAD INCREMENT ON TRANSIENT STABILITY OF POWER SYSTEM

... the Critical Clearing Time ...three-phase fault was simulated at bus 1 with the opening of line 1–4 to clear the ...the Critical Clearing ...the Critical Clearing ...

9

Critical Clearing Time prediction within various loads for transient stability assessment by means of the Extreme Learning Machine method

Critical Clearing Time prediction within various loads for transient stability assessment by means of the Extreme Learning Machine method

... The Critical Clearing Time (CCT) is a key issue for Transient Stability Assessment (TSA) in electrical power system operation, security, and ...the critical trajectory method based on ...

8

A Practical Method for Power Systems Transient Stability and Security

A Practical Method for Power Systems Transient Stability and Security

... a fault occurs, the equilibrium is disturbed causing the synchronous machines to ...the fault-on period causing the system to move away from the ...After clearing the fault, the kinetic energy ...

112

 AN EFFICIENT INFORMATION RETRIEVAL SYSTEM USING QUERY EXPANSION AND 
DOCUMENT RANKING

 AN EFFICIENT INFORMATION RETRIEVAL SYSTEM USING QUERY EXPANSION AND DOCUMENT RANKING

... ground fault at various ...the critical clearing time using ETAP software. The fault clearing time is increased up to the critical clearing time to ...

7

TRANSIENT STABILITY ANALYSIS AND ENHANCEMENT OF IEEE- 9 BUS SYSTEM

TRANSIENT STABILITY ANALYSIS AND ENHANCEMENT OF IEEE- 9 BUS SYSTEM

... Transient stability analysis has been performed on ETAP software. The Critical Clearing time (CCT) i.e. the maximum allowable value of the clearing time for which the system remains to ...

11

Optimal Design of Earthmat for 110kV Substation using ETAP 12.6

Optimal Design of Earthmat for 110kV Substation using ETAP 12.6

... that fault currents dissipate mainly through the earthing electrode into the ground, whilethe values of electrical potentials between close points on the earth surface that can be connected by a person must be ...

6

A design for testability study on a high performance automatic gain control circuit

A design for testability study on a high performance automatic gain control circuit

... The AGC design does not provide a stand-by mode to reduce the power consumption, this is however not the case in the next generation designs. In figure 8, a section of the OP1 schematic is shown, including the most ...

10

500 kV Single Phase Reclosing Evaluation Using Simplified Arc Model

500 kV Single Phase Reclosing Evaluation Using Simplified Arc Model

... dead time setting and reclose both end breakers as quickly as possible after completely arc extinction for enhancing the operational availability of the ...

12

The Supervisory Framework Surrounding Nonbank Participation in the U.S. Retail Payments System: An Overview. Richard J. Sullivan*

The Supervisory Framework Surrounding Nonbank Participation in the U.S. Retail Payments System: An Overview. Richard J. Sullivan*

... over time, but it is uncertain whether the evolution of the supervisory process is sufficient to manage the risks that have accompanied the trend towards more nonbank companies providing electronic payment ...

61

Directional Comparison Blocking System Fundamentals

Directional Comparison Blocking System Fundamentals

... where fault resistance is not ...long time delay for a sensitive directional ground tripping element (67NF) is therefore often used when applied with a forward ground distance tripping element (21NF) in a ...

23

Test Plan for Real-Time Modeling & Simulation of Single Pole Switching Relays

Test Plan for Real-Time Modeling & Simulation of Single Pole Switching Relays

... The work done in this thesis is continuation of work published in [12] and [44]. [12] focused on evaluating performance of various digital line protection relays using a closed-loop real-time power system digital ...

122

Synthesizing Fault Tolerant Safety Critical Systems

Synthesizing Fault Tolerant Safety Critical Systems

... But, the proposed method of this paper included another novel point of view by keeping the earliest inconsistent transition in the program to continue the complete execution of a system. The program will transit from one ...

8

REDUCTION OF FAULT TIME IN SMART GRID SYSTEM USING FUZZY LOGIC CONTROLLER

REDUCTION OF FAULT TIME IN SMART GRID SYSTEM USING FUZZY LOGIC CONTROLLER

... of fault consists of three phase system which has toggle switch in each line at little distance and is used to arbitrarily create fault in each of the ...of fault as the four switches are placed in ...

9

Show all 10000 documents...

Related subjects