Development of a reference Phasor Measurement Unit (PMU) for the monitoring and control of grid stability and quality

Development of a reference Phasor Measurement Unit (PMU) for the monitoring and control of grid stability and quality

... We emphasized this paper on the topic of phasor measurement unit (PMU), since it is an essential device for monitoring and control of grid stability and quality. We presented here some of the ...

5

State estimation by use of WLS state technique and Phasor measurement unit

State estimation by use of WLS state technique and Phasor measurement unit

... A phasor measurement unit (PMU) (Aminifar et ...synchronised phasor measurements of voltages and currents from widely isolated locations in an electric power ...

11

WIDE AREA MEASUREMENT USING PHASOR MEASUREMENT UNIT

WIDE AREA MEASUREMENT USING PHASOR MEASUREMENT UNIT

... ideal measurement system for protection, monitor and controlling wide power system networks voltages and currents using phasor measurement ...

6

Optimal Placement of Phasor Measurement Unit  Using Ant Colony Optimization

Optimal Placement of Phasor Measurement Unit Using Ant Colony Optimization

... After all ants finish their tours (each tour corresponds to a PMU placement), these tours (PMU placements) are evaluated by the number of observed buses by the action of these placements. The best tour which gives the ...

11

P and M class phasor measurement unit algorithms using adaptive cascaded filters

P and M class phasor measurement unit algorithms using adaptive cascaded filters

... HASOR measurement units (PMUs) are being deployed in ever increasing numbers. They can be used to determine system instability [1, 2], detect disconnected lines and islanded sections [3], aid in power system ...

14

P-class phasor measurement unit algorithms using adaptive filtering to enhance accuracy at off-nominal frequencies

P-class phasor measurement unit algorithms using adaptive filtering to enhance accuracy at off-nominal frequencies

... The new standard describes “Basic” reference algorithms for P-class (protection) and M-class (measurement) devices, which are claimed to meet the requirements. This paper explores the behaviour of the “Basic” P ...

8

High Impedance Fault Detection of Distribution Network by Phasor Measurement Units

High Impedance Fault Detection of Distribution Network by Phasor Measurement Units

... This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because ...

9

Article Description

Article Description

... A phasor is a complex number associated with a sinusoidal wave. The phasor magnitude is the same as the sinusoidal wave ...The phasor phase angle is the phase of the wave at t = ...synchronized ...

5

Impact of Earnings per Share on Market Price of Share with Special Reference to Selected Companies Listed on NSE

Impact of Earnings per Share on Market Price of Share with Special Reference to Selected Companies Listed on NSE

... algorithm-based Phasor measurement unit placement method considering observ ability and security ..."Phasor Measurement Unit (PMU) Implementation andApplications (DOCID ...

8

Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units

Improving frequency and ROCOF accuracy during faults, for P class Phasor Measurement Units

... of Phasor Measurement Unit (PMU) performance are tested using the existing (and evolving) IEEE ...system measurement, control and response is ...

6

Optimal Placement of Phasor Measurement Units using Integer Linear Programming

Optimal Placement of Phasor Measurement Units using Integer Linear Programming

... PHASOR Measurement Unit (PMU) was introduced in ...Synchronized phasor measurements have took the power system monitoring, control, and protection to a new level ...

6

Wide Area Monitoring, Protection and Control (WAMPAC) Application in Transmission Grid A Literature Review

Wide Area Monitoring, Protection and Control (WAMPAC) Application in Transmission Grid A Literature Review

... Pradeep & Singh (2014) presented the Phasor Measurement Unit (PMU) is an important tool for monitoring and control of the power system. The model gives real time, synchronized measurements of ...

10

Minimising the impact of disturbances in future highly-distributed power systems

Minimising the impact of disturbances in future highly-distributed power systems

... Wide-area phasor measurement unit (PMU) monitoring schemes are being utilised to enable new system functions, such as fast-acting frequency control [5] distributed control paradigms [6], and will ...

6

Fast Initial State Assessment for State Estimator using Optimally Located Phasor Measurement Units

Fast Initial State Assessment for State Estimator using Optimally Located Phasor Measurement Units

... A Phasor Measurement Unit (PMU) measures the voltage and current phasors (angle and magnitude) at a bus in a power ...a measurement set for the allocation of ...

5

Filters for M class phasor measurement units

Filters for M class phasor measurement units

... for phasor measurement units (PMUs) under steady-state and dynamic ...class Phasor Measurement Unit (PMU) algorithm is presented, and in particular a completely different design of M ...

8

The amended standard C37.118.1a and its implications for frequency-tracking M-class phasor measurement units (PMUs)

The amended standard C37.118.1a and its implications for frequency-tracking M-class phasor measurement units (PMUs)

... However, the main focus of this paper is on the updated requirements for the bandwidth and Out-Of-Band interference (OOB) tests, and the implications for M-class Phasor Measurement Unit (PMU) design. ...

6

Parameter Estimation of Smart Grid using PMU with Kalman Filter and Bayesian Prediction

Parameter Estimation of Smart Grid using PMU with Kalman Filter and Bayesian Prediction

... A phasor measurement unit was used for analysing and controlling the energy system by measurement of voltage phase in transmission lines and electrical ...

9

PMU based Protection for 14-Bus Transmission SystemRanjitha R, Sulochana I Akkalkot, Prakash R, Anguraja R

PMU based Protection for 14-Bus Transmission SystemRanjitha R, Sulochana I Akkalkot, Prakash R, Anguraja R

... using Phasor measurement units (PMUs) as an alternative for distribution backup protection in ...and measurement principles have promoted the advent of phasor measurement units ...of ...

5

Implementation of Frequency and Phasor Measurement of Input AC Signal on FPGA

Implementation of Frequency and Phasor Measurement of Input AC Signal on FPGA

... synchrophasor measurement in power systems and describes various requirements for synchronized ...measurement. Phasor Measurement Unit (PMU) is a device that estimates synchrophasor, ...

6

Evaluation of power system Oscillation with the use of Phasor Measurement Technology (PMU) and its Damping with use of Power System Stabilizer (PSS)

Evaluation of power system Oscillation with the use of Phasor Measurement Technology (PMU) and its Damping with use of Power System Stabilizer (PSS)

... “Phasor measurement unit (PMU) device is measure the electric waves on an electricity grid, using common time source for ...real-time measurement of multiple remote measurement points ...

9

Show all 10000 documents...