• No results found

power converter input filter

Indirect predictive control strategy with mitigation of input filter resonances for a direct matrix converter

Indirect predictive control strategy with mitigation of input filter resonances for a direct matrix converter

... the converter at every sampling ...active power filters [7], PWM rectifiers [8], permanent magnet machines [9], as well as matrix converters [10]–[12] among ...

6

Indirect model predictive control strategies with input filter resonance mitigation for a matrix converter operating at fixed switching frequency

Indirect model predictive control strategies with input filter resonance mitigation for a matrix converter operating at fixed switching frequency

... both input and output stages of the converter, being possible to reduce the complexity of the control, the operation at fixed switching frequency but also avoid the calculation of a weighting ...reactive ...

6

A high power factor rectifier based on buck converter operating in discontinuous inductor current mode

A high power factor rectifier based on buck converter operating in discontinuous inductor current mode

... The goal of this paper is to give a more comprehensive analysis of Buck converter with the LC input filter oper- ating in DICM. In section 2 of this paper, the principle of DICM is analyzed. Based on ...

9

Power Quality Improvement in Distribution System by Using Novel Isolated Multi Level Dc to Dc Power Converter

Power Quality Improvement in Distribution System by Using Novel Isolated Multi Level Dc to Dc Power Converter

... the power electronic devices, S 1 and S 2 , are out of phase, and the frequency of the gate signal for S 3 is twice that of the gate signal for S 1 and S ...DC-DC power converter wherein the voltage ...

11

A simple current control strategy for a four leg indirect matrix converter

A simple current control strategy for a four leg indirect matrix converter

... complex power converters topologies such as matrix converters ...reactive power minimization has been proposed for both the three-phase direct and indirect matrix converter, which has been evaluated ...

13

Dual Switch Forward & Flyback Converter: A Comparison

Dual Switch Forward & Flyback Converter: A Comparison

... between input and output in the one step. Derived from the simple buck converter, the forward converter delivers energy from the input source to the output filter inductor during the on ...

5

COMPARATIVE STUDY OF DC-DC CONVERTERS FOR RECTIFIER POWER FACTOR CONTROL

COMPARATIVE STUDY OF DC-DC CONVERTERS FOR RECTIFIER POWER FACTOR CONTROL

... AC-DC converter becomes mandatory for such applications. . The input stage of AC-DC converter comprises of a full-bridge rectifier followed by a large filter ...The input current of ...

7

On Analysis of Front End Current of Rectifier Converter for low THD and high PF with SEPIC

On Analysis of Front End Current of Rectifier Converter for low THD and high PF with SEPIC

... the power electronic equipments are operated with dc ...rectifiers input currents are non sinusoidal in ...rectifier converter leads to low power factor, high THD, distribution system losses, ...

6

Analysis and modeling of buck converter in discontinuous output inductor current mode operation

Analysis and modeling of buck converter in discontinuous output inductor current mode operation

... Buck converter with LC input filter operating in discontinuous output current mode has a high power factor with a constant duty ...Buck converter in this operation mode can reduce the ...

8

DC-to-DC converter with low input current ripple for maximum photovoltaic power extraction

DC-to-DC converter with low input current ripple for maximum photovoltaic power extraction

... continuous input energy flow are widely used for renewable energy applications ...continuous input and output current to provide maximum energy flow from the source to the ...LC filter, a large ...

8

PFC CUK Converter for BLDC Motor Drives

PFC CUK Converter for BLDC Motor Drives

... PFC converter for the speed control of a ...dc–dc converter is used as a PFC converter because of its continuous input and output currents, small output filter, and wide output voltage ...

11

A High Power Factor Rectifier Based on Buck Converter Operating in Discontinuous Inductor Current Mode

A High Power Factor Rectifier Based on Buck Converter Operating in Discontinuous Inductor Current Mode

... The goal of this paper is to give a more comprehensive analysis of Buck converter with the LC input filter oper- ating in DICM. In section 2 of this paper, the principle of DICM is analyzed. Based on ...

8

LINEARIZATION OF CASCADED BUCK CONVERTER

LINEARIZATION OF CASCADED BUCK CONVERTER

... the input filters of the ...the input filter of a closed loop converter is analogous to the instability caused by the CPL loaded to a ...

13

Investigation of Harmonic Content and Power Factor Improvement for Single Phase AC-DC Converter Topologies

Investigation of Harmonic Content and Power Factor Improvement for Single Phase AC-DC Converter Topologies

... AC input to the Stator of the ...DC input to the Inverter is obtained from an AC/DC converter (preferably Three Phase ...[1] Input Current is distorted. In such cases Power Factor ...

15

Analysis and Modeling of Buck Converter in  Discontinuous Output Inductor Current  Mode Operation

Analysis and Modeling of Buck Converter in Discontinuous Output Inductor Current Mode Operation

... Buck converter with LC input filter operating in discontinuous output current mode has a high power factor with a constant duty ...Buck converter in this operation mode can reduce the ...

7

Integrated Off Line Ballast for High Brightness LEDs with Dimming Capability

Integrated Off Line Ballast for High Brightness LEDs with Dimming Capability

... The first thing to settle is the target load and its nominal operation point. In this case, a 32 W assembly of Power LEDs will be the target load. The selected device is the Luxeon LXK2-PW14-U00, from Lumileds ...

14

Stability Analysis in Positive Output and Negative Output DC to DC Converters Used in Renewable Energy Applications

Stability Analysis in Positive Output and Negative Output DC to DC Converters Used in Renewable Energy Applications

... the power electronic converter, the behavior of the system does not remain the same when the system parameter ...and input voltage of the converter, the system loses the fundamental operation ...

11

Vol 5, No 5 (2017)

Vol 5, No 5 (2017)

... Active Filter (SAPF) is the bidirectional current converter with six switches having combination of both switching network and ...this power filter is dependent on the control technique of VSI ...

7

Power Factor Correction Using SEPIC AC-DC Converter

Power Factor Correction Using SEPIC AC-DC Converter

... boost converter which has a simple topology in terms of power and control views ...difficult input-out high frequency isolation, output voltage higher than the peak input voltage, high ...

6

Simulation of Shunt Active Filter for Compensation  of Nonlinear Load Currents

Simulation of Shunt Active Filter for Compensation of Nonlinear Load Currents

... of power electronic device in power system creates pollution issues in the ...the power quality issues is power system are due to the use of nonlinear loads as they introduce current harmonics ...

7

Show all 10000 documents...