• No results found

Harmonic Compensation,

Harmonic Compensation using Coordinated Control of Dual Interfacing Converters at Microgrid

Harmonic Compensation using Coordinated Control of Dual Interfacing Converters at Microgrid

... voltage harmonic mitigation. There arise current harmonic due to the interaction between the first interfacing converter and the local nonlinear ...current harmonic compensation that resulted ...

6

HARMONIC COMPENSATION USING FUZZY CONTROLLED DSTATCOM

HARMONIC COMPENSATION USING FUZZY CONTROLLED DSTATCOM

... The design of FLCs for a DSTATCOM to improve power quality and dynamic performance of a distribution power system has done. FLC has to be designed for the DC voltage regulator, the AC voltage regulator, and the current ...

8

Performance analysis 
		of active power filter for harmonic compensation using PI PSO

Performance analysis of active power filter for harmonic compensation using PI PSO

... A PSO-based algorithm was developed to search for the optimal solution. The numerical results of case studies comparing the PSO method and the conventional method are reported. The PSO technique is found to offer better ...

7

Harmonic Compensation Design with Multi-level Inverter

Harmonic Compensation Design with Multi-level Inverter

... generate harmonic current, which reduces the quality of power as stated in ...The harmonic currents may result in voltage harmonics. The compensation of load current harmonics is usually carried out ...

8

Grid Voltage and Current Harmonic Compensation using Fuzzy Logic Based Coordinated Controller

Grid Voltage and Current Harmonic Compensation using Fuzzy Logic Based Coordinated Controller

... dynamic harmonic separating ...the harmonic separating execution of DG interfacing converters that are associated with a grid with substantial variety of grid ...mentioned compensation strategies are ...

12

CURRENT HARMONIC COMPENSATION IN THE ELECTRICAL NETWORK USING VOLTAGE SHUNT ACTIVE FILTER CONTROLLED BY HYSTERISIS Abdelhamid HMIDAT *1 Abdelhadi ELMOUDDEN 2Jamal BOUKHEROUAA3 Abdelmajid BERDAI 4Abdelaziz BELFQIH5 Faissal EL MARIAMI 6Abdallah SAAD7

CURRENT HARMONIC COMPENSATION IN THE ELECTRICAL NETWORK USING VOLTAGE SHUNT ACTIVE FILTER CONTROLLED BY HYSTERISIS Abdelhamid HMIDAT *1 Abdelhadi ELMOUDDEN 2Jamal BOUKHEROUAA3 Abdelmajid BERDAI 4Abdelaziz BELFQIH5 Faissal EL MARIAMI 6Abdallah SAAD7

... We then provided the results of the simulation for a polluting load of 400KVA. These results show a good compensation of current harmonics and a good reduction of total harmonic distortion (from 29% before ...

14

Challenges with Harmonic Compensation at a Remote Bus in Offshore Wind Power Plant

Challenges with Harmonic Compensation at a Remote Bus in Offshore Wind Power Plant

... of the harmonic filtering resistance connected at two different buses are numerically analyzed using. 145[r] ...

17

Synchronous Reference Frame Based Hybrid Shunt Filter for Current Harmonic Compensation

Synchronous Reference Frame Based Hybrid Shunt Filter for Current Harmonic Compensation

... for compensation of current and/or voltage harmonics originated by non-linear loads, or to avoid those harmonic voltages that might be effect operation of sensitive ...

5

SIMULINK DESIGN OF SAPF FOR HARMONIC CURRENT AND REACTIVE POWER COMPENSATION

SIMULINK DESIGN OF SAPF FOR HARMONIC CURRENT AND REACTIVE POWER COMPENSATION

... simultaneous compensation of voltage, current harmonics and reactive ...APF compensation performance, also the minimization of cost and complexity of compensation ...

6

Alleviation of Lower Order Harmonics in a Single Phase Photo Voltaic Inverter Connected To Grid

Alleviation of Lower Order Harmonics in a Single Phase Photo Voltaic Inverter Connected To Grid

... adaptive compensation is shown in ...the harmonic compensation block uses the secondary current, which is the current injected into the ...adaptive harmonic compensation block for the k ...

8

Power Quality Improvement using Shunt Hybrid Power Filter (SHPF) and Thyristor Controlled Reactor (TCR)

Power Quality Improvement using Shunt Hybrid Power Filter (SHPF) and Thyristor Controlled Reactor (TCR)

... for harmonic compensation and power factor correction and the objective of the active filter is isolate the system impedance from the filter impedance to avoid ...the compensation characteristics of ...

10

Reactive Power Compensation Capability and Active Power Transfer of PMSG Based Variable Speed WECS

Reactive Power Compensation Capability and Active Power Transfer of PMSG Based Variable Speed WECS

... The grid side converter is an inverter, which convert dc to ac and then it is transferred to grid. The main objective of grid side converter is to deliver captured power with required reactive power compensation ...

9

A Novel to Reduce Harmonics using Conventional Control of Active Shunt Power Filter

A Novel to Reduce Harmonics using Conventional Control of Active Shunt Power Filter

... how Harmonic distortion is one of the critical problems associated with power quality and creates several disturbances to the Power ...the Harmonic reduction techniques to improve the power quality and it ...

6

Mitigation of Lower Order Harmonics in a Grid Connected Single Phase Pv-Inverter by Fuzzy Controller

Mitigation of Lower Order Harmonics in a Grid Connected Single Phase Pv-Inverter by Fuzzy Controller

... adaptive harmonic compensation technique and its design are proposed for the lower order harmonic compensation The proposed method uses an LMS adaptive filter to estimate a particular ...

5

Index Terms: Active power filter (APF), cascaded multilevel inverter, close-loop control, feed forward of fundamental load current I INTRODUCTION

Index Terms: Active power filter (APF), cascaded multilevel inverter, close-loop control, feed forward of fundamental load current I INTRODUCTION

... the harmonic pollution in electrical ...selective harmonic compensation in order to cancel the line current ...traditional compensation methods such as passive filters used have many ...

7

MODELING AND DESIGN OF SINGLE PHASE PV INVERTER FOR HARMONIC MITIGATION

MODELING AND DESIGN OF SINGLE PHASE PV INVERTER FOR HARMONIC MITIGATION

... order harmonic injection are identified as the distorted transformer a centralizing current and the dead time of the ...particular harmonic in the grid current that needs to be ...adequate harmonic ...

6

Islanding and Seamless Reconnection of Multiple Solid-State Transformers Based On Droop Control

Islanding and Seamless Reconnection of Multiple Solid-State Transformers Based On Droop Control

... To improve the stability of the multi-loop controller at its fundamental frequency, a novel virtual impedance method is also proposed which fits to the multi-loop structure. Although the virtual impedance method is ...

212

A fuzzy controlled STATCOM for 
		compensation of SEIG feeding single phase harmonic load

A fuzzy controlled STATCOM for compensation of SEIG feeding single phase harmonic load

... the harmonic content in source current and power factor at point of common coupling (PCC) when a single-phase non-linear load fed from wind generator with PI and fuzzy controlled STATCOM at ...for harmonic ...

7

Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure

Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure

... power compensation, reactive power hybrid filters consisting of active and passive filters are ...in harmonic elimination and reactive power ...desired harmonic level regarding the conventional ...

8

Based on the Research of Ball Mill Reactive Power Compensation Device and Harmonic Current

Based on the Research of Ball Mill Reactive Power Compensation Device and Harmonic Current

... reactive compensation capacity is proportional to the square of the supply voltage, and more serious is that it can influence each other between it and the ...the harmonic currents, so the ...

6

Show all 4724 documents...