• No results found

electrical impedance tomography imaging system

Development of a high speed current injection and voltage measurement system for electrical impedance tomography based stretchable sensors

Development of a high speed current injection and voltage measurement system for electrical impedance tomography based stretchable sensors

... Abstract: Electrical impedance tomography (EIT) is an imaging method that can be applied over stretchable conductive-fabric materials to realize soft and wearable pressure sensors through ...

11

Electrode fabrication and interface optimization for imaging of evoked peripheral nervous system activity with electrical impedance tomography (EIT)

Electrode fabrication and interface optimization for imaging of evoked peripheral nervous system activity with electrical impedance tomography (EIT)

... amplifier system (ActiChamp) ...absolute impedance traces through the application of a 3rd order bandpass filter followed by a Hilbert transform resulting in the modulated envelope of the injected sine ...

12

Optimization of the centre ground method of Electrical Impedance Tomography System

Optimization of the centre ground method of Electrical Impedance Tomography System

... EIT system based on the common ground method of injection which includes finding the optimum value of current and frequency which gives good ...EIT system is also capable of detecting multiple objects of ...

7

A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System

A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System

... EIT imaging in the torso, with little emphasis placed on capturing the data required for EIT imaging of the ...thoracic imaging make translation to EIT of brain function ...continuous ...

20

LabVIEW based Automatic Data acquisition
          system for Electrical Impedance Tomography

LabVIEW based Automatic Data acquisition system for Electrical Impedance Tomography

... differential imaging methods, current is applied at a single frequency. Impedance of biological tissues is not purely resistive but they also exhibit a reactance component, due to the cell ...EIT ...

5

Design and Development of a Microscopic Electrical Impedance Tomography System

Design and Development of a Microscopic Electrical Impedance Tomography System

... Basically, Electrical impedance tomography is a new technique in monitoring and imaging cross sectional images and physical state of objects by measuring the internal impedance ...

5

Electrical impedance tomography imaging using a priori ultrasound data

Electrical impedance tomography imaging using a priori ultrasound data

... EIT system would sense the whole volume but the bound- aries of the ice ball would be difficult to accurately deter- ...cheaper system uses a few individual ultrasound transducers placed around the ...

8

A Novel Framework for Head Imaging with Electrical Impedance Tomography

A Novel Framework for Head Imaging with Electrical Impedance Tomography

... Multigrid algorithms are very effective for solving systems of discretised partial differential equations, and are based on the idea to support the convergence of the full problem by repeatedly adding a correction of the ...

166

Three Dimensional Electrical Impedance Tomography

Three Dimensional Electrical Impedance Tomography

... the imaging capabilities of EIT, as the electric currents used to determine the conductivity variations will not in general be confined to a two-dimensional plane ...EIT system with greatly improved ...

7

Multifrequency methods for Electrical Impedance Tomography

Multifrequency methods for Electrical Impedance Tomography

... EIT system had a ring of 16 electrodes, and a single current source ...for imaging conductivity changes in a 2D cross-section, the so-called "Sheffield algorithm", was based on a backprojection ...

170

Electrical impedance imaging system using FPGAs for flexibility and interoperability

Electrical impedance imaging system using FPGAs for flexibility and interoperability

... EIT system to the ...Mark1 system to 100 frames/sec in the ...Mark2.5 system now provides versatile functions such as reconfiguration of channels, automatic calibration, arbitrary current injection ...

14

In vivo bioimpedance changes during haemorrhagic and ischaemic stroke in rats: Towards 3D stroke imaging using electrical impedance tomography

In vivo bioimpedance changes during haemorrhagic and ischaemic stroke in rats: Towards 3D stroke imaging using electrical impedance tomography

... computed tomography (CT) or magnetic resonance imaging (MRI) ...centres. Electrical impedance tomography (EIT) has the potential to provide an inexpensive portable unit for use in ...

21

Electrical Impedance Tomography of human brain function

Electrical Impedance Tomography of human brain function

... Realistic anatomical a p rio ri information was included in the inverse problem by Vauhkonen (1997) and Vauhkonen et al. (1997), in their basis constraint method. A number o f example conductivity distributions (the ...

296

Hematocrit level correlates with lungs resistivity in elderly patients with cardiogenic pulmonary edema

Hematocrit level correlates with lungs resistivity in elderly patients with cardiogenic pulmonary edema

... BioZ system (CardioDynamics, San Diego, CA) that extracts thoracic fluid content and additional hemodynamic and cardiac parameters ...thoracic impedance, and the rela- tive contributions of the various ...

6

Electrical Impedance Based Spectroscopy and Tomography Techniques for Obesity and Heart Diseases

Electrical Impedance Based Spectroscopy and Tomography Techniques for Obesity and Heart Diseases

... that electrical impedance spectroscopy (EIS) technique can be useful to effectively distinguish plaques with such lipid ...The impedance modulus over 200 Hz-100 KHz show consistent elevated values ...

188

Low Frequency Bio-Electrical Impedance Mammography and Dielectric Measurement

Low Frequency Bio-Electrical Impedance Mammography and Dielectric Measurement

... angle imaging) a series of computer simulations were carried out on a phantom following the configuration shown in Figure ...the impedance values of the breast tissue located between each detector cell and ...

144

Electrical impedance tomography in acute respiratory distress syndrome

Electrical impedance tomography in acute respiratory distress syndrome

... regional impedance–time curves, the delay time was estimated between the begin- ning of the inspiration until the slope of the impedance/ time curve reached a certain percentage of the inspira- tory time in ...

11

New Solutions for the Three-Dimensional Electrical Impedance Equation and its Application to the Electrical Impedance Tomography Theory

New Solutions for the Three-Dimensional Electrical Impedance Equation and its Application to the Electrical Impedance Tomography Theory

... Since for all physical cases the boundary is a closed curve or a closed surface, the function u j could be represented using quite standard expansions, such as the Fourier series. Hence, the Neural Network might be ...

6

Real time reconstruction of log cross sections using tomographic data : a thesis presented in fulfilment of the requirements for the degree of Doctor of Philosophy at Massey University

Real time reconstruction of log cross sections using tomographic data : a thesis presented in fulfilment of the requirements for the degree of Doctor of Philosophy at Massey University

... The third generation scanners (known as 'rotate-rotate' scanners) developed in the early 80's employed a system where both the single source and the array of detectors are rotated around the object over 360 ...

239

Adaptive mesh refinement techniques for electrical impedance tomography

Adaptive mesh refinement techniques for electrical impedance tomography

... Electrical impedance tomography (EIT) can provide images with well defined characteristics only when the full nonlinear reconstruction process is constrained by a property of the image such as its ...

6

Show all 10000 documents...

Related subjects